Motion artifact suppression in full-field optical coherence tomography

被引:37
|
作者
Sacchet, Delphine [1 ]
Brzezinski, Michal [1 ]
Moreau, Julien [1 ]
Georges, Patrick [1 ]
Dubois, Arnaud [1 ]
机构
[1] Univ Paris 11, CNRS, UMR 8501, Inst Opt,Lab Charles Fabry, F-91127 Palaiseau, France
关键词
ULTRAHIGH-RESOLUTION; THERMAL-LIGHT; HIGH-SPEED; LINNIK MICROSCOPE; INTERFEROMETRY;
D O I
10.1364/AO.49.001480
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Significant motion artifacts limit the performance of conventional full-field optical coherence tomography (FF-OCT) for in vivo imaging. We present a theoretical and experimental study of those limitations. A new FF-OCT system suppressing most of artifacts due to sample motions is demonstrated using instantaneous phase shifting with nonpolarizing optics and pulsed illumination. The experimental setup is based on a Linnik-type interferometer illuminated by the superluminescence emission from a Ti:Al2O3 waveguide crystal. En face tomographic images are calculated as a combination of two phase-opposed interferometric images acquired simultaneously by two CCD cameras placed at both outputs of the interferometer, with a spatial resolution of 0.8 mu m x 1.6 mu m (axial x transverse) and a detection sensitivity of similar to 60 dB. (C) 2010 Optical Society of America
引用
收藏
页码:1480 / 1488
页数:9
相关论文
共 50 条
  • [31] Experimental demonstration of full-field quantum optical coherence tomography
    Ibarra-Borja, Zeferino
    Sevilla-Gutierrez, Carlos
    Ramirez-Alarcon, Roberto
    Cruz-Ramirez, Hector
    U'Ren, Alfred B.
    PHOTONICS RESEARCH, 2020, 8 (01) : 51 - 56
  • [32] Ultrahigh-resolution full-field optical coherence tomography
    Dubois, A
    Grieve, K
    Moneron, G
    Lecaque, R
    Vabre, L
    Boccara, C
    APPLIED OPTICS, 2004, 43 (14) : 2874 - 2883
  • [33] Human trabeculum imaging with full-field optical coherence tomography
    Stephane, Bertin
    Zwillinger, Stephanie
    Paques, Michel
    Baudouin, Christophe
    Labbe, Antoine
    Borderie, Vincent M.
    Grieve, Kate
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [34] Effects of temporal and spatial coherence on resolution in full-field optical coherence tomography
    Gao, Wanrong
    JOURNAL OF MODERN OPTICS, 2015, 62 (21) : 1764 - 1774
  • [35] Image contrast reduction mechanism in full-field optical coherence tomography
    Gao, Wanrong
    JOURNAL OF MICROSCOPY, 2016, 261 (03) : 199 - 216
  • [36] Assessment of Oocyte Quality Based on full-Field Optical Coherence Tomography
    Liu Mei-Jun
    Yu Ji
    Tian Ning
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2020, 47 (12) : 1311 - 1318
  • [37] Full-field optical coherence tomography for the diagnosis of giant cell arteritis
    Maldiney, Thomas
    Greigert, Helene
    Martin, Laurent
    Benoit, Emilie
    Creuzot-Garcher, Catherine
    Gabrielle, Pierre-Henry
    Chassot, Jean-Marie
    Boccara, Claude
    Balvay, Daniel
    Tavitian, Bertrand
    Clement, Olivier
    Audia, Sylvain
    Bonnotte, Bernard
    Samson, Maxime
    PLOS ONE, 2020, 15 (08):
  • [38] Image contrast correction method in full-field optical coherence tomography
    Mu, Ning
    Gao, Wanrong
    Zhou, Yawen
    OPTICAL ENGINEERING, 2019, 58 (07)
  • [39] A method of improving imaging quality of full-field optical coherence tomography
    Zhu, Yue
    Gao, Wanrong
    Guo, Yingcheng
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (05):
  • [40] Human graft cornea imaging with full-field optical coherence tomography
    Ghouali, Wajdene
    Grieve, Kate
    Sandali, Otman
    Basli, Elena
    Bullet, Julien
    Laroche, Laurent
    Borderie, Vincent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)