Biomechanical Comparison of Titanium Locking Fragment-Specific and Volar Locking Plates for AO B1 and B2 Fractures of the Distal Radius

被引:1
|
作者
Martin, Dennis P. [1 ]
Park, Andrew G. [1 ]
Jamison, David [2 ]
Jones, Christopher M. [1 ]
Ilyas, Asif M. [1 ]
机构
[1] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Dept Orthoped Surg, Rothman Inst, 125 S 9th St,Suite 1000, Philadelphia, PA 19107 USA
[2] Villanova Univ, Dept Mech Engn, Villanova, PA 19085 USA
来源
关键词
Distal radius; dorsal shear; fragment-specific; radial styloid; volar locking; LOW-PROFILE DORSAL; DISPLACED FRACTURES; SURGICAL-TREATMENT; FIXATION; PART; COMPLICATIONS; STABILITY; FORCES; SYSTEM; SCREW;
D O I
10.1016/j.jhsa.2019.02.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose This biomechanical study compared the stability of volar locking plates (VLPs) and locking fragment-specific (LFS) dorsal and radial styloid plates for the fixation of dorsal (AO 23-B2) and radial styloid (AO 23-B1) shear fractures of the distal radius, respectively. Methods Two groups of 6 composite radii were fixed with a VLP or an LFS dorsal plate over a simulated dorsal shear fracture. Two additional groups of 6 radii received the same VLP or an LFS radial plate to fix a radial styloid fracture. Each plated radius was tested under cyclic axial compression by a servohydraulic testing machine that recorded axial displacement per cycle. Construct stiffness was calculated from the slope of the force-displacement curve. Results In the dorsal shear fracture model, the dorsal LFS plate exhibited less displacement than the VLP (0.32 +/- 0.04 vs 0.43 +/- 0.07 mm, respectively) and showed greater average stiffness (645 +/- 64 vs 433 +/- 88 N/mm, respectively). Plate type was responsible for 53.1% of the variation in displacement and 68.6% of the variation in stiffness. In the radial styloid fracture model, variations due to number of cycles elapsed and plate type were similar for displacement and stiffness in both groups. The average stiffness during cyclical nondestructive testing was 566 +/- 45 and 573 +/- 60 N/mm for VLP and LFS radial plating groups, respectively. Conclusions For AO 23-B2 (dorsal rim) fractures, the dorsal LFS plates exhibited significantly less displacement and greater stiffness in axial loading than VLPs. ForAO23-B1 (radial styloid) fractures, the VLP displayed similar displacement and stiffness to the radial LFS plates. Copyright (C) 2019 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:1093.e1 / 1093.e8
页数:8
相关论文
共 50 条
  • [21] Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial
    Gregory B Couzens
    Susan E Peters
    Kenneth Cutbush
    Benjamin Hope
    Fraser Taylor
    Christopher D James
    Carly R Rankin
    Mark Ross
    BMC Musculoskeletal Disorders, 15
  • [22] Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial
    Couzens, Gregory B.
    Peters, Susan E.
    Cutbush, Kenneth
    Hope, Benjamin
    Taylor, Fraser
    James, Christopher D.
    Rankin, Carly R.
    Ross, Mark
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [23] Can the Use of Variable-Angle Volar Locking Plates Compensate for Suboptimal Plate Positioning in Unstable Distal Radius Fractures? A Biomechanical Study
    Hart, Adam
    Collins, Melissa
    Chhatwal, Dane
    Steffen, Thomas
    Harvey, Edward J.
    Martineau, Paul A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (01) : E1 - E6
  • [24] Comparison of AO Type-B and Type-C Volar Shearing Fractures of the Distal Part of the Radius
    Souer, J. Sebastiaan
    Ring, David
    Jupiter, Jesse B.
    Matschke, Stefan
    Audige, Laurent
    Marent-Huber, Marta
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11): : 2605 - 2611
  • [25] Volar versus dorsal latest-generation variable-angle locking plates for the fixation of AO type 23C 2.1 distal radius fractures: A biomechanical study in cadavers
    Rausch, Sascha
    Schlonski, Olaf
    Klos, Kajetan
    Gras, Florian
    Gueorguiev, Boyko
    Hofmann, Gunther O.
    Mueckley, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 523 - 526
  • [26] Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate
    Strauss, Eric J.
    Banerjee, Devraj
    Kummer, Frederick J.
    Tejwani, Nirmal C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (04): : 975 - 981
  • [27] Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model
    Grindel, Steven I.
    Wang, Mei
    Gerlach, Matthew
    McGrady, Linda M.
    Brown, Susan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02): : 194 - 199
  • [28] Comparative study of type B distal radius fractures with and without lunate facet involvement treated by volar locking plate, an observational study
    Zhang, Xiong
    Zhao, Yan
    Hu, Chunhe
    Yu, Kunlun
    Bai, Jiangbo
    Tian, Dehu
    Xu, Yi
    Zhang, Bing
    INTERNATIONAL JOURNAL OF SURGERY, 2017, 44 : 317 - 323
  • [29] Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation - a biomechanical study
    Gordon, Katharina
    Winkler, Martin
    Hofstaedter, Thomas
    Dorn, Ulrich
    Augat, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S51 - S57
  • [30] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355