Acute Phase Response and Non-Reproducible Elevated Concentrations with a High-Sensitivity Cardiac Troponin I Assay

被引:17
|
作者
Kavsak, Peter A. [1 ,2 ,3 ]
Clark, Lorna [2 ,3 ]
Martin, Janet [1 ]
Mark, Ching-Tong [2 ,3 ]
Pare, Guillaume [1 ]
Mondoux, Shawn [4 ]
Chetty, V. Tony [1 ]
Ainsworth, Craig [5 ]
Worster, Andrew [4 ]
机构
[1] McMaster Univ, Dept Pathol & Mol Med, Hamilton, ON L8S 4L8, Canada
[2] Hamilton Hlth Sci, Core Lab, Juravinski Hosp, Hamilton, ON L8V 1C3, Canada
[3] Hamilton Hlth Sci, Canc Ctr, Hamilton, ON L8V 1C3, Canada
[4] McMaster Univ, Dept Med, Div Emergency Med, Hamilton, ON L8S 4L8, Canada
[5] McMaster Univ, Dept Med, Div Cardiol, Hamilton, ON L8S 4L8, Canada
基金
加拿大健康研究院;
关键词
high-sensitivity cardiac troponin I; myocardial injury; analytical error; interferences; UPPER REFERENCE LIMITS;
D O I
10.3390/jcm10051014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High-sensitivity cardiac troponin (hs-cTn) testing has enabled physicians to make earlier diagnostic and prognostic decisions in the hospital setting than previous cardiac troponin assays. Analytical improvements have permitted one to measure cardiac troponin precisely in the nanogram per litre (ng/L) range with hs-cTn assays which has resulted in fast 0/1-h and 0/2-h algorithms for ruling-in and ruling-out myocardial infarction. Although analytical interferences that affect the reporting of hs-cTn are uncommon, not all hs-cTn assays are designed the same nor have undergone the same clinical and analytical validations. Here, after investigating an initial case of discrepant hs-cTnI results, we report that patients with an acute phase response (e.g., patients with inflammatory or infectious illnesses) can yield high and non-reproducible results with the Ortho Clinical Diagnostics hs-cTnI assay. Compared to Abbott Diagnostics hs-cTnI, Ortho Clinical Diagnostics hs-cTnI assay misclassifies biochemical injury in approximately 10% of the population being assessed for myocardial injury with imprecise results in approximately half of this population (i.e., 5%). In conclusion, caution is warranted in interpreting Ortho Clinical Diagnostics hs-cTnI alone in patients being evaluated for myocardial injury, especially in patients whose primary presentation is related to an acute phase response and not an acute coronary syndrome symptom.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] Postmortem Analysis of Cardiac Troponin I by High-Sensitivity Troponin I Assay
    Hafiz, W. R. Wan Mohammad
    Aliaa, B. izzatul
    Swarhib, S. mohamed
    Faridah, M. N.
    MEDICINE AND HEALTH, 2025, 20 (01): : 328 - 339
  • [2] Diagnostic Validation of a High-Sensitivity Cardiac Troponin I Assay
    Soerensen, Nils A.
    Gossling, Alina
    Neumann, Johannes T.
    Hartikainen, Tau S.
    Haller, Paul M.
    Scharlemann, Lea
    Lehmacher, Jonas
    Ziegler, Andreas
    Blankenberg, Stefan
    Zeller, Tanja
    Nordholt, Gerhard
    Renne, Thomas
    Westermann, Dirk
    CLINICAL CHEMISTRY, 2021, 67 (09) : 1230 - 1239
  • [3] High-Sensitivity Cardiac Troponin I Assay for Early Diagnosis of Acute Myocardial Infarction
    Boeddinghaus, Jasper
    Nestelberger, Thomas
    Twerenbold, Raphael
    Koechlin, Luca
    Meier, Mario
    Troester, Valentina
    Wussler, Desiree
    Badertscher, Patrick
    Wildi, Karin
    Puelacher, Christian
    de Lavallaz, Jeanne du Fay
    Gimenez, Maria Rubini
    Zimmermann, Tobias
    Hafner, Benjamin
    Potlukova, Eliska
    Miro, Oscar
    Javier Martin-Sanchez, F.
