A Novel Tandem of Thermal Desorption Carbon Analyzer and Off-Axis Integrated Cavity Output Spectroscopy for Aerosol Stable Carbon Isotope Ratio Measurement

被引:5
|
作者
Kaul, Daya S. [1 ]
Ning, Zhi [1 ,2 ]
Westerdahl, Dane [2 ]
Yin, Xijie [3 ]
Cary, Robert A. [4 ]
机构
[1] City Univ Hong Kong, Sch Energy & Environm, Hong Kong, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Guy Carpenter Asia Pacific Climate Impact Ctr, Hong Kong, Hong Kong, Peoples R China
[3] State Ocean Adm, Inst Oceanog 3, Lab Ocean & Coast Geol, Xiamen, Peoples R China
[4] Sunset Lab Inc, Tigard, OR USA
关键词
OC-EC; OA-ICOS; Keeling curve; Stable isotopic ratio; Organic aerosol; POSITIVE MATRIX FACTORIZATION; SOLUBLE ORGANIC-CARBON; SOURCE APPORTIONMENT; SEASONAL-VARIATIONS; ELEMENTAL CARBON; BROWN CLOUDS; BIOMASS; SITE; RADIOCARBON; PARTICULATE;
D O I
10.4209/aaqr.2015.05.0288
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel approach for measurement of stable carbon isotopic ratio of atmospheric aerosols was developed by tandem operation of two instruments: a Sunset Organic Carbon-Elemental Carbon (OC-EC) analyzer and an online Carbon Dioxide Stable Isotope Analyzer (LGR, CCIA-36d). Sensitivity, accuracy and measurement uncertainty of the CCIA was comprehensively investigated using the standard reference CO2 gas with known concentration and isotopic ratio. Drift in CCIA measurement due to varying CO2 and water vapor concentration was evaluated and a humidity stabilizer was designed and developed to control the water vapor concentration of exhaust gas flow from OC-EC prior to entering the CCIA. A Keeling approach was applied to separate the ratio in the samples from the mixture of PM sample-produced CO2 and reference gas and we developed a protocol to derive the isotopic composition of the particle samples. A lithium carbonate standard (in powder form) from National Institute of Standards and Technology (NIST) was used to validate measurement of delta C-13 ratios by CCIA. Offline measurement on ambient aerosol and diesel exhaust aerosols produced comparable results of isotopic ratio with literature values. This study demonstrates the utility of this tandem operation for carbon isotopic measurement of atmospheric particles with better than 1.0% precision as a cost-effective alternative of conventional Isotopic Ratio Mass Spectrometer (IR-MS).
引用
收藏
页码:1345 / 1355
页数:11
相关论文
共 50 条
  • [41] High-sensitive off-axis integrated cavity output spectroscopy and its measurement of ambient CO2 at 2 μm
    Li Zhi-Bin
    Ma Hong-Liang
    Cao Zhen-Song
    Sun Ming-Guo
    Huang Yin-Bo
    Zhu Wen-Yue
    Liu Qiang
    ACTA PHYSICA SINICA, 2016, 65 (05)
  • [42] Off-axis Integrated Cavity-enhanced Infrared Laser Carbon Dioxide Sensor System
    Liu Zi-di
    Zheng Kai-yuan
    Zhang Hai-peng
    Zheng Chuan-tao
    Wang Yi-ding
    ACTA PHOTONICA SINICA, 2020, 49 (11)
  • [43] Measurement of Low-Concentration Water Vapor Based on Off-Axis Integrated Cavity Absorption Spectroscopy
    Yang Huinan
    Chen Ning
    Chen Jun
    ACTA OPTICA SINICA, 2018, 38 (02)
  • [44] Sensitive absorption measurements in the near-infrared region using off-axis integrated cavity output spectroscopy
    Baer, DS
    Paul, JB
    Gupta, M
    O'Keefe, A
    DIODE LASERS AND APPLICATIONS IN ATMOSPHERIC SENSING, 2002, 4817 : 167 - 176
  • [45] Off-axis integrated-cavity-output spectroscopy for trace-gas concentration measurements: modeling and performance
    Maddaloni, Pasquale
    Gagliardi, Gianluca
    Malara, Pietro
    De Natale, Paolo
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2006, 23 (09) : 1938 - 1945
  • [46] Observation and Analysis of Taizhou Atmosphere NH3 Concentration by Off-Axis Integrated Cavity Output Spectroscopy
    Zhang Guo-xian
    Hu Ren-zhi
    Xie Pin-hua
    Wang Feng-yang
    Wang Yi-hui
    Tong Jin-zhao
    Chen Shi-yi
    Li Shu-le
    Qiu Wan-yi
    Liu Wen-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (02) : 360 - 367
  • [47] Measurement of the stable carbon isotope ratio of atmospheric volatile organic compounds using chromatography, combustion, and isotope ratio mass spectrometry coupled with thermal desorption
    Kawashima, Hiroto
    Murakami, Mai
    ATMOSPHERIC ENVIRONMENT, 2014, 89 : 140 - 147
  • [48] Simultaneous detection of hydrogen sulfide and carbon dioxide based on off-axis integrated cavity output spectroscopy using a near-infrared distributed feedback diode laser
    Tian, Xing
    Cheng, Gang
    Cao, Yanan
    Chen, Jiajin
    Liu, Kun
    Gao, Xiaoming
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2021, 63 (08) : 2074 - 2078
  • [49] Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy
    Baer, DS
    Paul, JB
    Gupta, JB
    O'Keefe, A
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 261 - 265
  • [50] Design and experiment of re-injection off-axis integrated cavity output spectroscopy technology in 2 μm band
    Zhou Zi-Xin
    Huang Yin-Bo
    Lu Xing-Ji
    Yuan Zi-Hao
    Cao Zhen-Song
    ACTA PHYSICA SINICA, 2019, 68 (12)