Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging

被引:87
|
作者
Zaharchuk, G. [1 ]
Saritas, E. U. [2 ]
Andre, J. B.
Chin, C. T. [3 ]
Rosenberg, J.
Brosnan, T. J.
Shankaranarayan, A. [4 ]
Nishimura, D. G. [2 ]
Fischbein, N. J.
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA USA
[4] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
WEIGHTED MRI; MULTIPLE-SCLEROSIS; IN-VIVO; CERVICAL CORD; OPTIC-NERVE; TENSOR MRI; RESOLUTION; INFARCTION; EPI; TRACTOGRAPHY;
D O I
10.3174/ajnr.A2418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fF0V SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fF0V SS-EPI DWI normalized for either image readout time (low-resolution fF0V) or spatial resolution (high-resolution fF0V). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity-to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fF0V sequences were not statistically different (rFOV: 1.01 +/- 0.18 x 10(-3) mm(2)/s; low-resolution fFOV: 1.12 +/- 0.22 X 10(-3) mm(2)/s; high-resolution fFOV: 1.10 +/- 0.21 x 10(-3) mm(2)/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fF0V SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fF0V methods.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [1] Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging
    Kim, Hyungjin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Jang, Jin-Young
    Kim, Sun-Whe
    Ryu, Ji Kon
    Kannengiesser, Stephan
    Ha, Joon Koo
    Choi, Byung Ihn
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1216 - 1225
  • [2] Modified Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate: Comparison With Reduced Field-of-View Imaging and Single Shot Echo-Planar Imaging
    Lee, Eun Ji
    Hwang, Jiyoung
    Chang, Yun-Woo
    Hong, Seong Sook
    Oh, Eunsun
    Nam, Bo Da
    Sung, Jae Kon
    Thomas, Benkert
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 367 - 373
  • [3] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [4] Evaluation of diffusion-weighted magnetic resonance imaging of the rectal cancers: comparison between modified reduced field-of-view single-shot echo-planar imaging with tilted two-dimensional radiofrequency excitation pulses and conventional full field-of-view readout-segmented echo-planar imaging
    Inoue, Atsuo
    Tanabe, Masahiro
    Ihara, Kenichiro
    Hideura, Keiko
    Higashi, Mayumi
    Benkert, Thomas
    Imai, Hiroshi
    Yamane, Masatoshi
    Yamaguchi, Takahiro
    Ueda, Takaaki
    Ito, Katsuyoshi
    RADIOLOGIA MEDICA, 2023, 128 (10): : 1192 - 1198
  • [5] Evaluation of diffusion-weighted magnetic resonance imaging of the rectal cancers: comparison between modified reduced field-of-view single-shot echo-planar imaging with tilted two-dimensional radiofrequency excitation pulses and conventional full field-of-view readout-segmented echo-planar imaging
    Atsuo Inoue
    Masahiro Tanabe
    Kenichiro Ihara
    Keiko Hideura
    Mayumi Higashi
    Thomas Benkert
    Hiroshi Imai
    Masatoshi Yamane
    Takahiro Yamaguchi
    Takaaki Ueda
    Katsuyoshi Ito
    La radiologia medica, 2023, 128 : 1192 - 1198
  • [6] Comparison of single-shot and multishot echo-planar imaging and conventional SE MR imaging of the brain
    Bradley, WG
    Chen, D
    Douglas, MR
    Ramirez, GF
    Slocum, GR
    Vu, BT
    RADIOLOGY, 1996, 201 : 982 - 982
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [8] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [9] Diffusion Tensor Imaging of the Brachial Plexus: A Comparison between Readout-segmented and Conventional Single-shot Echo-planar Imaging
    Ho, Michael J.
    Ciritsis, Alexander
    Manoliu, Andrei
    Stieltjes, Bram
    Marcon, Magda
    Andreisek, Gustav
    Kuhn, Felix Pierre
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 150 - 157
  • [10] High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T
    Ma, Chao
    Li, Yan-jun
    Pan, Chun-shu
    Wang, He
    Wang, Jian
    Chen, Shi-yue
    Lu, Jian-ping
    MAGNETIC RESONANCE IMAGING, 2014, 32 (02) : 125 - 131