3D fitting accuracy evaluation of CAD/CAM copings - comparison with spacer design settings

被引:0
|
作者
Boitelle, P. [1 ,4 ]
Tapie, L. [2 ,4 ]
Mawussi, B. [2 ,4 ]
Fromentin, O. [3 ,4 ]
机构
[1] Lille Nord France Univ, Fac Dent Surg, Dept Prosthodont, Cayenne, French Guiana
[2] Univ Paris 13, Sorbonne Paris Cite Univ Consortium, Fac Mech Engn, F-93430 Villetaneuse, France
[3] Paris Diderot Univ, Sorbonne Paris Cite, Hosp Rothschild, AP HP,Prosthodont Dept,Fac Dent Surg, Paris, France
[4] Paris Diderot Univ, Fac Dent Surg, Dent Mat URB2i, Paris, France
关键词
3D accuracy of evaluation; accuracy of fit; CAD/CAM; dental prostheses; design parameters; FIXED PARTIAL DENTURES; ZIRCONIA CROWN COPINGS; ALL-CERAMIC CROWNS; SINGLE-TOOTH RESTORATIONS; MARGINAL FIT; INTERNAL FIT; DENTAL PROSTHESES; IN-VITRO; LUTING AGENTS; MANUFACTURING PROCESSES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The accuracy of computer-aided design/computer-aided manufacturing (CAD/CAM) systems is linked to their technical characteristics and reliability for manufacturing the restoration designed. The aim of this study was to compare the accuracy of fit of zirconia copings manufactured with different CAD/CAM systems and their capacity to conform to pre-established spacer design settings. Methods: Sixty zirconia copings were manufactured by three CAD/CAM systems, with their spacers set as recommended by their manufacturer on occlusal, axial, and marginal surfaces. The 3D triple-scan optical technique was used to obtain a fit mapping and to analyze the marginal and axial accuracy of fit. The reliability of the 3D measurement method was estimated using intraclass correlation and repeatability coefficients. The preparation coping interface width results were statistically analyzed using non-parametric analysis (Kruskal-Wallis, one-way ANOVA, and Wilcoxon signed rank tests) (P < 0.05). Results: The repeatability coefficient was 6, 8, and 15 mu m for axial, marginal, and occlusal interface width measurements, respectively. For the three systems tested, no differences were found in the marginal area of the copings studied, with a mean fitting accuracy ranging from 54.3 to 66.6 mu m interface width. Statistically significant differences between groups were observed for the fitting accuracy measured in axial and occlusal areas. With the spacers set in the different areas, mean fit measurements of the zirconia copings were significantly larger, with an increased fit width ranging from 30 to 73 mu m. Significance: The three CAD/CAM systems evaluated allowed similar marginal accuracy but failed to reproduce the pre-established spacer parameters, with larger spacing showing throughout.
引用
收藏
页码:27 / 43
页数:17
相关论文
共 50 条
  • [31] Comparative Analysis between Conventional Acrylic, CAD/CAM Milled, and 3D CAD/CAM Printed Occlusal Splints
    Abad-Coronel, Cristian
    Ruano Espinosa, Carolina
    Ordonez Palacios, Sofia
    Paltan, Cesar A.
    Fajardo, Jorge I.
    MATERIALS, 2023, 16 (18)
  • [32] A review on clinical use of CAD/CAM and 3D printed dentures
    Alhallak, Khaled
    Hagi-Pavli, Eleni
    Nankali, Ali
    BRITISH DENTAL JOURNAL, 2023,
  • [33] CAD/CAM design and 3D printing of a personalised rapid palatal expander for maxillary transverse deficiency
    Wang, Chunlin
    Xiang, Xiaosong
    Mao, Qin
    Liu, Conghua
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2024, 74 (01) : 153 - 157
  • [34] MODERN DENTAL CAD/CAM SYSTEMS WITH INTRAORAL 3D PROFILOMETERS
    Levin, G. G.
    Vishnyakov, G. N.
    Loshchilov, K. E.
    Ibragimov, T. I.
    Lebedenko, I. Yu.
    Tsalikova, N. A.
    MEASUREMENT TECHNIQUES, 2010, 53 (03) : 321 - 324
  • [35] Modern dental CAD/CAM systems with intraoral 3D profilometers
    G. G. Levin
    G. N. Vishnyakov
    K. E. Loshchilov
    T. I. Ibragimov
    I. Yu. Lebedenko
    N. A. Tsalikova
    Measurement Techniques, 2010, 53 : 321 - 324
  • [36] Mathematical modelling of 3D woven fabrics for CAD/CAM software
    Chen, Xiaogang
    TEXTILE RESEARCH JOURNAL, 2011, 81 (01) : 42 - 50
  • [37] 3D Specific Systems: Design and CAD
    Franzon, Paul D.
    Davis, W. Rhett
    Thorolfsson, Thor
    Melamed, Samson
    2011 20TH ASIAN TEST SYMPOSIUM (ATS), 2011, : 470 - 473
  • [38] Evaluation of digital construction, production and intraoral position accuracy of novel 3D CAD/CAM titanium retainers; [Bewertung der digitalen Konstruktion, Herstellung und intraoralen Positionsgenauigkeit von neuartigen 3‑D CAD/CAM-Titan-Retainern]
    Koller S.
    Craveiro R.B.
    Niederau C.
    Pollak T.L.
    Knaup I.
    Wolf M.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2023, 84 (6): : 384 - 391
  • [39] Design and CAD for 3D integrated circuits
    Franzon, Paul D.
    Davis, W. Rhett
    Steer, Michael B.
    Lipa, Steve
    Oh, Eun Chu
    Thorolfsson, Thor
    Melamed, Samson
    Luniya, Sonali
    Doxsee, Tad
    Berkeley, Stephen
    Shani, Ben
    Obermiller, Kurt
    2008 45TH ACM/IEEE DESIGN AUTOMATION CONFERENCE, VOLS 1 AND 2, 2008, : 668 - +
  • [40] Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system
    Lee, Wan-Sun
    Lee, Du-Hyeong
    Lee, Kyu-Bok
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04): : 265 - 270