Real-time quantitative fluorescence measurement of microscale cell culture analog systems

被引:0
|
作者
Oh, Taek-Il [1 ]
Kim, Donghyun [1 ]
Tatosian, Daniel [2 ]
Sung, Jong Hwan [2 ]
Shuler, Michael [2 ]
机构
[1] Yonsei Univ, Sch Elect & Elect Engn, Seoul 120749, South Korea
[2] Cornell Univ, Sch Chem & Biomol Engn, Ithaca, NY 14853 USA
基金
美国国家科学基金会;
关键词
microscale cell culture analog; real time imaging; high-throughput screening; quantitative imaging;
D O I
10.1117/12.700610
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A microscale cell culture analog (mu CCA) is a cell-based lab-on-a-chip assay that, as an animal surrogate, is applied to pharmacological studies for toxicology tests. A mu CCA typically comprises multiple chambers and microfluidics that connect the chambers, which represent animal organs and blood flow to mimic animal metabolism more realistically. A mu CCA is expected to provide a tool for high-throughput drug discovery. Previously, a portable fluorescence detection system was investigated for a single mu CCA device in real-time. In this study, we present a fluorescence-based imaging system that provides quantitative real-time data of the metabolic interactions in mu CCAs with an emphasis on measuring multiple mu CCA samples simultaneously for high-throughput screening. The detection system is based on discrete optics components, with a high-power LED and a charge-coupled device (CCD) camera as a light source and a detector, for monitoring cellular status on the chambers of each mu CCA sample. Multiple samples are characterized mechanically on a motorized linear stage, which is fully-automated. Each mu CCA sample has four chambers, where cell lines MES-SA/DX5, and MES-SA (tumor cells of human uterus) have been cultured. All cell-lines have been transfected to express the fusion protein H2B-GFP, which is a human histone protein fused at the amino terminus to EGFP. As a model cytotoxic drug, 10 mu M doxorubicin (DOX) was used. Real-time quantitative data of the intensity loss of enhanced green fluorescent protein (EGFP) during cell death of target cells have been collected over several minutes to 40 hours. Design issues and improvements are also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Real-time quantitative PCR for retrovirus-like particle quantification in CHO cell culture
    de Wit, C
    Fautz, C
    Xu, Y
    BIOLOGICALS, 2000, 28 (03) : 137 - 148
  • [22] Cellular chromosome DNA interferes with fluorescence quantitative real-time PCR detection of HBV DNA in culture medium
    Pan, Xiao-Ben
    Wei, Lai
    Han, Jin-Chao
    Gao, Yan
    JOURNAL OF MEDICAL VIROLOGY, 2008, 80 (01) : 47 - 52
  • [23] Quantitative cell analysis in situ on a short time scale using a microscale cell culture assay
    Oh, Taek-il
    Sung, Jong Hwan
    Tatosian, Daniel A.
    Shuler, Michael L.
    Kim, Donghyun
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 885 - +
  • [24] Real-time in vivo quantitative fluorescence measurements in rat kidney physiology
    Kolman, P.
    Pica, A.
    Boyde, A.
    Unwin, R. J.
    JOURNAL OF ANATOMY, 2006, 209 (03) : 417 - 417
  • [25] Real-time Mueller matrix measurement for particulate systems
    Mujat, M
    Dogariu, A
    LASER RADAR TECHNOLOGY AND APPLICATIONS V, 2000, 4035 : 390 - 400
  • [26] In situ visualization and real-time tracking of emulsion and miniemulsion polymerization at the microscale via fluorescence imaging
    Liu, Haotian
    Shi, Jie
    Pu, Yuan
    Wang, Jie-Xin
    Wang, Dan
    Chen, Jian-Feng
    CHEMICAL ENGINEERING SCIENCE, 2020, 211 (211)
  • [27] REAL-TIME MEASUREMENT AND ANALYSIS OF HARMONICS IN POWER SYSTEMS
    Demirbas, Sevki
    Bayhan, Sertac
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2009, 24 (03): : 461 - 468
  • [28] Real-Time Quantitative Measurement of Tumor Cell Migration and Invasion Following Synthetic mRNA Transfection
    Park, Taeju
    Large, Neka
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (196):
  • [29] Development of a microscale cell culture analog to probe naphthalene toxicity
    Viravaidya, K
    Sin, A
    Shuler, ML
    BIOTECHNOLOGY PROGRESS, 2004, 20 (01) : 316 - 323
  • [30] Real-Time Checking of Linear Control Systems Using Analog Checksums
    Banerjee, Suvadeep
    Banerjee, Aritra
    Chatterjee, Abhijit
    Abraham, Jacob A.
    PROCEEDINGS OF THE 2013 IEEE 19TH INTERNATIONAL ON-LINE TESTING SYMPOSIUM (IOLTS), 2013, : 122 - 127