Reduced field of view echo-planar imaging diffusion tensor MRI for pediatric spinal tumors

被引:5
|
作者
Kim, Lily H. [1 ]
Lee, Edward H. [3 ]
Galvez, Michelle [2 ]
Aksoy, Murat [2 ]
Skare, Stefan [4 ]
O'Halloran, Rafael [5 ]
Edwards, Michael S. B. [1 ]
Holdsworth, Samantha J. [6 ,7 ]
Yeom, Kristen W. [2 ]
机构
[1] Stanford Univ, Sch Med, Dept Neurosurg, Stanford, CA USA
[2] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA USA
[3] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[4] Karolinska Inst, Clin Neurosci, Stockholm, Sweden
[5] Hyperfine Res Inc, Guilford, CT USA
[6] Univ Auckland, Fac Med & Hlth Sci, Dept Anat & Med Imaging, Auckland, New Zealand
[7] Univ Auckland, Fac Med & Hlth Sci, Ctr Brain Res, Auckland, New Zealand
基金
瑞典研究理事会;
关键词
diffusion tensor imaging; central nervous system tumors; echo-planar imaging; spine imaging; pediatric neurosurgery; ZOOM-EPI; diffusion MRI; oncology; HUMAN OPTIC-NERVE; CORD TUMORS; OBLIQUE MULTISLICE; WEIGHTED MR; TRACTOGRAPHY; DTI; RESOLUTION; EPI; RESECTABILITY; EPIDEMIOLOGY;
D O I
10.3171/2019.4.SPINE19178
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Spine MRI is a diagnostic modality for evaluating pediatric CNS tumors. Applying diffusion-weighted MRI (DWI) or diffusion tensor imaging (DTI) to the spine poses challenges due to intrinsic spinal anatomy that exacerbates various image-related artifacts, such as signal dropouts or pileups, geometrical distortions, and incomplete fat suppression. The zonal oblique multislice (ZOOM)-echo-planar imaging (EPI) technique reduces geometric distortion and image blurring by reducing the field of view (FOV) without signal aliasing into the FOV. The authors hypothesized that the ZOOM-EPI method for spine DTI in concert with conventional spinal MRI is an efficient method for augmenting the evaluation of pediatric spinal tumors. METHODS Thirty-eight consecutive patients (mean age 8 years) who underwent ZOOM-EPI spine DTI for CNS tumor workup were retrospectively identified. Patients underwent conventional spine MRI and ZOOM-EPI DTI spine MRI. Two blinded radiologists independently reviewed two sets of randomized images: conventional spine MRI without ZOOM-EPI DTI, and conventional spine MRI with ZOOM-EPI DTI. For both image sets, the reviewers scored the findings based on lesion conspicuity and diagnostic confidence using a 5-point Likert scale. The reviewers also recorded presence of tumors. Quantitative apparent diffusion coefficient (ADC) measurements of various spinal tumors were extracted. Tractography was performed in a subset of patients undergoing presurgical evaluation. RESULTS Sixteen patients demonstrated spinal tumor lesions. The readers were in moderate agreement (kappa = 0.61, 95% CI 0.30-0.91). The mean scores for conventional MRI and combined conventional MRI and DTI were as follows, respectively: 3.0 and 4.0 for lesion conspicuity (p = 0.0039), and 2.8 and 3.9 for diagnostic confidence (p < 0.001). ZOOM-EPI DTI identified new lesions in 3 patients. In 3 patients, tractography used for neurosurgical planning showed characteristic fiber tract projections. The mean weighted ADCs of low- and high-grade tumors were 1201 x 10(-6) and 865 x 10-6 mm(2)/sec (p = 0.002), respectively; the mean minimum weighted ADCs were 823 x 10(-6) and 474 x 10(-6) mm(2)/sec (p = 0.0003), respectively. CONCLUSIONS Diffusion MRI with ZOOM-EPI can improve the detection of spinal lesions while providing quantitative diffusion information that helps distinguish low-from high-grade tumors. By adding a 2-minute DTI scan, quantitative diffusion information and tract profiles can reliably be obtained and serve as a useful adjunct to presurgical planning for pediatric spinal tumors.
引用
收藏
页码:607 / 615
页数:9
相关论文
共 50 条
  • [1] Diffusion Tensor Imaging of the Normal Pediatric Spinal Cord Using an Inner Field of View Echo-Planar Imaging Sequence
    Barakat, N.
    Mohamed, F. B.
    Hunter, L. N.
    Shah, P.
    Faro, S. H.
    Samdani, A. F.
    Finsterbusch, J.
    Betz, R.
    Gaughan, J.
    Mulcahey, M. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1127 - 1133
  • [2] The b matrix in diffusion tensor echo-planar imaging
    Mattiello, J
    Basser, PJ
    LeBihan, D
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 292 - 300
  • [3] Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging
    Zaharchuk, G.
    Saritas, E. U.
    Andre, J. B.
    Chin, C. T.
    Rosenberg, J.
    Brosnan, T. J.
    Shankaranarayan, A.
    Nishimura, D. G.
    Fischbein, N. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (05) : 813 - 820
  • [4] High resolution diffusion tensor imaging using interleaved echo-planar imaging
    Bammer, R
    Augustin, M
    Seifert, T
    Strasser-Fuchs, S
    Stollberger, R
    Wach, P
    Hartung, HP
    Fazekas, F
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 2 - 11
  • [5] Modified Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate: Comparison With Reduced Field-of-View Imaging and Single Shot Echo-Planar Imaging
    Lee, Eun Ji
    Hwang, Jiyoung
    Chang, Yun-Woo
    Hong, Seong Sook
    Oh, Eunsun
    Nam, Bo Da
    Sung, Jae Kon
    Thomas, Benkert
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 367 - 373
  • [6] ECHO-PLANAR IMAGING OF DIFFUSION AND PERFUSION
    TURNER, R
    LEBIHAN, D
    CHESNICK, AS
    MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 247 - 253
  • [7] ECHO-PLANAR DIFFUSION SPECTROSCOPIC IMAGING
    BITO, Y
    HIRATA, S
    NABESHIMA, T
    YAMAMOTO, E
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 69 - 73
  • [8] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462
  • [9] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [10] π Echo-Planar Imaging with concomitant field compensation for porous media MRI
    Xiao, Dan
    Balcom, Bruce J.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 260 : 38 - 45