Image quality improvement with deep learning-based reconstruction on abdominal ultrahigh-resolution CT: A phantom study

被引:14
|
作者
Shirasaka, Takashi [1 ]
Kojima, Tsukasa [1 ]
Funama, Yoshinori [2 ]
Sakai, Yuki [1 ]
Kondo, Masatoshi [1 ]
Mikayama, Ryoji [1 ]
Hamasaki, Hiroshi [1 ]
Kato, Toyoyuki [1 ]
Ushijima, Yasuhiro [3 ]
Asayama, Yoshiki [4 ]
Nishie, Akihiro [3 ]
机构
[1] Kyushu Univ Hosp, Dept Med Technol, Div Radiol, Fukuoka, Japan
[2] Kumamoto Univ, Dept Med Phys, Fac Life Sci, Kumamoto, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka, Japan
[4] Kyushu Univ, Grad Sch Med Sci, Dept Adv Imaging & Intervent Radiol, Fukuoka, Japan
来源
关键词
deep learning-based reconstruction; ultrahigh-resolution CT; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; PERFORMANCE; CONTRAST; CANCER;
D O I
10.1002/acm2.13318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In an ultrahigh-resolution CT (U-HRCT), deep learning-based reconstruction (DLR) is expected to drastically reduce image noise without degrading spatial resolution. We assessed a new algorithm's effect on image quality at different radiation doses assuming an abdominal CT protocol. Methods For the normal-sized abdominal models, a Catphan 600 was scanned by U-HRCT with 100%, 50%, and 25% radiation doses. In all acquisitions, DLR was compared to model-based iterative reconstruction (MBIR), filtered back projection (FBP), and hybrid iterative reconstruction (HIR). For the quantitative assessment, we compared image noise, which was defined as the standard deviation of the CT number, and spatial resolution among all reconstruction algorithms. Results Deep learning-based reconstruction yielded lower image noise than FBP and HIR at each radiation dose. DLR yielded higher image noise than MBIR at the 100% and 50% radiation doses (100%, 50%, DLR: 15.4, 16.9 vs MBIR: 10.2, 15.6 Hounsfield units: HU). However, at the 25% radiation dose, the image noise in DLR was lower than that in MBIR (16.7 vs. 26.6 HU). The spatial frequency at 10% of the modulation transfer function (MTF) in DLR was 1.0 cycles/mm, slightly lower than that in MBIR (1.05 cycles/mm) at the 100% radiation dose. Even when the radiation dose decreased, the spatial frequency at 10% of the MTF of DLR did not change significantly (50% and 25% doses, 0.98 and 0.99 cycles/mm, respectively). Conclusion Deep learning-based reconstruction performs more consistently at decreasing dose in abdominal ultrahigh-resolution CT compared to all other commercially available reconstruction algorithms evaluated.
引用
收藏
页码:286 / 296
页数:11
相关论文
共 50 条
  • [1] Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies
    Jeon, Pil-Hyun
    Jeon, Sang-Hyun
    Ko, Donghee
    An, Giyong
    Shim, Hackjoon
    Otgonbaatar, Chuluunbaatar
    Son, Kihong
    Kim, Daehong
    Ko, Sung Min
    Chung, Myung-Ae
    DIAGNOSTICS, 2023, 13 (11)
  • [2] Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study
    Joël Greffier
    Quentin Durand
    Julien Frandon
    Salim Si-Mohamed
    Maeliss Loisy
    Fabien de Oliveira
    Jean-Paul Beregi
    Djamel Dabli
    European Radiology, 2023, 33 : 699 - 710
  • [3] Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study
    Greffier, Joel
    Durand, Quentin
    Frandon, Julien
    Si-Mohamed, Salim
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean-Paul
    Dabli, Djamel
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 699 - 710
  • [4] Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics
    Higaki, Toru
    Nakamura, Yuko
    Zhou, Jian
    Yu, Zhou
    Nemoto, Takuya
    Tatsugami, Fuminari
    Awai, Kazuo
    ACADEMIC RADIOLOGY, 2020, 27 (01) : 82 - 87
  • [5] Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT
    Motonori Akagi
    Yuko Nakamura
    Toru Higaki
    Keigo Narita
    Yukiko Honda
    Jian Zhou
    Zhou Yu
    Naruomi Akino
    Kazuo Awai
    European Radiology, 2019, 29 : 6163 - 6171
  • [6] Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT
    Akagi, Motonori
    Nakamura, Yuko
    Higaki, Toru
    Narita, Keigo
    Honda, Yukiko
    Zhou, Jian
    Yu, Zhou
    Akino, Naruomi
    Awai, Kazuo
    EUROPEAN RADIOLOGY, 2019, 29 (11) : 6163 - 6171
  • [7] Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
    Greffier, Joel
    Hamard, Aymeric
    Pereira, Fabricio
    Barrau, Corinne
    Pasquier, Hugo
    Beregi, Jean Paul
    Frandon, Julien
    EUROPEAN RADIOLOGY, 2020, 30 (07) : 3951 - 3959
  • [8] Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
    Joël Greffier
    Aymeric Hamard
    Fabricio Pereira
    Corinne Barrau
    Hugo Pasquier
    Jean Paul Beregi
    Julien Frandon
    European Radiology, 2020, 30 : 3951 - 3959
  • [9] Radiation dose reduction and image quality improvement with ultra-high resolution temporal bone CT using deep learning-based reconstruction: An anatomical study
    Boubaker, Fatma
    Puel, Ulysse
    Eliezer, Michael
    Hossu, Gabriela
    Assabah, Bouchra
    Haioun, Karim
    Blum, Alain
    Gondim-Teixeira, Pedro Augusto
    Parietti-Winkler, Cecile
    Gillet, Romain
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (10) : 371 - 378
  • [10] Improved image quality in CT pulmonary angiography using deep learning-based image reconstruction
    Ann-Christin Klemenz
    Lasse Albrecht
    Mathias Manzke
    Antonia Dalmer
    Benjamin Böttcher
    Alexey Surov
    Marc-André Weber
    Felix G. Meinel
    Scientific Reports, 14