Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source

被引:25
|
作者
Medich, David C.
Munro, John J., III
机构
[1] Univ Massachusetts, Radiat Lab, Lowell, MA 01854 USA
[2] Source Prod & Equipment Co Inc, St Rose, LA 70087 USA
关键词
brachytherapy; iridium-192; radiation dosimetry; Monte Carlo; MCNP;
D O I
10.1118/1.2733809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The MCNP5 Monte Carlo code was used to simulate the dosimetry of an M-19 iridium-192 high dose rate brachytherapy source in both air/vacuum and water environments with the in-air photon spectrum filtered to remove low-energy photons below delta= 10 keV. Dosimetric data was organized into an away-along table and was used to derive the updated AAPM Task Group Report No. 43 (TG-43U1) parameters including S-K, D(r, theta), Lambda, g(L)(r), F(r, theta), phi(an)(r), and (phi) over bar (an) and their respective statistical uncertainties. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1999 / 2006
页数:8
相关论文
共 50 条
  • [41] Geometric Optimizations of a Directional High Dose Rate Brachytherapy Source Using Monte Carlo
    Heredia, A.
    Henderson, D.
    Thomadsen, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [42] Comparison of high-dose rate prostate brachytherapy dose distributions with iridium-192, ytterbium-169, and thulium-170 sources
    Krishnamurthy, Devan
    Weinberg, Vivian
    Cunha, J. Adam M.
    Hsu, I-Chow
    Pouliot, Jean
    BRACHYTHERAPY, 2011, 10 (06) : 461 - 465
  • [43] Monte Carlo Characterization of a New Directional Pd-103 High Dose Rate Source for Brachytherapy Application
    Heredia, A.
    Robinson, A.
    Henderson, D.
    Thomadsen, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3777 - 3777
  • [44] Monte Carlo characterization of an ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty
    Medich, DC
    Tries, MA
    Munro, JJ
    MEDICAL PHYSICS, 2006, 33 (01) : 163 - 172
  • [45] Single dose irradiation response of pig skin: a comparison of brachytherapy using a single, high dose rate iridium-192 stepping source with 200 kV X-rays
    Hamm, PCJ
    Bakker, EJ
    van den Berg, AP
    van den Aardweg, GJMJ
    Visser, AG
    Levendag, PC
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871): : 762 - 770
  • [46] Dosimetric investigation of high dose rate Ir-192 source with Monte Carlo method
    Acun, H.
    Bozkurt, A.
    Kemikler, G.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 241 - 249
  • [47] Dosimetric comparison of Acuros™ BV and AAPM TG-43 formalism for interstitial iridium-192 high-dose-rate brachytherapy
    Roussakis, Yiannis
    Antorkas, Georgios
    Georgiou, Leonidas
    Strouthos, Iosif
    Karagiannis, Efstratios
    Zamboglou, Constantinos
    Ferentinos, Konstantinos
    Zamboglou, Nikolaos
    Anagnostopoulos, Georgios
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2024, 16 (03) : 211 - 218
  • [48] Dosimetric Considerations for Ytterbium-169, Selenium-75, and Iridium-192 Radioisotopes in High-Dose-Rate Endorectal Brachytherapy
    Shoemaker, Tristan
    Te Vuong
    Glickman, Harry
    Kaifi, Samar
    Famulari, Gabriel
    Enger, Shirin A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (04): : 875 - 883
  • [49] High dose-rate brachytherapy of prostate cancer utilising Iridium-192 after-loading technique:: Technical and methodological aspects
    Edgren, M.
    Ekelund, A. M.
    Albertsson, P.
    Lundberg, L. M.
    Ullen, A.
    Levitt, S.
    Nilsson, S.
    Lennernas, B.
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2006, 29 (06) : 1517 - 1524
  • [50] Treatment of non-melanoma superficial skin cancer with custom-made wax moulds using Iridium-192 high-dose-rate brachytherapy source
    Shah, Kamran Ali
    Ahmad, Habib
    Khattak, Muhammad Rauf
    Ahmad, Misbah
    Javed, Nabila
    Shah, Syed Jawad Ali
    Shaheen, Wajeeha
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 53 - 59