Development of eddy current test for the fatigue behavior in carbon/epoxy tube

被引:0
|
作者
Kim, CW [1 ]
Song, SH
Yoon, KJ
Lee, JS
Ann, HK
Jang, KS
Um, TG
机构
[1] Konkuk Univ, Artif Muscle Res Ctr, Seoul, South Korea
[2] Korea Univ, Dept Mech Engn, Seoul, South Korea
[3] Konkuk Univ, Dept Aerosp Engn, Seoul, South Korea
[4] Saean Engn Corp, Byucksan Digital Valley 2, Seoul, South Korea
来源
关键词
Eddy Current (EC); carbon/epoxy tube; stress distribution; circular defect; Lissajous figure; EC amplitude; MRPC probe; signal to noise ratio; phase angle;
D O I
10.4028/www.scientific.net/KEM.297-300.2059
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The researches using the Eddy Current Test (ECT) were limited for the particle reinforced metal base composites. It had been impossible to inspect the eddy current since the carbon/epoxy tube had the low electric conductivity of resin layer. However, it has been successful for our previous research to inspect the defect using the EC. In the case of loading to carbon/epoxy tube, the researches of relationship between the failure behavior and the variation of EC signals have not been carried out. Therefore, this research focused on the comparison and the evaluation of the EC signals according to the variation of the defect depth using the unloading and the radial-loading carbon/ epoxy tube. We obtained results are as follow. Firstly, reviewing the stress distribution of carbon/ epoxy tube under the radial-loading, it was known that the defect depth did not have strongly influence on the stress distribution. Therefore, it was believed that the stress distribution was not directly related to the signals of the EC. Secondly, the EC signals similar to that of the unloading specimens could be obtained from the radial-loading specimen of 80 % defect depth. Thirdly, regardless of the unloading and the radial-loading specimens, the defect of 80 % and 100 % depths had the similar phase angles and Lissajous figures. Finally, it was guessed that the length of micro- cracks distributed at the whole specimens under the radial-loading was less than 60 % defect depth.
引用
收藏
页码:2059 / 2064
页数:6
相关论文
共 50 条
  • [1] Restoration of fatigue damage in steel tube by eddy current treatment
    Yang, Chuan
    Xu, Wenchen
    Chen, Yu
    Guo, Bin
    Shan, Debin
    INTERNATIONAL JOURNAL OF FATIGUE, 2019, 124 : 422 - 434
  • [2] Eddy current examination of carbon fibres in carbon-epoxy composites and Kevlar
    Grimberg, R.
    Savin, A.
    Steigmann, R.
    Bruma, A.
    INTERNATIONAL JOURNAL OF MATERIALS & PRODUCT TECHNOLOGY, 2006, 27 (3-4): : 221 - 228
  • [3] Eddy current examination of carbon fibres in carbon-epoxy composites and KEVLAR
    Grimberg, R
    Savin, A
    Steigmann, R
    Bruma, A
    8th International Conference of the Slovenian Society for Non-Destructive Testing, Conference Proceedings: APPLICATION OF CONTEMPORARY NON-DESTRUCTIVE TESTING IN ENGINEERING, 2005, : 223 - 228
  • [4] Interlaminar shear fatigue behavior of glass/epoxy and carbon/epoxy composites
    Makeev, Andrew
    COMPOSITES SCIENCE AND TECHNOLOGY, 2013, 80 : 93 - 100
  • [5] Torsion fatigue behavior of unidirectional carbon/epoxy and glass/epoxy composites
    Ogasawara, Toshio
    Onta, Keiji
    Ogihara, Shinji
    Yokozeki, Tomohiro
    Hara, Eiichi
    COMPOSITE STRUCTURES, 2009, 90 (04) : 482 - 489
  • [6] Eddy current holography evaluation of delamination in carbon-epoxy composites
    Grimberg, R
    Prémel, D
    Savin, A
    Le Bihan, Y
    Placko, D
    INSIGHT, 2001, 43 (04) : 260 - 264
  • [7] System Development for Tube Inspection Based On Eddy Current Technique
    Rerkratn, Apinai
    Cheypoca, Thepjit
    Kaewpoonsuk, Anucha
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 6 - 9
  • [8] EDDY CURRENT TUBE TESTING
    RYDEN, J
    INSTRUMENTS & CONTROL SYSTEMS, 1971, 44 (06): : 117 - &
  • [9] Evaluation of fatigue behavior on repaired carbon fiber/epoxy composites
    Botelho, Edson C.
    Rezende, Mirabel C.
    Mayer, Sergio
    Voorwald, Herman
    JOURNAL OF MATERIALS SCIENCE, 2008, 43 (09) : 3166 - 3172
  • [10] Evaluation of fatigue behavior on repaired carbon fiber/epoxy composites
    Edson C. Botelho
    Mirabel C. Rezende
    Sérgio Mayer
    Herman Voorwald
    Journal of Materials Science, 2008, 43 : 3166 - 3172