Development of eddy current test for the fatigue behavior in carbon/epoxy tube

被引:0
|
作者
Kim, CW [1 ]
Song, SH
Yoon, KJ
Lee, JS
Ann, HK
Jang, KS
Um, TG
机构
[1] Konkuk Univ, Artif Muscle Res Ctr, Seoul, South Korea
[2] Korea Univ, Dept Mech Engn, Seoul, South Korea
[3] Konkuk Univ, Dept Aerosp Engn, Seoul, South Korea
[4] Saean Engn Corp, Byucksan Digital Valley 2, Seoul, South Korea
来源
关键词
Eddy Current (EC); carbon/epoxy tube; stress distribution; circular defect; Lissajous figure; EC amplitude; MRPC probe; signal to noise ratio; phase angle;
D O I
10.4028/www.scientific.net/KEM.297-300.2059
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The researches using the Eddy Current Test (ECT) were limited for the particle reinforced metal base composites. It had been impossible to inspect the eddy current since the carbon/epoxy tube had the low electric conductivity of resin layer. However, it has been successful for our previous research to inspect the defect using the EC. In the case of loading to carbon/epoxy tube, the researches of relationship between the failure behavior and the variation of EC signals have not been carried out. Therefore, this research focused on the comparison and the evaluation of the EC signals according to the variation of the defect depth using the unloading and the radial-loading carbon/ epoxy tube. We obtained results are as follow. Firstly, reviewing the stress distribution of carbon/ epoxy tube under the radial-loading, it was known that the defect depth did not have strongly influence on the stress distribution. Therefore, it was believed that the stress distribution was not directly related to the signals of the EC. Secondly, the EC signals similar to that of the unloading specimens could be obtained from the radial-loading specimen of 80 % defect depth. Thirdly, regardless of the unloading and the radial-loading specimens, the defect of 80 % and 100 % depths had the similar phase angles and Lissajous figures. Finally, it was guessed that the length of micro- cracks distributed at the whole specimens under the radial-loading was less than 60 % defect depth.
引用
收藏
页码:2059 / 2064
页数:6
相关论文
共 50 条
  • [31] Eddy Current Signal Comparison for Tube Identification
    Glass, S. W.
    Vojvodic, R.
    41ST ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 34, 2015, 1650 : 1506 - 1511
  • [32] EDDY-CURRENT METHODS FOR EXAMINATION OF CARBON-FIBER REINFORCED EPOXY-RESINS
    OWSTON, CN
    MATERIALS EVALUATION, 1976, 34 (11) : 237 - &
  • [33] EDDY CURRENT SENSOR ARRAY. APPLICATION TO NONDESTRUCTIVE EVALUATION OF CARBON-EPOXY COMPOSITES
    Savin, Adriana
    Steigmann, Rozina
    Iftimie, Nicoleta
    Bruma, Alina
    Rosu, Dorin
    Grimberg, Raimond
    EUROPEAN NDT DAYS IN PRAGUE 2007: NDE FOR SAFETY, PROCEEDINGS, 2007, : 219 - 228
  • [34] EDDY-CURRENT TEST OF STEEL TUBE EMPLOYING ELECTROMAGNET TECHNIQUE FOR DC-MAGNETIZATION
    KIM, YJ
    YI, JY
    LEE, SY
    JOURNAL OF APPLIED PHYSICS, 1986, 60 (09) : 3327 - 3334
  • [36] FLEXURAL FATIGUE BEHAVIOR OF SEA WATER CONDITIONED CARBON/EPOXY NANOCLAY COMPOSITES
    Tareq, Md. Sarower
    Hosur, Mahesh
    Zainuddin, Shaik
    PROCEEDINGS OF ASME 2023 AEROSPACE STRUCTURES, STRUCTURAL DYNAMICS, AND MATERIALS CONFERENCE, SSDM2023, 2023,
  • [38] Effect of fibre waviness on the compressive fatigue behavior of woven carbon/epoxy laminates
    Maragoni, L.
    Modenato, G.
    De Rossi, N.
    Vescovi, L.
    Quaresimin, M.
    COMPOSITES PART B-ENGINEERING, 2020, 199
  • [39] Effects of low-energy impact on the fatigue behavior of carbon/epoxy composites
    Tai, NH
    Yip, MC
    Lin, JL
    COMPOSITES SCIENCE AND TECHNOLOGY, 1998, 58 (01) : 1 - 8
  • [40] Ply Scale Modeling and Fatigue Behavior of Glass/Carbon Epoxy Hybrid Composites
    Kumar, C. Hemanth
    Bongale, Arunkumar
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2024, : 2912 - 2923