    Keller, Dagmar, I
    Reichlin, Tobias
    Mueller, Christian
    Walter, Joan Elias
    Strebe, No
    Kozhuharov, Nikola
    Freese, Michael
    Fuenzalida, Carolina
    Stelzig, Claudia
    Gualandro, Danielle M.
    Michou, Eleni
    Meissner, Kathrin
    Kulangara, Caroline
    Shrestha, Samyut
    Fahrni, Regor
    Osswald, Stefan
    Lopez, Beatriz
    Rodriguez Adrada, Esther
    Ganovska, Eva
    Lohrmann, Jens
    Kloos, Wanda
    Steude, Jana
    User, Andreas B.
    von Eckardstein, Arnold
    Morawiec, Beata
    Kawecki, Damian
    Nowalany-Kozielska, Ewa
    Muzyk, Piotr
    Geigy, Nicolas
    Rentsch, Katharina
    CLINICAL CHEMISTRY, 2019, 65 (07) : 893 - 904
  • [4] Clinical performance of a new high-sensitivity cardiac troponin I assay
    Plebani, M.
    Mion, M.
    Novello, E.
    Zaninotto, M.
    Babuin, L.
    Iliceto, S.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A67 - A67
  • [5] Discordant High-Sensitivity Cardiac Troponin I Concentrations in the General Population
    Kavsak, Peter A.
    Ma, Jinhui
    CLINICAL CHEMISTRY, 2024, 70 (03) : 562 - 564
  • [6] Misclassification of Myocardial Injury by a High-Sensitivity Cardiac Troponin I Assay
    Kavsak, Peter A.
    Mondoux, Shawn
    Worster, Andrew
    Martin, Janet
    Tandon, Vikas
    Ainsworth, Craig
    Devereaux, P. J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2021, 37 (03)
  • [7] High-Sensitivity Cardiac Troponin I Assay to Screen for Acute Rejection in Patients With Heart Transplant
    Patel, Parag C.
    Hill, Douglas A.
    Ayers, Colby R.
    Lavingia, Bhavna
    Kaiser, Patricia
    Dyer, Adrian K.
    Barnes, Aliessa P.
    Thibodeau, Jennifer T.
    Mishkin, Joseph D.
    Mammen, Pradeep P. A.
    Markham, David W.
    Stastny, Peter
    Ring, W. Steves
    de Lemos, James A.
    Drazner, Mark H.
    CIRCULATION-HEART FAILURE, 2014, 7 (03) : 463 - U132
  • [8] Novel high-sensitivity cardiac troponin I assay in patients with suspected acute coronary syndrome
    Chapman, Andrew R.
    Fujisawa, Takeshi
    Lee, Kuan Ken
    Andrews, Jack Patrick
    Anand, Atul
    Sandeman, Dennis
    Ferry, Amy V.
    Stewart, Stacey
    Marshall, Lucy
    Strachan, Fiona E.
    Gray, Alasdair
    Newby, David E.
    Shah, Anoop S. V.
    Mills, Nicholas L.
    HEART, 2019, 105 (08) : 616 - 622
  • [9] A novel high-sensitivity cardiac troponin i assay for early diagnosis of acute myocardial infarction
    Boeddinghaus, J.
    Nestelberger, T.
    Twerenbold, R.
    Koechlin, L.
    Wussler, D.
    Badertscher, P.
    Puelacher, C.
    De Lavallaz, J. Du Fay
    Gimenez, M. Rubini
    Zimmermann, T.
    Miro, O.
    Martin-Sanchez, F. J.
    Keller, D. I.
    Reichlin, T.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1940 - 1940
  • [10] Repeat measurements on patient samples identifies unpredictable and poorly reproducible cardiac troponin results with a high-sensitivity cardiac troponin assay
    Drummond, Simone
    Mark, Ching-Tong
    Caruso, Nadia
    Clark, Lorna
    Kavsak, Peter A.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2021, 58 (06) : 677 - 679