Small-diameter vascular graft using co-electrospun composite PCL/PU nanofibers

被引:51
|
作者
Jirofti, Nafiseh [1 ]
Mohebbi-Kalhori, Davod [1 ,2 ]
Samimi, Abdolreza [1 ]
Hadjizadeh, Afra [3 ]
Kazemzadeh, Gholam Hossein [4 ]
机构
[1] Univ Sistan & Baluchestan, Chem Engn Dept, Zahedan, Iran
[2] Univ Sistan & Baluchestan, Cent Lab, Zahedan, Iran
[3] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
[4] Mashhad Univ Med Sci, Imam Reza Hosp, Vasc & Endovasc Surg Res Ctr, Dept Vasc Surg, Mashhad, Iran
关键词
Vero cell; small-caliber vascular graft; rat and sheep models; composite PCL/PU scaffold; TISSUE ENGINEERING APPLICATIONS; MECHANICAL-PROPERTIES; POLYMER NANOFIBERS; SCAFFOLDS; FIBERS; COLLAGEN; POLYCAPROLACTONE; BIOMATERIALS; REGENERATION; FABRICATION;
D O I
10.1088/1748-605X/aad4b5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Small-diameter vascular scaffolds have been developed by a co-electrospinning method using polyethylene terephthalate (PCL) and elastic polytetrafluoroethylene (PU) as biopolymers with long degradation time. Although they possess favorable properties, individually these two polymers do not meet the requirements for the production of synthetic vascular scaffolds. The co-electrospinning method was adopted to develop and mechanically improve the composite PCL/PU vascular scaffolds. The morphological, mechanical and biological properties of these vascular scaffolds were evaluated through scanning electron microscopy, differential scanning calorimetry, Fourier transform infrared spectroscopy, compliance, tensile testing and MTT assay. The in vivo study of the vascular scaffolds was performed by implanting them on rat and sheep models. The compliance of the composite vascular scaffolds improved by up to 43% through an increased percentage of PU from 10%-90%. The obtained UTS of the scaffolds at 10%, 25%, 50%, 75% and 90% of PU were 4.7 +/- 0.34, 3.4 +/- 0.6, 4.8 +/- 0.62, 2.2 +/- 0.34 and 4.4 +/- 1.9 MPa, respectively. The results of MTT assays indicated that the cell growth on the scaffolds was augmented when compared to the control, from day one to day seven. Mild edema, mild foreign-body granulomatous reaction and mild fibrosis were observed by pathology test as the side effects in the composite scaffold with 50% PCL. Doppler ultrasound and angiography images confirm that no aneurysm, thrombogenesis, neointimal hyperplasia or occlusion exist, and there is complete patency at the end of an eight month investigation. The fabricated composite vascular scaffolds provide appropriate mechanical and biological properties and clinical requirements, indicating their required potential to be applied as a small-diameter vascular graft.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [11] Electrospun Chitosan( CS)/Poly( L-lactic-co-ε-caprolactone)( PLCL ) Nanofibers and Their Potential as Small-Diameter Vascular Scaffold
    陶玲
    王伟忠
    刘顶华
    杜海波
    张骞骞
    陈良
    何创龙
    Journal of Donghua University(English Edition), 2018, 35 (01) : 32 - 37
  • [12] Development of small-diameter vascular grafts using PCL/PLA/gelatin/ PVA/hyaluronic acid nanofibers containing VEGF/enoxaparin
    Zendedel, Elham
    Javdani, Moosa
    Ebrahimi-Barough, Somayeh
    Ai, Jafar
    Jaafari, Mahmoud Reza
    Mirzaei, Seyed Abbas
    Soleimannejad, Mostafa
    Askari, Vahid Reza
    Asadpour, Shiva
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 101
  • [13] Therapeutic strategies for small-diameter vascular graft calcification
    Teng, Yanjiao
    Xu, Yang
    Lv, Pengfei
    Song, Lin
    Yang, Jianing
    Wang, Xiudan
    Guo, Xiaoqin
    Wang, Shufang
    Hou, Shike
    Lv, Qi
    Shi, Jie
    CHEMICAL ENGINEERING JOURNAL, 2024, 487
  • [14] Develop A Small-diameter Vascular Graft With Amniotic Membrane
    Wang, B.
    TISSUE ENGINEERING PART A, 2023, 29 (9-10)
  • [15] Small-diameter vascular graft prostheses: Current status
    Bos, GW
    Poot, AA
    Beugeling, T
    van Aken, WG
    Feijen, J
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1998, 106 (02) : 100 - 115
  • [16] Future Perspectives in Small-Diameter Vascular Graft Engineering
    Mallis, Panagiotis
    Kostakis, Alkiviadis
    Stavropoulos-Giokas, Catherine
    Michalopoulos, Efstathios
    BIOENGINEERING-BASEL, 2020, 7 (04): : 1 - 40
  • [17] Effect of porosity on small-diameter vascular graft healing
    Contreras, MA
    Quist, WC
    LoGerfo, FW
    MICROSURGERY, 2000, 20 (01) : 15 - 21
  • [18] Fabrication and Characterization of Electrospun Bi-Hybrid PU/PET Scaffolds for Small-Diameter Vascular Grafts Applications
    Marziyeh Khodadoust
    Davod Mohebbi-Kalhori
    Nafiseh Jirofti
    Cardiovascular Engineering and Technology, 2018, 9 : 73 - 83
  • [19] Fabrication and Characterization of Electrospun Bi-Hybrid PU/PET Scaffolds for Small-Diameter Vascular Grafts Applications
    Khodadoust, Marziyeh
    Mohebbi-Kalhori, Davod
    Jirofti, Nafiseh
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (01) : 73 - 83
  • [20] Evaluation of mechanical properties and biocompatibility of three-layer PCL/PLLA small-diameter vascular graft with pore diameter gradient
    Liu, Donglei
    Han, Jiaxin
    Zhuang, Xijing
    Gao, Yang
    Wang, Wenjun
    Qin, Dan
    Dong, Xufeng
    EUROPEAN POLYMER JOURNAL, 2023, 186