Current transducers used in power line measurements

被引:0
|
作者
Milcarz, Sz. [1 ]
Golebiowski, J. [2 ]
机构
[1] Lodz Univ Technol, Fac Elect Lectron Comp & Control Engn E, 18-22 Bohdana Stefanowskiego, PL-90924 Lodz, Poland
[2] Lodz Univ Technol, Dept Semicond & Optoelect Devices, PL-90924 Lodz, Poland
关键词
MEMS; magnetic field; modeling; optoelectronic system; optical fibres;
D O I
10.1117/12.2073032
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
There are many solutions used for current measurements in power lines. The study shows a transducer consisting of a ferromagnetic core, a beam placed in an air-gap and a sensor for optical readout. The beam is made of silicon with a thin 50%Ni50%Fe film. The material of the core is permalloy. A distribution of magnetic field depends on current supplying the power line. The beam is deflected due to magnetic field in the air-gap. A deflection of the beam is measured by the optical fibre sensor. Its advantage is simple design, high precision of processing, non-electric transmission, low costs and ability of a non-contact measurement. Comsol Multiphysics 4.4 and Magnetic Fields Module (mef) were used for modeling. An influence of magnetic circuit's materials and dimensions of the ferromagnetic core and the air-gap were tested in order to determine the most sufficient distribution of magnetic field in the air-gap. The study shows results of the modeling of the transducer compared to practical results for a similar construction scaled down to lower current values.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Effect of power disturbances on electromagnetic current-to-voltage transducers characteristics
    Jalmuzny, Wieslaw
    Lesniewska, Elzbieta
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (09): : 60 - 62
  • [32] MEASUREMENTS FOR ELECTROACOUSTIC TRANSDUCERS
    ENDRES, W
    NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1978, 31 (04): : 258 - 258
  • [33] INVESTIGATION OF CURRENT-COLLECTING DEVICES USED IN MEASUREMENTS
    GULYAEV, GA
    MEASUREMENT TECHNIQUES-USSR, 1965, (05): : 404 - &
  • [34] Measurement uncertainty of torque measurements with rotating torque transducers in power test stands
    Wegener, Georg
    Andrae, Juergen
    MEASUREMENT, 2007, 40 (7-8) : 803 - 810
  • [35] Voltage Transients Measurements and Power Line Communication
    Ahonen, Mikko
    Koppel, Tarmo
    2016 57TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2016,
  • [36] Optimal Phase on Biaxial Driven Transducers Based only on Electrical Power Measurements
    Delgado, Sagid
    Curiel, Laura
    Rubel, Oleg
    Da Silva, Geovane
    Pichardo, Samuel
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [37] Power System State Estimation with Line Measurements
    Zhang, Yu
    Madani, Ramtin
    Lavaei, Javad
    2016 IEEE 55TH CONFERENCE ON DECISION AND CONTROL (CDC), 2016, : 2403 - 2410
  • [38] Modeling and measurements for power line communication systems
    Luo, W. Q.
    Tan, S. Y.
    Tan, Boon Tiong
    2005 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS, VOLS 1-5, 2005, : 3109 - +
  • [39] Evaluation of power line measurements of the link with cancer
    Ashley, JR
    Beatie, RE
    Heneage, JF
    PROCEEDINGS OF THE IEEE SOUTHEASTCON '96: BRINGING TOGETHER EDUCATION, SCIENCE AND TECHNOLOGY, 1996, : 41 - 50
  • [40] Power line interference in ambulatory biopotential measurements
    Serrano, RE
    Gasulla, M
    Casas, O
    Pallàs-Areny, R
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3024 - 3027