Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography

被引:40
|
作者
Safrani, Avner [1 ]
Abdulhalim, Ibrahim
机构
[1] Ben Gurion Univ Negev, Dept Electro Opt Engn, IL-84105 Beer Sheva, Israel
关键词
THERMAL-LIGHT; INTERFERENCE MICROSCOPY; LINNIK MICROSCOPE;
D O I
10.1364/AO.50.003021
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Longitudinal spatial coherence (LSC) is determined by the spatial frequency content of an optical beam. The use of lenses with a high numerical aperture (NA) in full-field optical coherence tomography and a narrowband light source makes the LSC length much shorter than the temporal coherence length, hence suggesting that high-resolution 3D images of biological and multilayered samples can be obtained based on the low LSC. A simplified model is derived, supported by experimental results, which describes the expected interference output signal of multilayered samples when high-NA lenses are used together with a narrowband light source. An expression for the correction factor for the layer thickness determination is found valid for high-NA objectives. Additionally, the method was applied to a strongly scattering layer, demonstrating the potential of this method for high-resolution imaging of scattering media. (C) 2011 Optical Society of America
引用
收藏
页码:3021 / 3027
页数:7
相关论文
共 50 条
  • [1] Effects of temporal and spatial coherence on resolution in full-field optical coherence tomography
    Gao, Wanrong
    JOURNAL OF MODERN OPTICS, 2015, 62 (21) : 1764 - 1774
  • [2] Full-field optical coherence tomography using a spatial filter
    Liu, XP
    Chang, S
    Cai, XY
    Grover, CP
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION VI, 2003, 5174 : 179 - 186
  • [3] Spatial and temporal coherence effects in interference microscopy and full-field optical coherence tomography
    Abdulhalim, Ibrahim
    ANNALEN DER PHYSIK, 2012, 524 (12) : 787 - 804
  • [4] Adaptive coherence volume in full-field optical coherence tomography
    Mekhileri, Naveen Vijayan
    Andrique, Laetitia
    Recher, Gaelle
    Nassoy, Pierre
    Badon, Amaury
    OSA CONTINUUM, 2021, 4 (11): : 2805 - 2812
  • [5] Research on full-field optical coherence tomography
    School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing
    210094, China
    不详
    214041, China
    Tongxin Xuebao, 12 (121-127):
  • [6] Large area full-field Optical Coherence Tomography
    Chang, Shoude
    Sherif, Sherif
    Flueraru, Costel
    PHOTONICS NORTH 2006, PTS 1 AND 2, 2006, 6343
  • [7] Adaptive optics full-field optical coherence tomography
    Xiao, Peng
    Fink, Mathias
    Boccara, Albert Claude
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (12)
  • [8] Manifestation of aberrations in full-field optical coherence tomography
    Barolle, Victor
    Scholler, Jules
    Mece, Pedro
    Chassot, Jean-Marie
    Groux, Kassandra
    Fink, Mathias
    Boccara, A. Claude
    Aubry, Alexandre
    OPTICS EXPRESS, 2021, 29 (14) : 22044 - 22065
  • [9] Full-field optical coherence tomography with thermal light
    Laude, Blandine
    De Martino, Antonello
    Drévillon, Bernard
    Benattar, Laurence
    Schwartz, Laurent
    Applied Optics, 2002, 41 (31): : 6637 - 6645
  • [10] Full-field optical coherence tomography with thermal light
    Laude, B
    De Martino, A
    Drévillon, B
    Benattar, L
    Schwartz, L
    APPLIED OPTICS, 2002, 41 (31) : 6637 - 6645