Accuracy of computed tomography in assessing thoracic pedicle screw malposition

被引:26
|
作者
Fayyazi, AH
Hugate, RR
Pennypacker, J
Gelb, DE
Ludwig, SC
机构
[1] Univ Maryland, Dept Orthopaed, Baltimore, MD 21201 USA
[2] SUNY Upstate Med Univ, Inst Spine Care, Dept Orthoped Surg, Syracuse, NY USA
[3] Milton S Hershey Med Ctr, Dept Orthopaed & Rehabil, Hershey, PA USA
来源
关键词
thoracic spine; pedicle screw; computed tomography; reliability; accuracy;
D O I
10.1097/01.bsd.0000112049.36255.bc
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Transpedicular instrumentation of the thoracic spine is potentially dangerous because of the close proximity of vital structures and the morphologic variability seen. Computed tomography has become the gold standard in evaluating the position of thoracic pedicle screws in vivo. Unfortunately, despite its common use, the accuracy of computed tomography has not been adequately investigated. The objective of this work was to evaluate the accuracy of computed tomography in evaluating the position of thoracic pedicle screws. Methods: One hundred ninety-four thoracic pedicles in nine cadaveric specimens were instrumented and evaluated postoperatively with computed tomography and open dissection. Computed tomography films were assessed by three blinded observers who noted the position of each pedicle screw on two separate occasions. These data were subsequently compared with the open dissection data. Results: Computed tomography was found to be 76 +/- 16% sensitive and 75 +/- 13% specific when compared with open dissection. Overall accuracy was 76 +/- 8%. Intraobserver accuracy was 79 +/- 5% in assessing thoracic pedicle screws by computed tomography. Fair to moderate degree of agreement was demonstrated for both interobserver and intraobserver data using kappa values. Conclusions: Computed tomography was found to be relatively insensitive in assessing thoracic pedicle screw position. In the face of postoperative complications, surgical exploration and hardware removal may still be necessary despite negative computed tomography.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [1] The accuracy of computed tomography in assessing cervical pedicle screw placement
    Kim, HS
    Heller, JG
    Hudgins, PA
    Fountain, JA
    SPINE, 2003, 28 (21) : 2441 - 2446
  • [2] Postoperative Computed Tomography Assessment of Pedicle Screw Placement Accuracy
    Lotfinia, Iraj
    Sayyahmelli, Sima
    Gavami, Mostafa
    TURKISH NEUROSURGERY, 2010, 20 (04) : 500 - 507
  • [3] Pediatric pedicle screw (In) accuracy based on postoperative computed tomography
    Sahni, Deshdeepak
    Prasad, Prashant
    Hadley, Caroline
    Tran, Brandon H.
    Fulkerson, Daniel H.
    Hwang, Steven W.
    Jea, Andrew
    JOURNAL OF PEDIATRIC NEURORADIOLOGY, 2014, 3 (04) : 161 - 169
  • [4] Accuracy of pedicle screw placement in scoliosis surgery by means of computed tomography
    Halm, H
    Liljenqvist, U
    Link, T
    Jerosch, J
    Winkelmann, W
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1996, 134 (06): : 492 - 497
  • [5] Assessment of pedicle screw malposition rates in thoracolumbosacral spine: results of postoperative computed tomography in 100 patients
    Aslanbas, Ozcan
    Oktay, Kadir
    Ozsoy, Kerem Mazhar
    Cetinalp, Nuri Eralp
    Tuna, Metin
    CUKUROVA MEDICAL JOURNAL, 2018, 43 (04): : 816 - 820
  • [6] Accuracy of pedicle screw placement using intraoperative neurophysiological monitoring and computed tomography
    Mavrogenis, Andreas F.
    Papagelopoulos, Panayiotis J.
    Korres, Demetrios S.
    Papadopoulos, Konstantinos
    Sakas, Damianos E.
    Pneumaticos, Spiros
    Journal of Long-Term Effects of Medical Implants, 2009, 19 (01) : 41 - 48
  • [7] Value of computed tomography Hounsfield units in predicting pedicle screw loosening in the thoracic spine
    Lee, Minsu
    Lee, Eugene
    Lee, Joon Woo
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [8] Inter- and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement
    Rao, G
    Brodke, DS
    Rondina, M
    Bacchus, K
    Dailey, AT
    SPINE, 2003, 28 (22) : 2527 - 2530
  • [9] Value of computed tomography Hounsfield units in predicting pedicle screw loosening in the thoracic spine
    Minsu Lee
    Eugene Lee
    Joon Woo Lee
    Scientific Reports, 12
  • [10] ACCURACY OF PEDICLE SCREW PLACEMENT IN LUMBAR FUSIONS BY PLAIN RADIOGRAPHS AND COMPUTED-TOMOGRAPHY
    FARBER, GL
    PLACE, HM
    MAZUR, RA
    JONES, DEC
    DAMIANO, TR