Quantification of regurgitation in mitral valve prolapse with four-dimensional flow cardiovascular magnetic resonance

被引:14
|
作者
Spampinato, Ricardo A. [1 ]
Jahnke, Cosima [2 ]
Crelier, Gerard [3 ]
Lindemann, Frank [2 ]
Fahr, Florian [1 ]
Czaja-Ziolkowska, Monika [2 ]
Sieg, Franz [1 ]
Strotdrees, Elfriede [1 ]
Hindricks, Gerhard [2 ]
Borger, Michael A. [1 ]
Paetsch, Ingo [2 ]
机构
[1] Univ Leipzig, Dept Cardiac Surg, Heart Ctr Leipzig, Struempellstr 39, D-04289 Leipzig, Germany
[2] Univ Leipzig, Dept Cardiol & Electrophysiol, Heart Ctr Leipzig, Struempellstr 39, D-04289 Leipzig, Germany
[3] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
Degenerative mitral regurgitation; Mitral valve prolapse; Quantification of mitral valve regurgitation; Four-dimensional; Cardiovascular magnetic resonance; Echocardiography; ECHOCARDIOGRAPHY; SOCIETY; MRI;
D O I
10.1186/s12968-021-00783-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundFour-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE).MethodsSix healthy subjects and 54 patients (5516 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n=12), moderate-severe (n=12), and severe MR (n=30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DF(direct)) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DF(indirect)).ResultsThere was moderate to strong correlation between methods (r=0.59-0.84, p<0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DF(indirect), 17.2 ml [8.4-25.9]; PISA vs. 4DF(direct), 27.9 ml [19.1-36.8]; p<0.001). Only indirect CMR methods (CMR vs. 4DF(indirect)) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 +/- 26 ml [- 50 to 52], p=0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%).Conclusions In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DF(indirect) quantification has higher intra- and inter-technique agreement than 4DF(direct) quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Controversies in quantification of mitral valve regurgitation: role of cardiac magnetic resonance imaging
    Connelly, Kim A.
    Ho, Edwin C.
    Leong-Poi, Howard
    CURRENT OPINION IN CARDIOLOGY, 2017, 32 (02) : 152 - 160
  • [32] Automated Cardiac Valve Tracking for Flow Quantification with Four-dimensional Flow MRI
    Kamphuis, Vivian P.
    Roest, Arno A. W.
    Marsan, Nina Ajmone
    van den Boogaard, Pieter J.
    Kroft, Lucia J. M.
    Aben, Jean-Paul
    Bax, Jeroen J.
    de Roos, Albert
    Lamb, Hildo J.
    Westenberg, Jos J. M.
    RADIOLOGY, 2019, 290 (01) : 70 - 78
  • [33] In vitro four-dimensional flow magnetic resonance analysis of the effect of pericardial valve design on aortic flow
    Tasca G.
    Sturla F.
    Jaworek M.
    Giese D.
    Menicanti L.
    Vismara R.
    Lombardi M.
    Redaelli A.
    Journal of Medical Engineering and Technology, 2022, 46 (03): : 209 - 219
  • [34] Quantification of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: Comparison of techniques
    Kon, MWS
    Myerson, SG
    Moat, NE
    Pennell, DJ
    JOURNAL OF HEART VALVE DISEASE, 2004, 13 (04): : 600 - 607
  • [35] Indirect quantification of mitral regurgitation using cardiovascular magnetic resonance: A comparison of techniques
    Christian L Polte
    Odd Bech-Hanssen
    Åse A Johnsson
    Sinsia A Gao
    Kerstin M Lagerstrand
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [36] In vitro assessment of heart valve bioprostheses by cardiovascular magnetic resonance: four-dimensional mapping of flow patterns and orifice area planimetry
    von Knobelsdorff-Brenkenhoff, Florian
    Dieringer, Matthias A.
    Greiser, Andreas
    Schulz-Menger, Jeanette
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (03) : 736 - 742
  • [37] Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement
    Hirokazu Komoriyama
    Kiwamu Kamiya
    Toshiyuki Nagai
    Noriko Oyama-Manabe
    Satonori Tsuneta
    Yuta Kobayashi
    Yoshiya Kato
    Miwa Sarashina
    Kazunori Omote
    Takao Konishi
    Takuma Sato
    Shingo Tsujinaga
    Hiroyuki Iwano
    Yasushige Shingu
    Satoru Wakasa
    Toshihisa Anzai
    Journal of Cardiovascular Magnetic Resonance, 23
  • [38] Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement
    Komoriyama, Hirokazu
    Kamiya, Kiwamu
    Nagai, Toshiyuki
    Oyama-Manabe, Noriko
    Tsuneta, Satonori
    Kobayashi, Yuta
    Kato, Yoshiya
    Sarashina, Miwa
    Omote, Kazunori
    Konishi, Takao
    Sato, Takuma
    Tsujinaga, Shingo
    Iwano, Hiroyuki
    Shingu, Yasushige
    Wakasa, Satoru
    Anzai, Toshihisa
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [39] Normalization of Transvalvular Flow Patterns After Bicuspid Aortic Valve Repair: Insights From Four-Dimensional Flow Cardiovascular Magnetic Resonance Imaging
    Bannas, Peter
    Lenz, Alexander
    Petersen, Johannes
    Sinn, Martin
    Adam, Gerhard
    Reichenspurner, Hermann
    Girdauskas, Evaldas
    ANNALS OF THORACIC SURGERY, 2018, 106 (06): : E319 - E320
  • [40] Four-dimensional flow cardiovascular magnetic resonance for the evaluation of the atrial baffle after Mustard repair
    van der Palen, Roel L. F.
    Westenberg, Jos J. M.
    Hazekamp, Mark G.
    Kuipers, Irene M.
    Roest, Arno A. W.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (03) : 353 - 353