Effects of temporal and spatial coherence on resolution in full-field optical coherence tomography

被引:30
|
作者
Gao, Wanrong [1 ]
机构
[1] Nanjing Univ Sci & Technol, Dept Opt Engn, Nanjing, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
lateral resolution; depth resolution; full-field optical coherence tomography; IN-VIVO; ELECTROMAGNETIC DIFFRACTION; REFRACTIVE-INDEX; SCATTERING; FLUORESCENCE; MICROSCOPY; LIGHT; TISSUE; OCT; TECHNOLOGY;
D O I
10.1080/09500340.2014.952689
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The contrast enhanced imaging of microscopic structures of tissue and the high-resolution optical sectional imaging of thin slices within tissue are two main advantages of full-field optical coherence tomography (FFOCT) over the conventional optical microscopy. In this work, first a detailed description of the development of FFOCT technique is reviewed. The imaging signal model of FFOCT is then described, which reveals the roles of both the light-intensity distribution in the pupil plane of the objective lenses and the light spectrum of the source on the system resolution. Then the effects of the temporal and spatial coherence on the lateral resolution and depth resolution of FFOCT are considered. Finally, the change of separation between the temporal coherence envelope and the longitudinal spatial coherence envelope is analyzed induced by the mismatch of the refractive index of tissue and the surrounding medium.
引用
收藏
页码:1764 / 1774
页数:11
相关论文
共 50 条
  • [1] Spatial and temporal coherence effects in interference microscopy and full-field optical coherence tomography
    Abdulhalim, Ibrahim
    ANNALEN DER PHYSIK, 2012, 524 (12) : 787 - 804
  • [2] Ultrahigh-resolution full-field optical coherence tomography
    Dubois, A
    Grieve, K
    Moneron, G
    Lecaque, R
    Vabre, L
    Boccara, C
    APPLIED OPTICS, 2004, 43 (14) : 2874 - 2883
  • [3] Full-field optical coherence tomography using a spatial filter
    Liu, XP
    Chang, S
    Cai, XY
    Grover, CP
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION VI, 2003, 5174 : 179 - 186
  • [4] Adaptive coherence volume in full-field optical coherence tomography
    Mekhileri, Naveen Vijayan
    Andrique, Laetitia
    Recher, Gaelle
    Nassoy, Pierre
    Badon, Amaury
    OSA CONTINUUM, 2021, 4 (11): : 2805 - 2812
  • [5] Research on full-field optical coherence tomography
    School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing
    210094, China
    不详
    214041, China
    Tongxin Xuebao, 12 (121-127):
  • [6] Stroboscopic ultrahigh-resolution full-field optical coherence tomography
    Moneron, G
    Boccara, AC
    Dubois, A
    OPTICS LETTERS, 2005, 30 (11) : 1351 - 1353
  • [7] Full-field optical coherence tomography system with controllable longitudinal resolution
    Nitta, Kouichi
    Li, Tingyu
    Motoyama, Toshiki
    Matoba, Osamu
    Yoshimura, Takeaki
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (11): : 8897 - 8903
  • [8] Full-field optical coherence tomography system with controllable longitudinal resolution
    Nitta, Kouichi
    Li, Tingyu
    Motoyama, Toshiki
    Matoba, Osamu
    Yoshimura, Takeaki
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (11): : 8897 - 8903
  • [9] Full-field optical coherence microscopy with optimized ultrahigh spatial resolution
    Federici, Antoine
    Dubois, Arnaud
    OPTICS LETTERS, 2015, 40 (22) : 5347 - 5350
  • [10] Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography
    Safrani, Avner
    Abdulhalim, Ibrahim
    APPLIED OPTICS, 2011, 50 (18) : 3021 - 3027