Real-time quantitative fluorescence measurement of microscale cell culture analog systems

被引:0
|
作者
Oh, Taek-Il [1 ]
Kim, Donghyun [1 ]
Tatosian, Daniel [2 ]
Sung, Jong Hwan [2 ]
Shuler, Michael [2 ]
机构
[1] Yonsei Univ, Sch Elect & Elect Engn, Seoul 120749, South Korea
[2] Cornell Univ, Sch Chem & Biomol Engn, Ithaca, NY 14853 USA
基金
美国国家科学基金会;
关键词
microscale cell culture analog; real time imaging; high-throughput screening; quantitative imaging;
D O I
10.1117/12.700610
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A microscale cell culture analog (mu CCA) is a cell-based lab-on-a-chip assay that, as an animal surrogate, is applied to pharmacological studies for toxicology tests. A mu CCA typically comprises multiple chambers and microfluidics that connect the chambers, which represent animal organs and blood flow to mimic animal metabolism more realistically. A mu CCA is expected to provide a tool for high-throughput drug discovery. Previously, a portable fluorescence detection system was investigated for a single mu CCA device in real-time. In this study, we present a fluorescence-based imaging system that provides quantitative real-time data of the metabolic interactions in mu CCAs with an emphasis on measuring multiple mu CCA samples simultaneously for high-throughput screening. The detection system is based on discrete optics components, with a high-power LED and a charge-coupled device (CCD) camera as a light source and a detector, for monitoring cellular status on the chambers of each mu CCA sample. Multiple samples are characterized mechanically on a motorized linear stage, which is fully-automated. Each mu CCA sample has four chambers, where cell lines MES-SA/DX5, and MES-SA (tumor cells of human uterus) have been cultured. All cell-lines have been transfected to express the fusion protein H2B-GFP, which is a human histone protein fused at the amino terminus to EGFP. As a model cytotoxic drug, 10 mu M doxorubicin (DOX) was used. Real-time quantitative data of the intensity loss of enhanced green fluorescent protein (EGFP) during cell death of target cells have been collected over several minutes to 40 hours. Design issues and improvements are also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Real-time measurement of combustion generated particles with photofragmentation-fluorescence
    Damm, CJ
    Lucas, D
    Sawyer, RF
    Koshland, CP
    APPLIED SPECTROSCOPY, 2001, 55 (11) : 1478 - 1482
  • [32] Real-time Measurement Of Cell Concentration During Bioprinting
    Matavosian, A. A.
    Matthews, J.
    Bonassar, L. J.
    TISSUE ENGINEERING PART A, 2022, 28 : 130 - 131
  • [33] Part 7: Analog-to-digital conversion in real-time systems
    Fowler, K
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2003, 6 (03) : 58 - 64
  • [34] Automated real-time measurement of chemotactic cell motility
    Hadjout, N
    Laevsky, G
    Knecht, DA
    Lynes, MA
    BIOTECHNIQUES, 2001, 31 (05) : 1130 - 1138
  • [35] Periodontal pathogens: A quantitative comparison of anaerobic culture and real-time PCR
    Boutaga, K
    van Winkelhoff, AJ
    Vandenbroucke-Grauls, CMJE
    Savelkoul, PHM
    FEMS IMMUNOLOGY AND MEDICAL MICROBIOLOGY, 2005, 45 (02): : 191 - 199
  • [36] Comparison of Real-Time Quantitative PCR and Culture for the Diagnosis of Emerging Rickettsioses
    Angelakis, Emmanouil
    Richet, Herve
    Rolain, Jean-Marc
    La Scola, Bernard
    Raoult, Didier
    PLOS NEGLECTED TROPICAL DISEASES, 2012, 6 (03)
  • [37] Quantitative analysis of hardware support for real-time operating systems
    Carnegie Mellon Univ, Pittsburgh, United States
    Real Time Syst, 2 (123-142):
  • [38] Quantitative analysis of hardware support for real-time operating systems
    Chatterjee, S
    Strosnider, J
    REAL-TIME SYSTEMS, 1996, 10 (02) : 123 - 142
  • [39] Microscale Temperature Measurements Within Specific Exposure Systems for Real-Time Cellular Characterization
    Nefzi, Amani
    Orlacchio, Rosa
    Carr, Lynn
    Lewis, Noelle
    Percherancier, Yann
    Leveque, Philippe
    Arnaud-Cormos, Delia
    2020 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2020,
  • [40] Emissive Guanosine Analog Applicable for Real-Time Live Cell Imaging
    Steinbuch, Kfir B.
    Cong, Deyuan
    Rodriguez, Anthony J.
    Tor, Yitzhak
    ACS CHEMICAL BIOLOGY, 2024, 19 (08) : 1836 - 1841