Xenon Ventilation Imaging Using Dual-Energy Computed Tomography in Asthmatics Initial Experience

被引:71
|
作者
Chae, Eun Jin [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Lee, Jeongjin [3 ]
Kim, Namkug [1 ,2 ]
Goo, Hyun Woo [1 ,2 ]
Lee, Hyun Joo [1 ,2 ]
Lee, Choong Wook [1 ,2 ]
Ra, Seung Won [4 ]
Oh, Yeon-Mok [4 ]
Cho, You Sook [5 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Catholic Univ Korea, Dept Digital Media, Bucheon Si, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Pulm & Crit Care Med, Seoul 138736, South Korea
[5] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Allergy & Clin Immunol,Clin Res Ctr Chron Ob, Seoul 138736, South Korea
关键词
xenon; asthma; ventilation; dual-energy CT; HE-3; MAGNETIC-RESONANCE; LOCAL PULMONARY VENTILATION; AIRWAY WALL THICKNESS; HALF-MAXIMUM METHOD; SEMIAUTOMATIC MEASUREMENT; MEASUREMENT ACCURACY; FLOW OBSTRUCTION; CT; LUNG; METHACHOLINE;
D O I
10.1097/RLI.0b013e3181dfdae0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of xenon ventilation computed tomography (CT) for evaluating ventilation abnormality in asthmatics. Materials and Methods: Twenty-two, stable asthmatics (M: F = 10: 12; mean age, 57.6) were included. Single-phase, whole-thorax, dual-energy CT was performed using dual-source CT (Somatom Definition, Siemens) after subjects had inhaled 30% xenon for 90 seconds. Parameters include 512 x 512 matrix; 14 x 1.2 mm collimation; 40/140 eff. mAs at 140/80 kV; 0.45 pitch; and 0.33 seconds rotation time. On the color-coded xenon map, the extent of the ventilation defect was visually assessed using a 5-point scale in each lobe (0, absent defect; 1, 0%-25%; 2, 25%-50%; 3, 50%-75%; and 4, 75%-100%), which was defined as defect score. On the weighted average image, airway wall dimensions were measured at 4 segmental bronchi in both upper and lower lobes. Patients were classified into a defect group and a defect-free group based on the presence of defects shown on the xenon map. Pulmonary function test parameters and airway wall dimensions were compared in those 2 groups. Correlation analyses between the defect score, pulmonary function test, and airway wall dimensions were performed. Results: Sixteen asthmatics showed peripheral ventilation defects on the xenon map (defect score, 6.6 +/- 4.2). The defect group had a significantly lower forced expiratory volume in 1 second (FEV1) and thicker airway wall than that of the defect-free group (P = 0.04 and 0.02, respectively). The defect score correlated negatively with a ratio of FEV1 and forced vital capacity (FEV1/FVC) (r =-0.44, P = 0.04) and corrected diffusing capacity (r =-0.76, P = 0.04) and correlated positively with total lung capacity, functional residual volume, and residual volume (r = 0.90, P < 0.005; r = 0.99, P < 0.001; r = 0.88, P = 0.008, respectively). Conclusions: The ventilation defects appeared on xenon ventilation CT in asthmatics with more severe airflow limitation and airway wall thickening. The extent of the ventilation defects showed correlations with parameters of pulmonary function test.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [21] Myocardial perfusion imaging using dual-energy computed tomography: a clinical case
    Pontone, Gianluca
    Grancini, Luca
    Andreini, Daniele
    Pepi, Mauro
    Bartorelli, Antonio L.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (08) : 835 - 835
  • [22] Krypton Ventilation Imaging Using Dual-Energy CT in Chronic Obstructive Pulmonary Disease Patients: Initial Experience
    Hachulla, Anne-Lise
    Pontana, Francois
    Wemeau-Stervinou, Lidwine
    Khung, Suonita
    Faivre, Jean-Baptiste
    Wallaert, Benoit
    Cazaubon, Jean-Francois
    Duhamel, Alain
    Perez, Thierry
    Devos, Patrick
    Remy, Jacques
    Remy-Jardin, Martine
    RADIOLOGY, 2012, 263 (01) : 253 - 259
  • [23] Correlation Between Dual-Energy Computed Tomography Single Scan and Computed Tomography Perfusion for Pancreatic Cancer Patients: Initial Experience
    Bao, Jiaqi
    Liu, Aishi
    Zhao, Changhong
    Hao, Fen'e
    Su, Xiulan
    Bao, Lili
    Zhao, Lei
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (04) : 599 - 604
  • [24] Gastrointestinal Imaging: Emerging Role of Dual-Energy Computed Tomography
    Ali I.T.
    Thomas C.
    Elbanna K.Y.
    Mohammed M.F.
    Berger F.H.
    Khosa F.
    Current Radiology Reports, 5 (8)
  • [25] Volume-based quantification using dual-energy computed tomography in the differentiation of thymic epithelial tumours: an initial experience
    Chang, Suyon
    Hur, Jin
    Im, Dong Jin
    Suh, Young Joo
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Kim, Young Jin
    Han, Kyunghwa
    Kim, Dae Joon
    Lee, Chang Young
    Shin, Ha Young
    Choi, Byoung Wook
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 1992 - 2001
  • [26] Volume-based quantification using dual-energy computed tomography in the differentiation of thymic epithelial tumours: an initial experience
    Suyon Chang
    Jin Hur
    Dong Jin Im
    Young Joo Suh
    Yoo Jin Hong
    Hye-Jeong Lee
    Young Jin Kim
    Kyunghwa Han
    Dae Joon Kim
    Chang Young Lee
    Ha Young Shin
    Byoung Wook Choi
    European Radiology, 2017, 27 : 1992 - 2001
  • [27] Introduction to Dual-Energy Computed Tomography
    Elster, Allen D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 823 - 823
  • [28] Optimal Contrast of Computed Tomography Portal Venography Using Dual-Energy Computed Tomography
    Wang, Qi
    Shi, Gaofeng
    Liu, Xiang
    Wu, Runze
    Wang, Shijie
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (02) : 142 - 148
  • [29] Noise reduction in dual-energy computed tomography virtual monoenergetic imaging
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 104 - 113
  • [30] Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging
    Kim, Cherry
    Kim, Wooil
    Park, Sung-Joon
    Lee, Young Hen
    Hwang, Sung Ho
    Yong, Hwan Seok
    Oh, Yu-Whan
    Kang, Eun-Young
    Lee, Ki Yeol
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (07) : 838 - 850