Two new type passive residual heat removal systems for nuclear reactors

被引:1
|
作者
Ma, CW [1 ]
Zhang, YJ [1 ]
Zhang, YJ [1 ]
Li, J [1 ]
机构
[1] Tsing Hua Univ, Inst Nucl Energy Technol, Beijing 100084, Peoples R China
关键词
passive safety; natural circulation; reactor; residual heat;
D O I
10.3327/jnst.40.114
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The residual heat removal system is an important safety system for nuclear reactors. Passive design of the residual heat removal system attracted more and more attention. Two new type passive residual heat removal systems, which have been used in multipurpose reactors developed in China, are introduced and the main experimental results are presented in this report. A simple comparison between the two systems is also given.
引用
下载
收藏
页码:114 / 118
页数:5
相关论文
共 50 条
  • [21] Study on the Passive Residual Heat Removal System with Heat Pipe in Pool Type Heating Reactor
    Lyv J.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (01): : 79 - 83
  • [22] Transient analysis and optimization of passive residual heat removal heat exchanger in advanced nuclear power plant
    Yan-Bin Liu
    Xiang-Yu Meng
    Xue-Sheng Wang
    Qi-Ming Men
    Yu-Yang Yuan
    Jia-Ming Cao
    Nuclear Science and Techniques, 2022, 33
  • [23] NUCLEAR-PLANT AGING STUDY OF RESIDUAL HEAT REMOVAL SYSTEMS
    LOFARO, R
    GUNTHER, W
    SUBUDHI, M
    TAYLOR, J
    NUCLEAR ENGINEERING AND DESIGN, 1990, 118 (03) : 375 - 380
  • [24] NUMERICAL INVESTIGATION ON HEAT REMOVAL CAPACITY OF PASSIVE RESIDUAL HEAT REMOVAL HEAT EXCHANGER
    Zhang, Wenwen
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 4, 2014,
  • [25] Numerical simulation of passive residual heat removal heat exchanger
    Xue, Ruo-Jun
    Deng, Cheng-Cheng
    Peng, Min-Jun
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (04): : 429 - 435
  • [26] Pilot numerical study of new design of passive residual heat removal heat exchanger tubes
    Wu, Hsingtzu
    Yan, Linfeng
    Yuan, Lanshan
    PROGRESS IN NUCLEAR ENERGY, 2022, 146
  • [27] Operation characteristics analyses on a marine-type passive residual heat removal system
    Wang, Chenyang
    Xia, Genglei
    Cong, Tenglong
    Peng, Minjun
    Lyu, Xing
    Sun, Lin
    ANNALS OF NUCLEAR ENERGY, 2018, 120 : 546 - 558
  • [28] Investigation of passive residual heat removal system for VVERs: Effects of finned type heat exchanger tubes
    Ayhan, Huseyin
    Sokmen, Cemal Niyazi
    APPLIED THERMAL ENGINEERING, 2016, 108 : 466 - 474
  • [29] Analysis of passive residual heat removal system in AP1000 nuclear power plant
    Sierchula, J.
    INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENTAL DEVELOPMENT, 2019, 214
  • [30] Simulation experimental research on passive residual heat removal performance for nuclear seawater desalination reactor
    Nie, Chang-Hua
    Xu, Shi-Jie
    Liu, Xun
    Zhuo, Wen-Bin
    Li, Chang-Lin
    Zheng, Hua
    Li, Peng-Zhou
    Yu, Qing-Lin
    Hedongli Gongcheng/Nuclear Power Engineering, 2013, 34 (06): : 102 - 106