Current transducers used in power line measurements

被引:0
|
作者
Milcarz, Sz. [1 ]
Golebiowski, J. [2 ]
机构
[1] Lodz Univ Technol, Fac Elect Lectron Comp & Control Engn E, 18-22 Bohdana Stefanowskiego, PL-90924 Lodz, Poland
[2] Lodz Univ Technol, Dept Semicond & Optoelect Devices, PL-90924 Lodz, Poland
关键词
MEMS; magnetic field; modeling; optoelectronic system; optical fibres;
D O I
10.1117/12.2073032
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
There are many solutions used for current measurements in power lines. The study shows a transducer consisting of a ferromagnetic core, a beam placed in an air-gap and a sensor for optical readout. The beam is made of silicon with a thin 50%Ni50%Fe film. The material of the core is permalloy. A distribution of magnetic field depends on current supplying the power line. The beam is deflected due to magnetic field in the air-gap. A deflection of the beam is measured by the optical fibre sensor. Its advantage is simple design, high precision of processing, non-electric transmission, low costs and ability of a non-contact measurement. Comsol Multiphysics 4.4 and Magnetic Fields Module (mef) were used for modeling. An influence of magnetic circuit's materials and dimensions of the ferromagnetic core and the air-gap were tested in order to determine the most sufficient distribution of magnetic field in the air-gap. The study shows results of the modeling of the transducer compared to practical results for a similar construction scaled down to lower current values.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Transducers for systems of on-line diagnostics for nuclear power stations with VVER reactors
    VNIIAES, Moscow, Russia
    Teploenerg, 6 (33-37):
  • [42] On line PD measurements and diagnosis on power transformers
    Aschenbrenner, D
    Kranz, HG
    Rutgers, WR
    van den Aardweg, P
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 216 - 222
  • [43] Line Current Stabilizer Based on a Current Active Power Filter
    Vazquez, N.
    Rico, D.
    Hernandez, C.
    Orosco, R.
    Arau, J.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5, 2008, : 906 - 910
  • [44] Reviewing current transformers and current transducers
    McLyman, Colonel W. T.
    2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, : 360 - 365
  • [45] Analysis of CSMA/CA Used in Power Line Communication
    Koutny, Martin
    Mlynek, Petr
    Misurec, Jiri
    2013 36TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2013, : 385 - 388
  • [46] CHARACTERISTICS OF A POWER-LINE USED AS A VLF ANTENNA
    DAZEY, MH
    KOONS, HC
    RADIO SCIENCE, 1982, 17 (03) : 589 - 597
  • [47] A SURVEY OF CURRENT SHUNTS FOR AC POWER MEASUREMENTS
    Tarasso, V.
    Zachovalova, V. N.
    Garcocz, M.
    Lind, K.
    Mansten, T.
    Pogliano, U.
    Rietveld, G.
    Voljc, B.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 231 - 232
  • [48] Current Measurements in High Performance Polymers Used in Aeronautic Cables
    Ndongo Diaw, El Hadji
    Roy, Severine Le
    Teyssedre, Gilbert
    Aubert, Eddy
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (06) : 2195 - 2202
  • [49] PICOSTRAIN MEASUREMENTS WITH PIEZOELECTRIC TRANSDUCERS
    FORWARD, RL
    JOURNAL OF APPLIED PHYSICS, 1980, 51 (11) : 5601 - 5603
  • [50] Ultrasonic measurements on micromachined transducers
    Andrews, MK
    Harris, PD
    Turner, GC
    EUROSENSORS XII, VOLS 1 AND 2, 1998, : 117 - 120