Cervical artery dissection: Improved diagnosis by B-Flow ultrasound

被引:0
|
作者
Clevert, D. -A.
Jung, E. M.
Johnson, T.
Kubale, R.
Rupp, N.
Schoenberg, S. O.
Reiser, M.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Inst Diagnost Radiol, Passau, Germany
[3] Inst Radiol, Pirmasens, Germany
关键词
B-Flow imaging; carotid artery; vertebral artery;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The objective of this study was to evaluate the efficiency of B-Flow ultrasound in diagnosing supraaortic vessel dissections compared with other ultrasound techniques including B scan, Color-Coded Doppler (CCDS) and Power Doppler (PD). Materials and methods: Eighty-eight patients with suspected arterial dissection of the neck vessels were included in this prospective trial. All patients were examined using B scan, Color-Coded Doppler sonography and Power Doppler. After documentation of the diagnoses, the patients were additionally examined by B-Flow ultrasound. Contrast-enhanced magnetic resonance angiography (MRA) was used as reference standard in all cases. Results: Dissections of the carotid artery (n=19) and of the vertebral artery (n=35) were found in 44 patients. B-Flow imaging identified 52 of 54 arterial dissections that were confirmed by MRA. There were no false-positive diagnoses in ultrasound examination. The sensitivity of ultrasound examination using B scan, CCDS and PD in detecting all dissections was 95.9% and 99.1% with additional B-Flow examination. Sensitivity using B-Flow increased from 98.3% to 100% for carotid dissections and from 93.3% to 94.3% for vertebral artery dissections. Due to the lack of overwriting artifacts, B-Flow imaging detected residual flow within the false lumen more precisely. The reduced effect of the ultrasound probe angle facilitated imaging of fissures, membranes and low flow phenomena and improved the identification of low-reflection wall structures. The cine mode of the B-Flow showed undulating membrane movement most clearly. Contrast-enhanced MRA in conjunction with axial T1 and T2 weighted sequences enabled the best visualization of intramural hematomas. Conclusion: B-Flow imaging can significantly increase the sensitivity of ultrasound examination for dissections of the neck vessels. It also improves the visualization of flow within the true and false lumen, of hypoechoic thrombi and of intramural hematoma.
引用
收藏
页码:141 / 153
页数:13
相关论文
共 50 条
  • [1] Improved diagnosis of vascular neck dissection by ultrasound B-flow imaging
    Clevert, DA
    Jung, EM
    Reiser, MF
    Rupp, N
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 122 - 122
  • [2] Improved diagnosis of vascular neck dissection by ultrasound B-flow imaging
    Clevert, DA
    Jung, EM
    Rupp, N
    Reiser, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 132 - 132
  • [3] B-Flow imaging in low cervical internal carotid artery dissection
    Tola, M
    Yurdakul, M
    Cumhur, T
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (11) : 1497 - 1502
  • [4] Ultrasound B-flow Imaging of Spontaneous Internal Carotid Artery Dissection
    Titianova, E.
    Ramshev, K.
    Karakaneva, S.
    Petrov, I.
    Ivanov, A.
    NEUROSONOLOGY AND CEREBRAL HEMODYNAMICS, 2008, 4 (01): : 19 - 24
  • [5] Improved diagnosis of vessel dissections by ultrasound B-flow imaging
    Clevert, DA
    Jung, EM
    Reiser, MF
    Rupp, N
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 1 - 2
  • [6] Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography
    Clevert, DA
    Rupp, N
    Reiser, M
    Jung, EM
    EUROPEAN RADIOLOGY, 2005, 15 (02) : 342 - 347
  • [7] Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography
    D.-A. Clevert
    N. Rupp
    M. Reiser
    E. M. Jung
    European Radiology, 2005, 15 : 342 - 347
  • [8] Improved evaluation of stenoses of hemodialysis fistulas by B-Flow ultrasound
    Jung, EM
    Kubale, R
    Clevert, DA
    Rupp, N
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (03): : 387 - 392
  • [9] B-flow and color-coded B-flow in sonographic diagnosis of filiform stenosis of the internal carotid artery
    Jung, EM
    Clevert, DA
    Rupp, N
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (09): : 1251 - 1258
  • [10] B-flow in sonographic diagnosis of filiform stenosis/occlusion of the internal carotid artery
    Jung, E
    Clevert, D
    Rupp, N
    RADIOLOGY, 2002, 225 : 277 - 277