Real-time physiological measurements of oxygen using a non-invasive self-referencing optical fiber microsensor

被引:26
|
作者
Ferreira, Fernando [1 ,2 ]
Luxardi, Guillaume [1 ]
Reid, Brian [1 ]
Ma, Li [1 ,3 ]
Raghunathan, VijayKrishna [4 ,5 ,6 ]
Zhao, Min [1 ,7 ]
机构
[1] Univ Calif Davis, Inst Regenerat Cures, Dept Dermatol, Davis, CA 95616 USA
[2] Univ Minho, Dept Biol, CBMA, Braga, Portugal
[3] Shanghai Skin Dis Hosp, Skin & Cosmet Res Dept, Shanghai, Peoples R China
[4] Univ Houston, Dept Basic Sci, Coll Optometry, Houston, TX USA
[5] Univ Houston, Ocular Surface Inst, Coll Optometry, Houston, TX USA
[6] Univ Houston, Dept Biomed Engn, Cullen Coll Engn, Houston, TX USA
[7] Univ Calif Davis, Inst Regenerat Cures, Dept Ophthalmol, Sacramento, CA 95817 USA
关键词
REACTIVE OXYGEN; EMBRYONIC-DEVELOPMENT; HYPOXIA; PROBE; FLUX; LUMINESCENCE; TEMPERATURE; DIFFUSION; SENSORS; GROWTH;
D O I
10.1038/s41596-019-0231-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reactive molecular oxygen (O-2) plays important roles in bioenergetics and metabolism and is implicated in biochemical pathways underlying angiogenesis, fertilization, wound healing and regeneration. Here we describe how to use the scanning micro-optrode technique (SMOT) to measure extracellular fluxes of dissolved O-2. The self-referencing O-2-specific micro-optrode (also termed micro-optode and optical fiber microsensor) is a tapered optical fiber with an O-2-sensitive fluorophore coated onto the tip. The O-2 concentration is quantified by fluorescence quenching of the fluorophore emission upon excitation with blue-green light. The micro-optrode presents high spatial and temporal resolutions with improved signal-to-noise ratio (in the picomole range). In this protocol, we provide step-by-step instructions for micro-optrode calibration, validation, example applications and data analysis. We describe how to use the technique for cells (Xenopus oocyte), tissues (Xenopus epithelium and rat cornea), organs (Xenopus gills and mouse skin) and appendages (Xenopus tail), and provide recommendations on how to adapt the approach to different model systems. The basic, user-friendly system presented here can be readily installed to reliably and accurately measure physiological O-2 fluxes in a wide spectrum of biological models and physiological responses. The full protocol can be performed in similar to 4 h. Oxygen plays key roles in bioenergetics, metabolism, signaling pathways and developmental biology. This protocol describes how to perform quantitative oxygen flux measurements on cells, ex vivo tissues and various model animals in vivo.
引用
收藏
页码:207 / 235
页数:29
相关论文
共 50 条
  • [1] Real-time physiological measurements of oxygen using a non-invasive self-referencing optical fiber microsensor
    Fernando Ferreira
    Guillaume Luxardi
    Brian Reid
    Li Ma
    VijayKrishna Raghunathan
    Min Zhao
    Nature Protocols, 2020, 15 : 207 - 235
  • [2] Self-referencing optrode technology for non-invasive real-time measurement of biophysical flux and physiological sensing
    Chatni, M. R.
    Porterfield, D. M.
    ANALYST, 2009, 134 (11) : 2224 - 2232
  • [3] Non-Invasive Self-Referencing Electrochemical Sensors for Quantifying Real-Time Biofilm Analyte Flux
    McLamore, E. S.
    Porterfield, D. M.
    Banks, M. K.
    BIOTECHNOLOGY AND BIOENGINEERING, 2009, 102 (03) : 791 - 799
  • [4] Self-referencing luminescent optrodes for non-invasive, real time measurement of extracellular flux
    McLamore, Eric S.
    Porterfield, D. Marshall
    Borgens, R. B.
    Banks, M. K.
    SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY VIII, 2011, 8025
  • [5] Non-invasive tools for measuring metabolism and biophysical analyte transport: self-referencing physiological sensing
    McLamore, Eric S.
    Porterfield, D. Marshall
    CHEMICAL SOCIETY REVIEWS, 2011, 40 (11) : 5308 - 5320
  • [6] A self-referencing biosensor for real-time monitoring of physiological ATP transport in plant systems
    Vanegas, Diana C.
    Clark, Greg
    Cannon, Ashley E.
    Roux, Stanley
    Chaturvedi, Prachee
    McLamore, Eric S.
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 37 - 44
  • [7] A self-referencing microelectrode for real time measurements of silver flux
    McLamore, E. S.
    Stensberg, M. C.
    Sepulveda, M. S.
    Zhang, W.
    Banks, M. K.
    Porterfield, D. M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (02): : 445 - 452
  • [8] Detection of extracellular oxygen fluxes from single cultured neurons using a non-invasive, self-referencing, oxygen microelectrode.
    Land, SC
    Sanger, RH
    Smith, PJS
    FASEB JOURNAL, 1997, 11 (03): : 2006 - 2006
  • [9] Non-invasive approaches to measuring respiratory patterns using a PtTFPP based, phase-lifetime, self-referencing oxygen optrode
    Porterfield, D. Marshall
    Rickus, Jenna L.
    Kopelman, Roaul
    SMART MEDICAL AND BIOMEDICAL SENSOR TECHNOLOGY IV, 2006, 6380
  • [10] Self-referencing fiber optic particle plasmon resonance sensing system for real-time biological monitoring
    Wu, Chin-Wei
    Chiang, Chang-Yue
    Chen, Chien-H Sing
    Chiang, Chung-Sheng
    Wang, Chih-To
    Chau, Lai-Kwan
    TALANTA, 2016, 146 : 291 - 298