Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

被引:13
|
作者
Park, Kyeongjin [1 ]
Kim, Jinhwan [1 ]
Lim, Kyung Taek [1 ]
Kim, Junhyeok [1 ]
Chang, Hojong [2 ]
Kim, Hyunduk [3 ]
Sharma, Manish [4 ]
Cho, Gyuseong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, 291 Daehak Ro, Daejeon 34141, South Korea
[2] Korea Adv Inst Sci & Technol, Inst Informat Technol Convergence, 291 Daehak Ro, Daejeon 34141, South Korea
[3] Iris Co Ltd, 193 Munji Ro, Daejeon 34051, South Korea
[4] Khalifa Univ, Dept Nucl Engn, Abu Dhabi 127788, U Arab Emirates
关键词
Electronic personal dosimeter; Ambient dose equivalent; G(E) function; PIN diode; CsI(Tl) scintillator; SILICON PHOTOMULTIPLIER; H-ASTERISK(10); NAI(TL);
D O I
10.1016/j.net.2019.06.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H*(10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 x 3 mm(2) PIN diode coupled to a 3 x 3 x 3 mm(3) CsI (TI) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H*(10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H*(10) from the gamma spectra was Am-241, Cs-137, (22) Na, Mn-54, Co-60 verified by using and Co radioisotopes. Furthermore, gamma spectra and H*(10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H*(10) based on the G(E) function for the gamma spectra was then compared with H*(10) calculated by simulation. The relative difference of H*(10) from various single-source spectra was in the range of +/- 2.89%, and the relative difference of H*(10) for a multiple isotope case was in the range of +/- 5.56%. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1991 / 1997
页数:7
相关论文
共 50 条
  • [1] Measurement of ambient dose equivalent using a NaI(Tl) scintillation detector
    Yi, CY
    Jun, JS
    Chai, HS
    Oh, JJ
    Yun, JY
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 74 (04) : 273 - 278
  • [2] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER
    WALSH, ML
    JOHNS, HE
    [J]. HEALTH PHYSICS, 1984, 46 (01): : 55 - 64
  • [3] THERMOLUMINESCENCE DOSIMETER FOR PERSONAL DOSE-EQUIVALENT ASSESSMENT
    DASILVA, TA
    DAROSA, LAR
    CAMPOS, LL
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 58 (01) : 17 - 21
  • [4] Neutron conversion coefficients of ambient dose equivalent and personal dose equivalent
    Al Kanti, Hassan
    El Hajjaji, Otman
    El Bardouni, Tarek
    Mohammed, Maged
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (01): : 52 - 59
  • [5] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER - REPLY
    WALSH, ML
    [J]. HEALTH PHYSICS, 1985, 49 (02): : 316 - 317
  • [6] MEASUREMENT OF PERSONAL DOSE EQUIVALENT OF X AND GAMMA RADIATION BY RING DOSIMETER: RESULTS OF INTERCOMPARISON MEASUREMENTS
    Adamowicz, Malgorzata
    Papierz, Sylwia
    Kacprzyk, Janusz
    Kaminski, Zbigniew
    Zmyslony, Marek
    [J]. MEDYCYNA PRACY, 2013, 64 (05) : 631 - 637
  • [7] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER - COMMENT
    SUTHERLAND, JK
    [J]. HEALTH PHYSICS, 1985, 49 (02): : 315 - 316
  • [8] Personal dose equivalent for photons and its variation with dosimeter position
    Zankl, M
    [J]. HEALTH PHYSICS, 1999, 76 (02): : 162 - 170
  • [9] INVESTIGATION OF A NEW TL INDIVIDUAL DOSIMETER FOR MEASURING PERSONAL DOSE-EQUIVALENT H(P)(D) ON DIFFERENT PHANTOMS
    HUA, J
    DUFTSCHMID, KE
    STRACHOTINSKY, C
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 51 (03) : 201 - 205
  • [10] TL measurement of ambient dose at a Nuclear Medicine Department
    Avila, O.
    Torres-Ulloa, C. L.
    Medina, L. A.
    Trujillo-Zamudio, F. E.
    Gamboa-deBuen, I.
    Buenfil, A. E.
    Brandan, M. E.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1843 - 1846