Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: A planning study and early clinical data

被引:59
|
作者
Kuijper, Ingrid T. [1 ]
Dahele, Max [1 ]
Senan, Suresh [1 ]
Verbakel, Wilko F. A. R. [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Radiat Oncol, NL-1081 HV Amsterdam, Netherlands
关键词
Stereotactic radiotherapy; Vertebral metastases; Volumetric modulated arc radiotherapy; Intensity-modulated radiotherapy; CORD COMPRESSION; RANDOMIZED-TRIAL; RADIOSURGERY; METASTASES; CANCER; COLUMN;
D O I
10.1016/j.radonc.2009.12.027
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Outcomes for selected patients with spinal metastases may be improved by dose escalation using stereotactic body radiation therapy (SBRT). As target geometry is complex, we compared SBRT plans using volumetric modulated arc radiotherapy (RapidArc (R), RA) and conventional intensity-modulated radiotherapy (IMRT). Materials and methods Materials and methods: RA and IMRT plans to deliver a fraction of 16 Gy to at least 90% of planning target volume (PTV) were compared for PTV coverage, normal organ sparing and estimated delivery times. Group 1 consisted of PTVs to only vertebral body (n = 3), while group 2 had PTVs encompassing the entire vertebra (n = 4). Finally, RA delivery parameters in four patients were assessed. Results: Both techniques delivered 16 Gy to a mean of 95% and 85% of the PTV in groups 1 and 2, respectively. Spinal cord sparing was comparable; mean V(10-partial cord) for RA and IMRT in group 1 was 3.6%, and was 9.4% versus 11.5%, respectively, in group 2. Estimated mean treatment times for RA with 2-3 arcs and IMRT were comparable. Clinical RA beam-on times ranged from 11 to 15.4 min. Conclusions: Both RA and conventional IMRT plans deliver high quality vertebral SBRT, but plan quality was poorer when the PTV consisted of the entire vertebra. (C) 2010 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 94 (2010) 224-228
引用
收藏
页码:224 / 228
页数:5
相关论文
共 50 条
  • [21] Volumetric Modulated Arc Therapy for Spine Radiosurgery: Superior Treatment Planning and Delivery Compared to Static Beam Intensity Modulated Radiotherapy
    Zach, Leor
    Tsvang, Lev
    Alezra, Dror
    Ben Ayun, Maoz
    Harel, Ran
    [J]. BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [22] STEREOTACTIC LUNG RADIOTHERAPY USING VOLUMETRIC MODULATED ARC THERAPY - A COMPARISON WITH CONVENTIONAL METHODS
    Ong, C. L.
    Verbakel, W.
    Senan, S.
    Cuijpers, J.
    Slotman, B.
    Lagerwaard, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S116 - S117
  • [23] Stereotactic ablative radiotherapy utilising volumetric modulated arc therapy
    Harrow, S.
    [J]. LUNG CANCER, 2013, 79 : S62 - S62
  • [24] Volumetric modulated arc therapy is superior to intensity modulated radiotherapy for liver sparing in stereotactic body radiotherapy for hepatocellular carcinoma
    Kundel, Y.
    Korzets, Y.
    Weinstock-Sabbah, M.
    Moor, A.
    Gordon, N.
    Bragilovski, D.
    Stemmer, S.
    Popovtzer, A.
    Brenner, B.
    Fenig, E.
    Allen, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1022 - S1022
  • [25] Proton Therapy, intensity modulated Radiation Therapy or volumetric modulated Arc Radiotherapy for postoperative Radiotherapy after extrapleural Pleuropneumonectomy of Mesothelioma
    Krayenbuehl, J.
    Hartmann, M.
    Riesterer, O.
    Lomax, A. J.
    Kloeck, S.
    Hug, E. B.
    Ciernik, I. F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 5 - 6
  • [26] Hippocampal Sparing Radiotherapy Using Intensity Modulated Radiotherapy and Volumetric Modulated Arc Therapy
    Moon, S.
    Kim, D.
    Chung, W.
    Yoon, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3437 - 3437
  • [27] Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy
    Rossi, Maddalena M. G.
    Peulen, Heike M. U.
    Belderbos, Jose S. A.
    Sonke, Jan-Jakob
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (02): : 835 - 843
  • [28] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    [J]. RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368
  • [29] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy For Liver Carcinoma
    Chiang, B.
    Schnell, E.
    Hibbitts, K.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E750 - E750
  • [30] Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Non-Small-Cell Lung Cancer with Simultaneously Integrated Boost Radiation Therapy :A Planning Comparison Study
    Liu, T.
    Chen, J.
    Zhang, G.
    Sun, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3524 - 3524