Xenon Ventilation Imaging Using Dual-Energy Computed Tomography in Asthmatics Initial Experience

被引:71
|
作者
Chae, Eun Jin [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Lee, Jeongjin [3 ]
Kim, Namkug [1 ,2 ]
Goo, Hyun Woo [1 ,2 ]
Lee, Hyun Joo [1 ,2 ]
Lee, Choong Wook [1 ,2 ]
Ra, Seung Won [4 ]
Oh, Yeon-Mok [4 ]
Cho, You Sook [5 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Catholic Univ Korea, Dept Digital Media, Bucheon Si, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Pulm & Crit Care Med, Seoul 138736, South Korea
[5] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Allergy & Clin Immunol,Clin Res Ctr Chron Ob, Seoul 138736, South Korea
关键词
xenon; asthma; ventilation; dual-energy CT; HE-3; MAGNETIC-RESONANCE; LOCAL PULMONARY VENTILATION; AIRWAY WALL THICKNESS; HALF-MAXIMUM METHOD; SEMIAUTOMATIC MEASUREMENT; MEASUREMENT ACCURACY; FLOW OBSTRUCTION; CT; LUNG; METHACHOLINE;
D O I
10.1097/RLI.0b013e3181dfdae0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of xenon ventilation computed tomography (CT) for evaluating ventilation abnormality in asthmatics. Materials and Methods: Twenty-two, stable asthmatics (M: F = 10: 12; mean age, 57.6) were included. Single-phase, whole-thorax, dual-energy CT was performed using dual-source CT (Somatom Definition, Siemens) after subjects had inhaled 30% xenon for 90 seconds. Parameters include 512 x 512 matrix; 14 x 1.2 mm collimation; 40/140 eff. mAs at 140/80 kV; 0.45 pitch; and 0.33 seconds rotation time. On the color-coded xenon map, the extent of the ventilation defect was visually assessed using a 5-point scale in each lobe (0, absent defect; 1, 0%-25%; 2, 25%-50%; 3, 50%-75%; and 4, 75%-100%), which was defined as defect score. On the weighted average image, airway wall dimensions were measured at 4 segmental bronchi in both upper and lower lobes. Patients were classified into a defect group and a defect-free group based on the presence of defects shown on the xenon map. Pulmonary function test parameters and airway wall dimensions were compared in those 2 groups. Correlation analyses between the defect score, pulmonary function test, and airway wall dimensions were performed. Results: Sixteen asthmatics showed peripheral ventilation defects on the xenon map (defect score, 6.6 +/- 4.2). The defect group had a significantly lower forced expiratory volume in 1 second (FEV1) and thicker airway wall than that of the defect-free group (P = 0.04 and 0.02, respectively). The defect score correlated negatively with a ratio of FEV1 and forced vital capacity (FEV1/FVC) (r =-0.44, P = 0.04) and corrected diffusing capacity (r =-0.76, P = 0.04) and correlated positively with total lung capacity, functional residual volume, and residual volume (r = 0.90, P < 0.005; r = 0.99, P < 0.001; r = 0.88, P = 0.008, respectively). Conclusions: The ventilation defects appeared on xenon ventilation CT in asthmatics with more severe airflow limitation and airway wall thickening. The extent of the ventilation defects showed correlations with parameters of pulmonary function test.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [41] Dual-energy computed tomography diagnostics for gout
    Rech, H. J.
    Cavallaro, A.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (07): : 580 - 588
  • [42] Characteristics of Chinese Costal Cartilage and Costa Calcification Using Dual-Energy Computed Tomography Imaging
    Shanyong Zhang
    Jinze Zhen
    Huiping Li
    Shoufu Sun
    Huawei Wu
    Pei Shen
    Zengai Chen
    Chi Yang
    Scientific Reports, 7
  • [43] Advances for Pulmonary Functional Imaging: Dual-Energy Computed Tomography for Pulmonary Functional Imaging
    Ozawa, Yoshiyuki
    Ohno, Yoshiharu
    Nagata, Hiroyuki
    Tamokami, Keigo
    Nishikimi, Keitaro
    Oshima, Yuka
    Hamabuchi, Nayu
    Matsuyama, Takahiro
    Ueda, Takahiro
    Toyama, Hiroshi
    DIAGNOSTICS, 2023, 13 (13)
  • [44] Dual-energy computed tomography of canine uroliths
    Nykamp, Stephanie G.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2017, 78 (10) : 1150 - 1155
  • [45] Dual-energy computed tomography in pulmonary embolism
    Lu, G-M
    Wu, S-Y
    Yeh, B. M.
    Zhang, L-J
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (992): : 707 - 718
  • [46] Pediatric Applications of Dual-Energy Computed Tomography
    Pena-Trujillo, Valeria
    Gallo-Bernal, Sebastian
    Tung, Erik L.
    Gee, Michael S.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1069 - 1083
  • [47] Dual-Energy Computed Tomography : Technological Considerations
    Chung, Ryan
    Dane, Bari
    Yeh, Benjamin M.
    Morgan, Desiree E.
    Sahani, Dushyant V.
    Kambadakone, Avinash
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 945 - 961
  • [48] Dual-energy Computed Tomography Applications in Uroradiology
    Park, Jong
    Chandarana, Hersh
    Macari, Michael
    Megibow, Alec J.
    CURRENT UROLOGY REPORTS, 2012, 13 (01) : 55 - 62
  • [49] Dual-energy computed tomography: what is it useful for?
    Delgado Sanchez-Gracian, C.
    Martinez Rodriguez, C.
    Trinidad Lopez, C.
    RADIOLOGIA, 2013, 55 (04): : 346 - 352
  • [50] Review of dual-energy computed tomography techniques
    Engler, Philip, 1600, (48):