Small-diameter vascular graft using co-electrospun composite PCL/PU nanofibers

被引:51
|
作者
Jirofti, Nafiseh [1 ]
Mohebbi-Kalhori, Davod [1 ,2 ]
Samimi, Abdolreza [1 ]
Hadjizadeh, Afra [3 ]
Kazemzadeh, Gholam Hossein [4 ]
机构
[1] Univ Sistan & Baluchestan, Chem Engn Dept, Zahedan, Iran
[2] Univ Sistan & Baluchestan, Cent Lab, Zahedan, Iran
[3] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
[4] Mashhad Univ Med Sci, Imam Reza Hosp, Vasc & Endovasc Surg Res Ctr, Dept Vasc Surg, Mashhad, Iran
关键词
Vero cell; small-caliber vascular graft; rat and sheep models; composite PCL/PU scaffold; TISSUE ENGINEERING APPLICATIONS; MECHANICAL-PROPERTIES; POLYMER NANOFIBERS; SCAFFOLDS; FIBERS; COLLAGEN; POLYCAPROLACTONE; BIOMATERIALS; REGENERATION; FABRICATION;
D O I
10.1088/1748-605X/aad4b5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Small-diameter vascular scaffolds have been developed by a co-electrospinning method using polyethylene terephthalate (PCL) and elastic polytetrafluoroethylene (PU) as biopolymers with long degradation time. Although they possess favorable properties, individually these two polymers do not meet the requirements for the production of synthetic vascular scaffolds. The co-electrospinning method was adopted to develop and mechanically improve the composite PCL/PU vascular scaffolds. The morphological, mechanical and biological properties of these vascular scaffolds were evaluated through scanning electron microscopy, differential scanning calorimetry, Fourier transform infrared spectroscopy, compliance, tensile testing and MTT assay. The in vivo study of the vascular scaffolds was performed by implanting them on rat and sheep models. The compliance of the composite vascular scaffolds improved by up to 43% through an increased percentage of PU from 10%-90%. The obtained UTS of the scaffolds at 10%, 25%, 50%, 75% and 90% of PU were 4.7 +/- 0.34, 3.4 +/- 0.6, 4.8 +/- 0.62, 2.2 +/- 0.34 and 4.4 +/- 1.9 MPa, respectively. The results of MTT assays indicated that the cell growth on the scaffolds was augmented when compared to the control, from day one to day seven. Mild edema, mild foreign-body granulomatous reaction and mild fibrosis were observed by pathology test as the side effects in the composite scaffold with 50% PCL. Doppler ultrasound and angiography images confirm that no aneurysm, thrombogenesis, neointimal hyperplasia or occlusion exist, and there is complete patency at the end of an eight month investigation. The fabricated composite vascular scaffolds provide appropriate mechanical and biological properties and clinical requirements, indicating their required potential to be applied as a small-diameter vascular graft.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Co-electrospun blends of PU and PEG as potential biocompatible scaffolds for small-diameter vascular tissue engineering
    Wang, Heyun
    Feng, Yakai
    Fang, Zichen
    Yuan, Wenjie
    Khan, Musammir
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (08): : 2306 - 2315
  • [2] Small-diameter tissue engineered vascular graft made of electrospun PCL/lecithin blend
    Min Zhang
    Kai Wang
    Zhexiang Wang
    Bin Xing
    Qiang Zhao
    Deling Kong
    [J]. Journal of Materials Science: Materials in Medicine, 2012, 23 : 2639 - 2648
  • [3] Small-diameter tissue engineered vascular graft made of electrospun PCL/lecithin blend
    Zhang, Min
    Wang, Kai
    Wang, Zhexiang
    Xing, Bin
    Zhao, Qiang
    Kong, Deling
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (11) : 2639 - 2648
  • [4] Tailored electrospun small-diameter graft for vascular prosthesis
    Ferrari, Pier Francesco
    Aliakbarian, Bahar
    Lagazzo, Alberto
    Tamayol, Ali
    Palombo, Domenico
    Perego, Patrizia
    [J]. INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2017, 66 (12) : 635 - 643
  • [5] Small-diameter decellularized vascular graft with electrospun polycaprolactone
    Cuenca, John Patrick
    Padalhin, Andrew
    Lee, Byong-Taek
    [J]. MATERIALS LETTERS, 2021, 284
  • [6] A Small-diameter Decellularized Vascular Graft Covered with Electrospun Fibers
    Kimura, T.
    Morita, H.
    Wu, P.
    Nakamura, N.
    Nam, K.
    Fujisato, T.
    Kishida, A.
    [J]. TISSUE ENGINEERING PART A, 2015, 21 : S239 - S239
  • [7] Fabrication and characterization of a novel compliant small-diameter PET/PU/PCL triad-hybrid vascular graft
    Jirofti, Nafiseh
    Mohebbi-Kalhori, Davod
    Samimi, Abdolreza
    Hadjizadeh, Afra
    Kazemzadeh, Gholam Hossein
    [J]. BIOMEDICAL MATERIALS, 2020, 15 (05)
  • [8] Small-diameter PCL/PU vascular graft modified with heparin-aspirin compound for preventing the occurrence of acute thrombosis
    Zhou, Si-Yuan
    Li, Lei
    Xie, Enzehua
    Li, Mei-Xi
    Cao, Jian-Hua
    Yang, Xiu-Bin
    Wu, Da-Yong
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2023, 249
  • [9] An electrospun strong PCL/PU composite vascular graft with mechanical anisotropy and cyclic stability
    Guo, Fengyun
    Wang, Nu
    Wang, Li
    Hou, Lanlan
    Ma, Lan
    Liu, Jing
    Chen, Yuee
    Fan, Bingbing
    Zhao, Yong
    [J]. JOURNAL OF MATERIALS CHEMISTRY A, 2015, 3 (09) : 4782 - 4787
  • [10] Mechanical responses of a compliant electrospun poly(L-lactide-co-ε-caprolactone) small-diameter vascular graft
    Inoguchi, H
    Kwon, IK
    Inoue, E
    Takamizawa, K
    Maehara, Y
    Matsuda, T
    [J]. BIOMATERIALS, 2006, 27 (08) : 1470 - 1478