Development and Test of 175 GHz Clinotron Tube

被引:3
|
作者
Likhachev, Aleksandr [1 ]
Ponomarenko, Sergey [1 ]
Kishko, Sergey [1 ]
Kovshov, Yurii [1 ]
Zheltov, Volodymyr [1 ]
Khutoryan, Eduard [1 ]
Moseev, Dmitry [2 ]
Stange, Torsten [2 ]
Kuleshov, Alexei [1 ,3 ]
机构
[1] NASU, O Ya Usikov Inst Radiophys & Elect, Kharkiv, Ukraine
[2] Max Plank Inst Plasma Phys, Greifswald, Germany
[3] Kharkov Natl Univ, Kharkiv, Ukraine
关键词
CW Clinotron; electronic frequency tuning; spectral linewidth; THZ;
D O I
10.1109/IVEC51707.2021.9722552
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results of the development and test of a 175GHz CW clinotron with the output power level of 1W have been presented and discussed. The frequency tuning range from 168GHz to 179GHz and the spectral line width of about 1MHz was achieved with the help of PID feedback control realized in the high-voltage power supply. The experimental test showed the applicability of the designed 175GHz clinotron tube to the thermographic alignment of the quasi-optical transmission line of the CTS-diagnostic at the W7-X stellarator.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] THE TEST-TUBE TEST
    SCHERERJUNDT, M
    CONTRACEPTION FERTILITE SEXUALITE, 1990, 18 (05): : 373 - 378
  • [32] A 175 GHz HBV Frequency Quintupler With 60 mW Output Power
    Bryllert, Tomas
    Malko, Aleksandra
    Vukusic, Josip
    Stake, Jan
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2012, 22 (02) : 76 - 78
  • [33] Development of eddy current test for the fatigue behavior in carbon/epoxy tube
    Kim, CW
    Song, SH
    Yoon, KJ
    Lee, JS
    Ann, HK
    Jang, KS
    Um, TG
    ADVANCES IN FRACTURE AND STRENGTH, PTS 1- 4, 2005, 297-300 : 2059 - 2064
  • [34] Development, standardization, and validation of a biofilm efficacy test: The single tube method
    Goeres, Darla M.
    Walker, Diane K.
    Buckingham-Meyer, Kelli
    Lorenz, Lindsey
    Summers, Jennifer
    Fritz, Blaine
    Goveia, Danielle
    Dickerman, Grace
    Schultz, Johanna
    Parker, Albert E.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2019, 165
  • [35] Development of a test bench of 2.45 GHz ECR ion source for RFQ accelerator
    Vala, S.
    Kumar, R.
    Abhangi, M.
    Kumar, R.
    Bandyopadhyay, M.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [36] Cosimulation and Cold Test Verification of a 220-GHz Sheet Beam Traveling-Wave Tube Amplifier
    Shu, Guoxiang
    Pan, Huaxing
    Li, Qi
    Xie, Xinlun
    Ma, Shaocheng
    Tang, Jiawei
    Liu, Siyuan
    Li, Mingze
    Yin, Huabi
    Ruan, Cunjun
    He, Wenlong
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2024, 71 (02) : 1253 - 1260
  • [37] Collective Thomson Scattering Diagnostic for Wendelstein 7-X at 175 GHz
    Moseev, D.
    Laqua, H. P.
    Stange, T.
    Abramovic, I.
    Nielsen, S. K.
    Akaslompolo, S.
    Avramidis, K.
    Braune, H.
    Gantenbein, G.
    Illy, S.
    Jelonnek, J.
    Jin, J.
    Kasparek, W.
    Krier, L.
    Korsholm, S. B.
    Lechte, C.
    Marek, A.
    Marsen, S.
    Nishiura, M.
    Pagonakis, I.
    Salewski, M.
    Rasmussen, J.
    Tancetti, A.
    Thumm, M.
    Wolf, R. C.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05):
  • [38] A TEST TUBE WAS TAKEN
    TUDGE, C
    NEW SCIENTIST, 1989, 121 (1654) : 63 - 64
  • [39] TEST TUBE CHEMISTRY
    PEACOCKE, TAH
    CHEMISTRY IN BRITAIN, 1987, 23 (04) : 325 - 325
  • [40] TEMPEST IN A TEST TUBE
    不详
    PHOTONICS SPECTRA, 1989, 23 (10) : 160 - &