Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants

被引:51
|
作者
Bolstad, Kirsten [1 ]
Flatabo, Silje [1 ]
Aadnevik, Daniel [1 ]
Dalehaug, Ingvild [1 ]
Vetti, Nils [2 ]
机构
[1] Haukeland Hosp, Dept Oncol & Med Phys, Bergen, Norway
[2] Haukeland Hosp, Dept Radiol, Bergen, Norway
关键词
Tomography; X-ray computed; metals; artifacts; algorithms; phantoms; diagnostic imaging; orthopedic fixation devices; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY;
D O I
10.1177/0284185117751278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Metal implants may introduce severe artifacts in computed tomography (CT) images. Over the last few years dedicated algorithms have been developed in order to reduce metal artifacts in CT images. Purpose: To investigate and compare metal artifact reduction algorithms (MARs) from four different CT vendors when imaging three different orthopedic metal implants. Material and Methods: Three clinical metal implants were attached to the leg of an anthropomorphic phantom: cobalt-chrome; stainless steel; and titanium. Four commercial MARs were investigated: SmartMAR (GE); O-MAR (Philips); iMAR (Siemens); and SEMAR (Toshiba). The images were evaluated subjectively by three observers and analyzed objectively by calculating the fraction of pixels with CT number above 500 HU in a region of interest around the metal. The average CT number and image noise were also measured. Results: Both subjective evaluation and objective analysis showed that MARs reduced metal artifacts and improved the image quality for CT images containing metal implants of steel and cobalt-chrome. When using MARs on titanium, all MARs introduced new visible artifacts. Conclusion: The effect of MARs varied between CT vendors and different metal implants used in orthopedic surgery. Both in subjective evaluation and objective analysis the effect of applying MARs was most obvious on steel and cobalt-chrome implants when using SEMAR from Toshiba followed by SmartMAR from GE. However, MARs may also introduce new image artifacts especially when used on titanium implants. Therefore, it is important to reconstruct all CT images containing metal with and without MARs.
引用
收藏
页码:1110 / 1118
页数:9
相关论文
共 50 条
  • [1] Usefulness of a Metal Artifact Reduction Algorithm for Orthopedic Implants in Abdominal CT: Phantom and Clinical Study Results
    Jeong, Seonji
    Kim, Se Hyung
    Hwang, Eui Jin
    Shin, Cheong-Il
    Han, Joon Koo
    Choi, Byung Ihn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) : 307 - 317
  • [2] Performance Evaluation of Three Algorithms for Metal Artifact Reduction in CT Imaging
    Du, G.
    Prevrhal, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] A comparison of four algorithms for metal artifact reduction in CT imaging
    Golden, Caroline
    Mazin, Samuel R.
    Boas, F. Edward
    Tye, Grace
    Ghanouni, Pejman
    Gold, Garry
    Sofilos, Marc
    Pelc, Norbert J.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [4] The CT number accuracy of a novel commercial metal artifact reduction algorithm for large orthopedic implants
    Hilgers, Guido
    Nuver, Tonnis
    Minken, Andre
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 274 - 278
  • [5] Metal artifact reduction on musculoskeletal CT: a phantom and clinical study
    Midthun, Petter
    Kirkhus, Eva
    Osteras, Bjorn Helge
    Hoiness, Per Reidar
    England, Andrew
    Johansen, Safora
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [6] Metal artifact reduction on musculoskeletal CT: a phantom and clinical study
    Petter Midthun
    Eva Kirkhus
    Bjørn Helge Østerås
    Per Reidar Høiness
    Andrew England
    Safora Johansen
    European Radiology Experimental, 7
  • [7] Dose Reduction With Dedicated CT Metal Artifact Reduction Algorithm: CT Phantom Study
    Subhas, Naveen
    Pursyko, Camilla P.
    Polster, Joshua M.
    Obuchowski, Nancy A.
    Primak, Andrew N.
    Dong, Frank F.
    Herts, Brian R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (03) : 593 - 600
  • [8] Quantitative analysis of metal artifact reduction in total hip arthroplasty using virtual monochromatic imaging and orthopedic metal artifact reduction, a phantom study
    Selles, Mark
    Stuivenberg, Vera H.
    Wellenberg, Ruud H. H.
    van de Riet, Loes
    Nijholt, Ingrid M.
    van Osch, Jochen A. C.
    van Hamersvelt, Robbert W.
    Leiner, Tim
    Boomsma, Martijn F.
    INSIGHTS INTO IMAGING, 2021, 12 (01)
  • [9] Quantitative analysis of metal artifact reduction in total hip arthroplasty using virtual monochromatic imaging and orthopedic metal artifact reduction, a phantom study
    Mark Selles
    Vera H. Stuivenberg
    Ruud H. H. Wellenberg
    Loes van de Riet
    Ingrid M. Nijholt
    Jochen A. C. van Osch
    Robbert W. van Hamersvelt
    Tim Leiner
    Martijn F. Boomsma
    Insights into Imaging, 12
  • [10] Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy
    Li, Hua
    Noel, Camille
    Chen, Haijian
    Li, H. Harold
    Low, Daniel
    Moore, Kevin
    Klahr, Paul
    Michalski, Jeff
    Gay, Hiram A.
    Thorstad, Wade
    Mutic, Sasa
    MEDICAL PHYSICS, 2012, 39 (12) : 7507 - 7517