3D fitting accuracy evaluation of CAD/CAM copings - comparison with spacer design settings

被引:0
|
作者
Boitelle, P. [1 ,4 ]
Tapie, L. [2 ,4 ]
Mawussi, B. [2 ,4 ]
Fromentin, O. [3 ,4 ]
机构
[1] Lille Nord France Univ, Fac Dent Surg, Dept Prosthodont, Cayenne, French Guiana
[2] Univ Paris 13, Sorbonne Paris Cite Univ Consortium, Fac Mech Engn, F-93430 Villetaneuse, France
[3] Paris Diderot Univ, Sorbonne Paris Cite, Hosp Rothschild, AP HP,Prosthodont Dept,Fac Dent Surg, Paris, France
[4] Paris Diderot Univ, Fac Dent Surg, Dent Mat URB2i, Paris, France
关键词
3D accuracy of evaluation; accuracy of fit; CAD/CAM; dental prostheses; design parameters; FIXED PARTIAL DENTURES; ZIRCONIA CROWN COPINGS; ALL-CERAMIC CROWNS; SINGLE-TOOTH RESTORATIONS; MARGINAL FIT; INTERNAL FIT; DENTAL PROSTHESES; IN-VITRO; LUTING AGENTS; MANUFACTURING PROCESSES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The accuracy of computer-aided design/computer-aided manufacturing (CAD/CAM) systems is linked to their technical characteristics and reliability for manufacturing the restoration designed. The aim of this study was to compare the accuracy of fit of zirconia copings manufactured with different CAD/CAM systems and their capacity to conform to pre-established spacer design settings. Methods: Sixty zirconia copings were manufactured by three CAD/CAM systems, with their spacers set as recommended by their manufacturer on occlusal, axial, and marginal surfaces. The 3D triple-scan optical technique was used to obtain a fit mapping and to analyze the marginal and axial accuracy of fit. The reliability of the 3D measurement method was estimated using intraclass correlation and repeatability coefficients. The preparation coping interface width results were statistically analyzed using non-parametric analysis (Kruskal-Wallis, one-way ANOVA, and Wilcoxon signed rank tests) (P < 0.05). Results: The repeatability coefficient was 6, 8, and 15 mu m for axial, marginal, and occlusal interface width measurements, respectively. For the three systems tested, no differences were found in the marginal area of the copings studied, with a mean fitting accuracy ranging from 54.3 to 66.6 mu m interface width. Statistically significant differences between groups were observed for the fitting accuracy measured in axial and occlusal areas. With the spacers set in the different areas, mean fit measurements of the zirconia copings were significantly larger, with an increased fit width ranging from 30 to 73 mu m. Significance: The three CAD/CAM systems evaluated allowed similar marginal accuracy but failed to reproduce the pre-established spacer parameters, with larger spacing showing throughout.
引用
收藏
页码:27 / 43
页数:17
相关论文
共 50 条
  • [42] Comparison of the accuracy of impressions made of 2 implants with interfering axial convergence with CAD-CAM impression copings and the altered cast technique: An in vitro study
    Sadegholvad, Maryam
    Ansarifard, Elham
    Derafshi, Reza
    Dehno, Seyede Mina Salehi
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 745.e1 - 745.e7
  • [43] The current status on 3D scanning and CAD/CAM applications in textile research
    Spelic, Ivana
    INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2020, 32 (06) : 891 - 907
  • [44] 3D virtual planning and cad/cam technology applied to orthognathic surgery
    Scherzberg, Jessica
    Lucas, Antonio Bettencourt
    Queiroga, Joana
    Guimaraes, Adriana
    Malo, Luisa
    do Vale, Francisco
    ANNALS OF MEDICINE, 2018, 50 : S109 - S109
  • [45] Evaluation on the Plate Laminated Method using 3D CAD/CAM/CAE system for Construction of Canoe Hull
    Jeong, Jae-Hyun
    Kim, Heui-Jung
    Lee, Sung-Yul
    Park, Dong-Hyun
    Won, Jong-Pil
    Moon, Kyung-Man
    CURRENT TRENDS IN THE DEVELOPMENT OF INDUSTRY, PTS 1 AND 2, 2013, 785-786 : 1556 - +
  • [46] 3D打印在CAD/CAM教学中的应用
    王海峰
    姜鹏飞
    教育现代化, 2018, 5 (24) : 194 - 196
  • [47] MANUFACTURE OF INJECTION-LAMINATION MOLDS USING 3D CAD CAM
    SENDLER, U
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1991, 99 (03): : CA32 - CA33
  • [48] Accuracy in breast shape alignment with 3D surface fitting algorithms
    Riboldi, Marco
    Gierga, David P.
    Chen, George T. Y.
    Baroni, Guido
    MEDICAL PHYSICS, 2009, 36 (04) : 1193 - 1198
  • [49] CAD/CAM/CAE representation of 3D objects measured by fringe projection
    Pancewicz, T
    Kujawinska, MG
    LASER INTERFEROMETRY IX: APPLICATIONS, 1998, 3479 : 70 - 75
  • [50] Trueness and fitting accuracy of maxillary 3D printed complete dentures
    Yoshidome, Kazuki
    Torii, Mana
    Kawamura, Noboru
    Shimpo, Hidemasa
    Ohkubo, Chikahiro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 559 - 564