Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine

被引:0
|
作者
Ebmeier, K [1 ]
Giest, K [1 ]
Kalff, R [1 ]
机构
[1] Univ Hosp, Dept Neurol Surg, D-07740 Jena, Germany
关键词
spinal navigation; pedicle screws; intraoperative imaging; thoracic spine;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We report on our experiences with the use of intraoperative CT imaging in surgery of the thoracic spine and on our results of pedicle screw insertion using spinal navigation and implantable fiducial markers. For our operations we used the Tomoscan M-EG and the EasyGuideSpine (Philips Medical Systems). During the operation the patient was positioned on the mobile CT table. Following dorsal preparation, small titanium screws were implanted in the vertebrae so as to serve as fiducial markers. Image data were obtained by performing a spiral CT scan. Ventilation was suspended for the duration of the CT scan. Screw insertion as well as vertebral biopsies were performed using spinal navigation. Intraoperative CT scans were obtained to confirm the position of the implants and to assess the amount of bony decompression as well as the realignment. Since 1998, 112 patients with various disorders of the thoracic spine have been operated on using the described technique. 365 screws were inserted in the area of T1 to T12. There were 23 (6.3%) misplacements of pedicle screws. In 42 cases (11.5%) we observed a minimal lateral perforation (< 2 mm) of the pedicle wall. No neurological, cardiovascular, or pulmonary injury occurred. Intraoperative CT imaging influenced surgical decisions as well as the final result of surgery. Despite the use of intraoperative imaging and accurate spinal navigation, pedicle screw placement in the thoracic spine remains extremely challenging.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 50 条
  • [31] A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    Chen, Hsuan-Yu
    Xiao, Xiu-Yun
    Chen, Chih-Wei
    Chou, Hao-Kai
    Sung, Chen-Yu
    Lin, Feng Huei
    Chen, Po-Quang
    Wong, Tze-hong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [32] Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
    Mac-Thiong, JM
    Labelle, H
    Rooze, M
    Feipel, V
    Aubin, CE
    EUROPEAN SPINE JOURNAL, 2003, 12 (05) : 542 - 547
  • [33] Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
    Jean-Marc Mac-Thiong
    Hubert Labelle
    Marcel Rooze
    Véronique Feipel
    Carl-Eric Aubin
    European Spine Journal, 2003, 12 : 542 - 547
  • [34] Pedicle guide for thoracic pedicle screw placement
    Abode-Iyamah, Kingsley
    Stemper, Luke
    Rachman, Shane
    Schneider, Kelly
    Sick, Kathryn
    Hitchon, Patrick
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 10 (03) : 211 - 220
  • [35] Comparison of the Accuracy and Safety of Pedicle Screw Placement in Thoracic Spine Between 3D Printed Navigation Templates and Free Hand Technique
    Kovalenko, R. A.
    Ptashnikov, D. A.
    Cherebillo, V. Yu
    Kashin, V. A.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2020, 26 (03): : 49 - 60
  • [36] Postoperative Computed Tomography Assessment of Pedicle Screw Placement Accuracy
    Lotfinia, Iraj
    Sayyahmelli, Sima
    Gavami, Mostafa
    TURKISH NEUROSURGERY, 2010, 20 (04) : 500 - 507
  • [37] Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine
    Rajan, Vinod V.
    Kamath, Vijay
    Shetty, Ajoy Prasad
    Rajasekaran, S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2010, 44 (02) : 163 - 168
  • [38] Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine
    Vinod V. Rajan
    Vijay Kamath
    Ajoy Prasad Shetty
    S. Rajasekaran
    Indian Journal of Orthopaedics, 2010, 44 : 163 - 168
  • [39] Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques
    Wu Han
    Gao Zhong-li
    Wang Jin-cheng
    Li Ying-pu
    Xia Peng
    Jiang Rui
    CHINESE JOURNAL OF TRAUMATOLOGY, 2010, 13 (04) : 201 - 205
  • [40] Accuracy of computed tomography in assessing thoracic pedicle screw malposition
    Fayyazi, AH
    Hugate, RR
    Pennypacker, J
    Gelb, DE
    Ludwig, SC
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (05): : 367 - 371