A Novel Tandem of Thermal Desorption Carbon Analyzer and Off-Axis Integrated Cavity Output Spectroscopy for Aerosol Stable Carbon Isotope Ratio Measurement

被引:5
|
作者
Kaul, Daya S. [1 ]
Ning, Zhi [1 ,2 ]
Westerdahl, Dane [2 ]
Yin, Xijie [3 ]
Cary, Robert A. [4 ]
机构
[1] City Univ Hong Kong, Sch Energy & Environm, Hong Kong, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Guy Carpenter Asia Pacific Climate Impact Ctr, Hong Kong, Hong Kong, Peoples R China
[3] State Ocean Adm, Inst Oceanog 3, Lab Ocean & Coast Geol, Xiamen, Peoples R China
[4] Sunset Lab Inc, Tigard, OR USA
关键词
OC-EC; OA-ICOS; Keeling curve; Stable isotopic ratio; Organic aerosol; POSITIVE MATRIX FACTORIZATION; SOLUBLE ORGANIC-CARBON; SOURCE APPORTIONMENT; SEASONAL-VARIATIONS; ELEMENTAL CARBON; BROWN CLOUDS; BIOMASS; SITE; RADIOCARBON; PARTICULATE;
D O I
10.4209/aaqr.2015.05.0288
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel approach for measurement of stable carbon isotopic ratio of atmospheric aerosols was developed by tandem operation of two instruments: a Sunset Organic Carbon-Elemental Carbon (OC-EC) analyzer and an online Carbon Dioxide Stable Isotope Analyzer (LGR, CCIA-36d). Sensitivity, accuracy and measurement uncertainty of the CCIA was comprehensively investigated using the standard reference CO2 gas with known concentration and isotopic ratio. Drift in CCIA measurement due to varying CO2 and water vapor concentration was evaluated and a humidity stabilizer was designed and developed to control the water vapor concentration of exhaust gas flow from OC-EC prior to entering the CCIA. A Keeling approach was applied to separate the ratio in the samples from the mixture of PM sample-produced CO2 and reference gas and we developed a protocol to derive the isotopic composition of the particle samples. A lithium carbonate standard (in powder form) from National Institute of Standards and Technology (NIST) was used to validate measurement of delta C-13 ratios by CCIA. Offline measurement on ambient aerosol and diesel exhaust aerosols produced comparable results of isotopic ratio with literature values. This study demonstrates the utility of this tandem operation for carbon isotopic measurement of atmospheric particles with better than 1.0% precision as a cost-effective alternative of conventional Isotopic Ratio Mass Spectrometer (IR-MS).
引用
收藏
页码:1345 / 1355
页数:11
相关论文
共 50 条
  • [1] Research of Carbon Monoxide Concentration Measurement in Combustion Field by Off-Axis Integrated Cavity Output Spectroscopy
    Lou Deng-cheng
    Rao Wei
    Song Jun-ling
    Wang Kai
    Jiang Ya-jing
    Guo Jian-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3678 - 3684
  • [2] In Situ Measurement of Dissolved Methane and Carbon Dioxide in Freshwater Ecosystems by Off-Axis Integrated Cavity Output Spectroscopy
    Gonzalez-Valencia, Rodrigo
    Magana-Rodriguez, Felipe
    Gerardo-Nieto, Oscar
    Sepulveda-Jauregui, Armando
    Martinez-Cruz, Karla
    Anthony, Katey Walter
    Baer, Doug
    Thalasso, Frederic
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (19) : 11421 - 11428
  • [3] Measurement of Carbon Isotopes in Methane Based on Off-Axis Integrated Cavity Output Spectroscopy Technology with Booster Optical Amplifier
    Yu Runqing
    Xia Hua
    Sun Pengshuai
    Pang Tao
    Wu Bian
    Zhang Zhirong
    ACTA OPTICA SINICA, 2024, 44 (05)
  • [4] Precise Measurement of the Hydrogen Isotope Composition of Phyllosilicates by Continuous Flow Off-Axis Integrated Cavity Output Spectroscopy
    Mering, John A.
    Barker, Shaun L. L.
    ANALYTICAL CHEMISTRY, 2018, 90 (04) : 2852 - 2859
  • [5] Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy
    Dyroff, Christoph
    OPTICS LETTERS, 2011, 36 (07) : 1110 - 1112
  • [6] Intensity enhancement in off-axis integrated cavity output spectroscopy
    Nadeem, Faisal
    Mandon, Julien
    Cristescu, Simona M.
    Harren, Frans J. M.
    APPLIED OPTICS, 2018, 57 (29) : 8536 - 8542
  • [7] Off-axis integrated cavity output spectroscopy and its application
    Tan, Zhongqi
    Long, Xingwu
    OPTICS COMMUNICATIONS, 2010, 283 (07) : 1406 - 1409
  • [8] Sensitivity enhancement in off-axis integrated cavity output spectroscopy
    Centeno, R.
    Mandon, J.
    Cristescu, S. M.
    Harren, F. J. M.
    OPTICS EXPRESS, 2014, 22 (23): : 27985 - 27991
  • [9] Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry
    Melanson, Edward L.
    Swibas, Tracy
    Kohrt, Wendy M.
    Catenacci, Vicki A.
    Creasy, Seth A.
    Plasqui, Guy
    Wouters, Loek
    Speakman, John R.
    Berman, Elena S. F.
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2018, 314 (02): : E124 - E130
  • [10] Recent advances and applications of off-axis integrated cavity output spectroscopy
    Shao, Ligang
    Mei, Jiaoxu
    Chen, Jiajin
    Tan, Tu
    Wang, Guishi
    Liu, Kun
    Gao, Xiaoming
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1489 - 1505