ECHO-PLANAR IMAGING OF DIFFUSION AND PERFUSION

被引:114
|
作者
TURNER, R
LEBIHAN, D
CHESNICK, AS
机构
[1] NIH,WARREN G MAGNUSON CLIN CTR,DEPT DIAGNOST RADIOL,BETHESDA,MD 20892
[2] NHLBI,BETHESDA,MD 20892
关键词
D O I
10.1002/mrm.1910190210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Use of the Stejskal‐Tanner sequence for performing diffusion images in the human brain tends to be complicated by the presence of artifacts caused by voluntary or involuntary, sometimes pulsatile, motion. We describe the implementation of the technique of echo‐planar diffusion imaging, which avoids these artifacts and allows reproducible quantitative values of the diffusion coefficient to be measured in vivo. The effects of perfusion are easily visible in a phantom containing a gel. The results for human brain show a significant “perfusion fraction” in grey matter, consistent with an extracellular, possibly microvascular, volume of about 10%. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:247 / 253
页数:7
相关论文
共 50 条
  • [1] ECHO-PLANAR DIFFUSION SPECTROSCOPIC IMAGING
    BITO, Y
    HIRATA, S
    NABESHIMA, T
    YAMAMOTO, E
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 69 - 73
  • [2] ECHO-PLANAR DIFFUSION AND PERFUSION IMAGING OF ISCHEMIA IN PATIENTS WITH AND WITHOUT SIGNIFICANT CAROTID DISEASE
    YUH, WT
    SIMONSON, TM
    CROSBY, DL
    MAGNOTTA, VA
    MAEDA, M
    EHRHARDT, JC
    RADIOLOGY, 1995, 197 : 305 - 305
  • [3] Moyamoya disease: Evaluation with diffusion-weighted and perfusion echo-planar MR imaging
    Yamada, I
    Himeno, Y
    Nagaoka, I
    Akimoto, H
    Matsushima, Y
    Kuroiwa, T
    Shibuya, H
    RADIOLOGY, 1999, 212 (02) : 340 - 347
  • [4] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [5] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    eMagRes, 2007,
  • [6] The b matrix in diffusion tensor echo-planar imaging
    Mattiello, J
    Basser, PJ
    LeBihan, D
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 292 - 300
  • [7] MULTISLICE PERFUSION AND DIFFUSION IMAGING OF ACUTE HUMAN STROKE WITH ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING
    WARACH, S
    WIELOPOLSKI, P
    EDELMAN, RR
    ANNALS OF NEUROLOGY, 1993, 34 (02) : 287 - 287
  • [8] Normal myocardial perfusion assessed with multishot echo-planar imaging
    Schwitter, J
    Debatin, JF
    vonSchulthess, GK
    McKinnon, GC
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 140 - 147
  • [9] ECHO-PLANAR IMAGING OF PERFLUOROCARBONS
    BARKER, BR
    MASON, RP
    PESHOCK, RM
    MAGNETIC RESONANCE IMAGING, 1993, 11 (08) : 1165 - 1173
  • [10] ADVANCES IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    DOYLE, M
    CHAPMAN, B
    GUILFOYLE, D
    CAWLEY, M
    COUPLAND, RE
    CHRISPIN, A
    SMALL, P
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 583 - 584