Fabrication and characterization of a novel compliant small-diameter PET/PU/PCL triad-hybrid vascular graft

被引:23
|
作者
Jirofti, Nafiseh [1 ]
Mohebbi-Kalhori, Davod [1 ,2 ]
Samimi, Abdolreza [1 ]
Hadjizadeh, Afra [3 ]
Kazemzadeh, Gholam Hossein [4 ]
机构
[1] Univ Sistan & Baluchestan, Dept Chem Engn, Zahedan, Iran
[2] Univ Sistan & Baluchestan, Cent Lab, Zahedean, Iran
[3] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
[4] Mashhad Univ Med Sci, Imam Reza Hosp, Dept Vasc Surg Vasc & Endovasc Surg, Surg Res Ctr, Mashhad, Razavi Khorasan, Iran
关键词
electrospinning; hybrid structure; compliance; pathology; MTT assay; Mullins effect; BIODEGRADABLE POLYMERS; SCAFFOLDS; POLYCAPROLACTONE; NANOFIBERS; POROSITY; RELEASE; MATRIX;
D O I
10.1088/1748-605X/ab8743
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nanomaterial structures are highly contributive in tissue engineering vascular scaffolds (TEVS) due to their ability to mimic the nanoscale dimension of the natural extracellular matrix (ECM) and the existing mechanical match between the native blood vessel and the scaffold as a vascular graft. The aim of this study was to develop and mechanically improve the nanofibrous triad-hybrid scaffolds with different composite ratios of polyethylene terephthalate (PET), polyurethane (PU), and polycaprolactone (PCL). The morphological, biological, mechanical, and biomechanical properties of the neat and hybrid structures were examined using scanning electron microscopy (SEM), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), tensile strength, compliance, burst pressure, MTT assay, and by implanting the specimens under rat skin to explore the immune systemin vivo. The results showed that the fiber diameter and porosity changes in the triad-hybrid electrospun scaffold ranged within 388 +/- 88 to 547 +/- 89 nm and 56.60 +/- 2.06% to 75.00 +/- 1.94%, respectively. In addition, the changes in the tensile strength and force in the scaffolds were within the ranges 2.7 +/- 0.44 to 5.27 +/- 0.83 MPa and 2.68 +/- 0.19 to 10.03 +/- 0.75 MPa, respectively. Also, the compliance and burst pressure of the structures were reported as 4.05 +/- 0.21 to 7.09 +/- 0.49 and 1623 +/- 329 to 2560 +/- 121 mmHg, respectively. According to the MTT assay, high cell viability was observed on the triad-hybrid structures with a high percentage of PET when compared to that of PU. The findings of this research demonstrate that the PET/PU/PCL triad-hybrid vascular scaffold has enough potential to be used in vascular tissue engineering application.
引用
收藏
页数:15
相关论文
共 30 条
  • [1] Fabrication and Characterization of Electrospun Bi-Hybrid PU/PET Scaffolds for Small-Diameter Vascular Grafts Applications
    Marziyeh Khodadoust
    Davod Mohebbi-Kalhori
    Nafiseh Jirofti
    [J]. Cardiovascular Engineering and Technology, 2018, 9 : 73 - 83
  • [2] Fabrication and Characterization of Electrospun Bi-Hybrid PU/PET Scaffolds for Small-Diameter Vascular Grafts Applications
    Khodadoust, Marziyeh
    Mohebbi-Kalhori, Davod
    Jirofti, Nafiseh
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (01) : 73 - 83
  • [3] Small-diameter vascular graft using co-electrospun composite PCL/PU nanofibers
    Jirofti, Nafiseh
    Mohebbi-Kalhori, Davod
    Samimi, Abdolreza
    Hadjizadeh, Afra
    Kazemzadeh, Gholam Hossein
    [J]. BIOMEDICAL MATERIALS, 2018, 13 (05)
  • [4] ELASTIC PROPERTIES AND STRENGTH OF A NOVEL SMALL-DIAMETER, COMPLIANT POLYURETHANE VASCULAR GRAFT
    HAYASHI, K
    TAKAMIZAWA, K
    SAITO, T
    KIRA, K
    HIRAMATSU, K
    KONDO, K
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A2): : 229 - 244
  • [5] FABRICATION AND CHARACTERIZATION OF SMALL-DIAMETER VASCULAR PROSTHESES
    KOWLIGI, RR
    VONMALTZAHN, WW
    EBERHART, RC
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1988, 22 (A3): : 245 - 256
  • [6] Small-diameter PCL/PU vascular graft modified with heparin-aspirin compound for preventing the occurrence of acute thrombosis
    Zhou, Si-Yuan
    Li, Lei
    Xie, Enzehua
    Li, Mei-Xi
    Cao, Jian-Hua
    Yang, Xiu-Bin
    Wu, Da-Yong
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2023, 249
  • [7] Fabrication of strong, bioactive vascular grafts with PCL/collagen and PCL/silica bilayers for small-diameter vascular applications
    Park, Suhyung
    Kim, Jinyoung
    Lee, Min-Kyu
    Park, Cheonil
    Jung, Hyun-Do
    Kim, Hyoun-Ee
    Jang, Tae-Sik
    [J]. MATERIALS & DESIGN, 2019, 181
  • [8] Small-diameter tissue engineered vascular graft made of electrospun PCL/lecithin blend
    Min Zhang
    Kai Wang
    Zhexiang Wang
    Bin Xing
    Qiang Zhao
    Deling Kong
    [J]. Journal of Materials Science: Materials in Medicine, 2012, 23 : 2639 - 2648
  • [9] Small-diameter tissue engineered vascular graft made of electrospun PCL/lecithin blend
    Zhang, Min
    Wang, Kai
    Wang, Zhexiang
    Xing, Bin
    Zhao, Qiang
    Kong, Deling
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (11) : 2639 - 2648
  • [10] A novel polyurethane modified with biomacromolecules for small-diameter vascular graft applications
    Shiva Asadpour
    Hamid Yeganeh
    Jafar Ai
    Hossein Ghanbari
    [J]. Journal of Materials Science, 2018, 53 : 9913 - 9927