Pilot numerical study of new design of passive residual heat removal heat exchanger tubes

被引:2
|
作者
Wu, Hsingtzu [1 ]
Yan, Linfeng [1 ]
Yuan, Lanshan [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan, Hubei, Peoples R China
关键词
IRWST; PRHR HX tubes; Spiral design; CFD; THERMAL STRATIFICATION; NATURAL-CONVECTION; SECONDARY-SIDE; HYDRAULICS; IRWST;
D O I
10.1016/j.pnucene.2022.104150
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A passive residual heat removal heat exchanger (PRHR HX) is an important component of the passive safety system in an advanced nuclear power plant. In the current design of PRHR HXs with C-shaped tubes, thermal stratification occurs, and it inhibits heat transfer process. Here, we propose replacing these tubes with spiral tubes not only to enhance the heat transfer performance, but also increase cooling capacity. In this pilot study, CFD was used to compute the single-phase natural convection of both designs for comparison and analysis. The computation of a PRHR HX with C-shape tubes is validated with experimental data, and the use of Boussinesq approximation is justified. The computational results of simplified models suggest that with the same inlet and outlet temperatures (difference <0.001%), the new design with a spiral-shape tube not only alleviates the thermal stratification by 10.57% up to 600 s but also improves heat transfer by 75.5 W/m(2).K. In addition, the proposed design has a smaller pressure drop by 7.19%, and the volume of the proposed design is smaller by 22.0%. It suggests that the proposed design not only saves material of tubes, but also results in more water in the water tank to cool the reactor core in emergencies, increasing cooling capacity of a PRHR HX. Finally, sensitivity analysis suggests that the influence of inlet velocity oscillation on both designs was similar regarding the magnitude of pressure drop, the average heat transfer coefficient, and the outlet temperature. The results obtained may be used to inspire new design for PRHR HX tubes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] NUMERICAL INVESTIGATION ON HEAT REMOVAL CAPACITY OF PASSIVE RESIDUAL HEAT REMOVAL HEAT EXCHANGER
    Zhang, Wenwen
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    [J]. PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 4, 2014,
  • [2] The Design and Research on a Passive Containment Residual Heat Removal Exchanger
    Wang, Qianglong
    Chen, Lei
    Qiu, Jinrong
    [J]. 10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 181 - 189
  • [3] Numerical and experimental study of the transient conjugate heat transfer and fluid flow of passive residual heat removal heat exchanger
    Liu, Yanbin
    Mu, Zhaozhang
    Wang, Xuesheng
    Meng, Xiangyu
    Yuan, Yuyang
    Cao, Jiaming
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 181
  • [4] Investigation of passive residual heat removal system for VVERs: Effects of finned type heat exchanger tubes
    Ayhan, Huseyin
    Sokmen, Cemal Niyazi
    [J]. APPLIED THERMAL ENGINEERING, 2016, 108 : 466 - 474
  • [5] THERMAL HYDRAULICS NUMERICAL SIMULATION AND OPTIMIZED DESIGN OF PASSIVE RESIDUAL HEAT REMOVAL HEAT EXCHANGER IN AP1000
    Xia, Huining
    Lu, Daogang
    Du, Zheng
    Zhang, Yuhao
    Fu, Xiaoliang
    Ma, Zhongying
    Yang, Yanhua
    Liang, Min
    [J]. PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [6] Numerical and experimental study on thermal-hydraulic behaviors in the secondary side of passive residual heat removal heat exchanger
    Tao, Jiaqi
    Gu, Hanyang
    Xiong, Zhenqin
    Jiang, Xing
    Xie, Yongcheng
    [J]. ANNALS OF NUCLEAR ENERGY, 2020, 148
  • [7] Design and analysis of a new passive residual heat removal system
    Lv, Xing
    Peng, Minjun
    Yuan, Xiao
    Xia, Genglei
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2016, 303 : 192 - 202
  • [8] Numerical study on improved design of passive residual heat removal system for China pressurizer reactor
    Li, Yongquan
    Song, Ping
    Feng, Tangtao
    Wang, Mingjun
    Zhang, Dalin
    Tian, Wenxi
    Qiu, Suizheng
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2021, 375
  • [9] Analysis of Influence of Tube Failure on Performance of Passive Residual Heat Removal Heat Exchanger
    Yan, Linfeng
    Wang, Dawei
    Wu, Hsingtzu
    [J]. NUCLEAR TECHNOLOGY, 2022, 208 (12) : 1822 - 1831
  • [10] Introduction of IDINHX, a new heat exchanger for passive decay heat removal
    Sim, Yoon Sub
    [J]. NUCLEAR TECHNOLOGY, 2008, 161 (03) : 299 - 314