Intensity enhancement in off-axis integrated cavity output spectroscopy

被引:14
|
作者
Nadeem, Faisal [1 ]
Mandon, Julien [1 ]
Cristescu, Simona M. [1 ]
Harren, Frans J. M. [1 ]
机构
[1] Radboud Univ Nijmegen, Inst Mol & Mat, Mol & Laser Phys, Trace Gas Res Grp, Nijmegen, Netherlands
关键词
RING-DOWN SPECTROSCOPY; BREATH ANALYSIS; ABSORPTION; LASER; SPECTROMETER; PATHS; CELLS;
D O I
10.1364/AO.57.008536
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the field of laser-based absorption spectroscopy, off-axis integrated cavity output spectroscopy is considered to be a sensitive and robust method, employing a simple optical design. However, one of the major drawbacks of non-mode-matched cavities combined with highly reflective mirrors (>99.98%) is its low output intensity. Here, we systematically investigate the increase in cavity output intensity, using a third re-injection mirror before the absorption cavity. The presented design not only enables high transmission power but also retains a long effective path length. To investigate the intensity enhancement, we used a CO(2 )absorption line in the near-IR wavelength region at 6240.10 cm(-1). In agreement with our simulation model, we achieved an intensity enhancement factor of 38. We achieved a noise equivalent absorption sensitivity to 1.6 x 10(-8) cm(-1) Hz(-1/2), which is no longer limited by the detectivity of the detector. (C) 2018 Optical Society of America
引用
收藏
页码:8536 / 8542
页数:7
相关论文
共 50 条
  • [1] Sensitivity enhancement in off-axis integrated cavity output spectroscopy
    Centeno, R.
    Mandon, J.
    Cristescu, S. M.
    Harren, F. J. M.
    [J]. OPTICS EXPRESS, 2014, 22 (23): : 27985 - 27991
  • [2] Off-axis integrated cavity output spectroscopy and its application
    Tan, Zhongqi
    Long, Xingwu
    [J]. OPTICS COMMUNICATIONS, 2010, 283 (07) : 1406 - 1409
  • [3] Recent advances and applications of off-axis integrated cavity output spectroscopy
    Shao, Ligang
    Mei, Jiaoxu
    Chen, Jiajin
    Tan, Tu
    Wang, Guishi
    Liu, Kun
    Gao, Xiaoming
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1489 - 1505
  • [4] Wavelength modulated off-axis integrated cavity output spectroscopy in the near infrared
    W. Zhao
    X. Gao
    W. Chen
    W. Zhang
    T. Huang
    T. Wu
    H. Cha
    [J]. Applied Physics B, 2007, 86 : 353 - 359
  • [5] Wavelength modulated off-axis integrated cavity output spectroscopy in the near infrared
    Zhao, W.
    Gao, X.
    Chen, W.
    Zhang, W.
    Huang, T.
    Wu, T.
    Cha, H.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 86 (02): : 353 - 359
  • [6] Denoising Technique in Gas Sensing Based on Off-Axis Integrated Cavity Output Spectroscopy
    Zhang Haipeng
    Zheng Kaiyuan
    Li Junhao
    Liu Zidi
    Li Xiuying
    Zheng Chuantao
    Wang Yiding
    [J]. ACTA OPTICA SINICA, 2021, 41 (24)
  • [7] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    Moyer, E. J.
    Sayres, D. S.
    Engel, G. S.
    St. Clair, Jason M.
    Keutsch, F. N.
    Allen, N. T.
    Kroll, J. H.
    Anderson, J. G.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (03): : 467 - 474
  • [8] OPO Based Off-Axis Integrated Cavity Output Spectroscopy for Rapid Chemical Sensing
    Arslanov, D. D.
    Harren, F. J. M.
    Lindsay, I. D.
    Boller, K. J.
    [J]. 2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [9] Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy
    Dyroff, Christoph
    [J]. OPTICS LETTERS, 2011, 36 (07) : 1110 - 1112
  • [10] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    E.J. Moyer
    D.S. Sayres
    G.S. Engel
    J.M. St. Clair
    F.N. Keutsch
    N.T. Allen
    J.H. Kroll
    J.G. Anderson
    [J]. Applied Physics B, 2008, 92