Acute Phase Response and Non-Reproducible Elevated Concentrations with a High-Sensitivity Cardiac Troponin I Assay

被引:17
|
作者
Kavsak, Peter A. [1 ,2 ,3 ]
Clark, Lorna [2 ,3 ]
Martin, Janet [1 ]
Mark, Ching-Tong [2 ,3 ]
Pare, Guillaume [1 ]
Mondoux, Shawn [4 ]
Chetty, V. Tony [1 ]
Ainsworth, Craig [5 ]
Worster, Andrew [4 ]
机构
[1] McMaster Univ, Dept Pathol & Mol Med, Hamilton, ON L8S 4L8, Canada
[2] Hamilton Hlth Sci, Core Lab, Juravinski Hosp, Hamilton, ON L8V 1C3, Canada
[3] Hamilton Hlth Sci, Canc Ctr, Hamilton, ON L8V 1C3, Canada
[4] McMaster Univ, Dept Med, Div Emergency Med, Hamilton, ON L8S 4L8, Canada
[5] McMaster Univ, Dept Med, Div Cardiol, Hamilton, ON L8S 4L8, Canada
基金
加拿大健康研究院;
关键词
high-sensitivity cardiac troponin I; myocardial injury; analytical error; interferences; UPPER REFERENCE LIMITS;
D O I
10.3390/jcm10051014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High-sensitivity cardiac troponin (hs-cTn) testing has enabled physicians to make earlier diagnostic and prognostic decisions in the hospital setting than previous cardiac troponin assays. Analytical improvements have permitted one to measure cardiac troponin precisely in the nanogram per litre (ng/L) range with hs-cTn assays which has resulted in fast 0/1-h and 0/2-h algorithms for ruling-in and ruling-out myocardial infarction. Although analytical interferences that affect the reporting of hs-cTn are uncommon, not all hs-cTn assays are designed the same nor have undergone the same clinical and analytical validations. Here, after investigating an initial case of discrepant hs-cTnI results, we report that patients with an acute phase response (e.g., patients with inflammatory or infectious illnesses) can yield high and non-reproducible results with the Ortho Clinical Diagnostics hs-cTnI assay. Compared to Abbott Diagnostics hs-cTnI, Ortho Clinical Diagnostics hs-cTnI assay misclassifies biochemical injury in approximately 10% of the population being assessed for myocardial injury with imprecise results in approximately half of this population (i.e., 5%). In conclusion, caution is warranted in interpreting Ortho Clinical Diagnostics hs-cTnI alone in patients being evaluated for myocardial injury, especially in patients whose primary presentation is related to an acute phase response and not an acute coronary syndrome symptom.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [21] High incidence of macrotroponin I with a high-sensitivity troponin I assay
    Warner, Janet V.
    Marshall, George A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (11) : 1821 - 1829
  • [22] Clinical Validation of a Novel High-Sensitivity Cardiac Troponin I Assay for Early Diagnosis of Acute Myocardial Infarction
    Boeddinghaus, Jasper
    Twerenbold, Raphael
    Nestelberger, Thomas
    Badertscher, Patrick
    Wildi, Karin
    Puelacher, Christian
    de Lavallaz, Jeanne du Fay
    Keser, Elif
    Gimenez, Maria Rubini
    Wussler, Desiree
    Kozhuharov, Nikola
    Rentsch, Katharina
    Miro, Oscar
    Martin-Sanchez, F. Javier
    Morawiec, Beata
    Stefanelli, Sabrina
    Geigy, Nicolas
    Keller, Dagmar I.
    Reichlin, Tobias
    Mueller, Christian
    CLINICAL CHEMISTRY, 2018, 64 (09) : 1347 - 1360
  • [23] Diagnostic Performance of a Novel High-sensitivity Cardiac Troponin I Assay: The Westcor Study
    Tjora, Hilde Lunde L.
    Steiro, Ole-Thomas
    Langorgen, Jorund
    Nygard, Ottar K.
    Bjorneklett, Rune O.
    Renate, Renstrom
    Skadberg, Oyvind
    Bonarjee, Vernon V. S. V.
    Hunt, Clare
    Collinson, Paul
    Omland, Torbjorn
    Vikenes, Kjell
    Aakre, Kristin Moberg
    CIRCULATION, 2019, 140
  • [24] Evaluation of a high-sensitivity assay for measurement of canine and feline serum cardiac troponin I
    Langhorn, Rebecca
    Willesen, Jakob Lundgren
    Tarnow, Inge
    Kjelgaard-Hansen, Mads
    VETERINARY CLINICAL PATHOLOGY, 2013, 42 (04) : 490 - 498
  • [25] DETERMINANTS OF HIGH-SENSITIVITY CARDIAC TROPONIN I CONCENTRATIONS IN PATIENTS WITH SUSPECTED STABLE ANGINA
    Adamson, Philip D.
    Henderson, James
    Hunter, Amanda
    Williams, Michelle
    Moss, Alastair J.
    Shah, Anoop
    McAllister, David A.
    Dweck, Marc R.
    Mills, Nicholas
    Newby, David
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 104 - 104
  • [26] Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay
    Kaysak, Peter A.
    MacCuish, Jackie
    Boreyko, Jill
    Roy, Chantele
    Lamers, Shana
    Clark, Lorna
    CLINICAL BIOCHEMISTRY, 2019, 69 : 52 - 56
  • [27] High-sensitivity cardiac troponin I: is ethnicity relevant?
    Kalaria, Tejas R.
    Harris, Nicola
    Sensi, Harminder
    Valentine, Ross
    Asif, Usama
    Sharrod-Cole, Hayley
    Coley-Grant, Deon
    Min, San San
    Ford, Clare
    Gama, Rousseau
    JOURNAL OF CLINICAL PATHOLOGY, 2021, 74 (11) : 709 - 711
  • [28] Analytical and clinical performance evaluation of a new high-sensitivity cardiac troponin I assay
    Yang, Shuo
    Zhang, Qian
    Yang, Boxin
    Li, Zijing
    Sun, Wenyuan
    Cui, Liyan
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (08) : 1299 - 1307
  • [29] Detection of repeated positive result biases for a high-sensitivity cardiac troponin I assay
    Kavsak, Peter A.
    Caruso, Nadia
    Mark, Ching-Tong
    Millar, Elspeth
    Clark, Lorna
    CLINICA CHIMICA ACTA, 2020, 510 : 242 - 243
  • [30] Analytical assessment of ortho clinical diagnostics high-sensitivity cardiac troponin I assay
    Kavsak, Peter A.
    Edge, Tara
    Roy, Chantele
    Malinowski, Paul
    Bamford, Karen
    Clark, Lorna
    Lamers, Shana
    Hill, Stephen
    Worster, Andrew
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (04) : 749 - 755