Accuracy of computed tomography in assessing thoracic pedicle screw malposition

被引:26
|
作者
Fayyazi, AH
Hugate, RR
Pennypacker, J
Gelb, DE
Ludwig, SC
机构
[1] Univ Maryland, Dept Orthopaed, Baltimore, MD 21201 USA
[2] SUNY Upstate Med Univ, Inst Spine Care, Dept Orthoped Surg, Syracuse, NY USA
[3] Milton S Hershey Med Ctr, Dept Orthopaed & Rehabil, Hershey, PA USA
来源
关键词
thoracic spine; pedicle screw; computed tomography; reliability; accuracy;
D O I
10.1097/01.bsd.0000112049.36255.bc
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Transpedicular instrumentation of the thoracic spine is potentially dangerous because of the close proximity of vital structures and the morphologic variability seen. Computed tomography has become the gold standard in evaluating the position of thoracic pedicle screws in vivo. Unfortunately, despite its common use, the accuracy of computed tomography has not been adequately investigated. The objective of this work was to evaluate the accuracy of computed tomography in evaluating the position of thoracic pedicle screws. Methods: One hundred ninety-four thoracic pedicles in nine cadaveric specimens were instrumented and evaluated postoperatively with computed tomography and open dissection. Computed tomography films were assessed by three blinded observers who noted the position of each pedicle screw on two separate occasions. These data were subsequently compared with the open dissection data. Results: Computed tomography was found to be 76 +/- 16% sensitive and 75 +/- 13% specific when compared with open dissection. Overall accuracy was 76 +/- 8%. Intraobserver accuracy was 79 +/- 5% in assessing thoracic pedicle screws by computed tomography. Fair to moderate degree of agreement was demonstrated for both interobserver and intraobserver data using kappa values. Conclusions: Computed tomography was found to be relatively insensitive in assessing thoracic pedicle screw position. In the face of postoperative complications, surgical exploration and hardware removal may still be necessary despite negative computed tomography.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [41] Pedicle Screw Pseudofracture on Computed Tomography Secondary to Metal Artifact Reduction
    Ge, Shuliang
    Kumar, Naresh
    Hallinan, James Thomas Patrick Decourcy
    DIAGNOSTICS, 2024, 14 (01)
  • [42] Observer reliability in evaluating pedicle screw placement using computed tomography
    Kosmopoulos, Victor
    Theumann, Nicolas
    Binaghi, Stefano
    Schizas, Constantin
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (04) : 531 - 536
  • [43] Observer reliability in evaluating pedicle screw placement using computed tomography
    Victor Kosmopoulos
    Nicolas Theumann
    Stefano Binaghi
    Constantin Schizas
    International Orthopaedics, 2007, 31 : 531 - 536
  • [44] Computed Tomography Based Anatomical Study to Assess Feasibility of Pedicle Screw Placement in the Lumbar and Lower Thoracic Pediatric Spine
    Shaikh, Kashif Ajaz
    Bennett, Garrett
    White, Ian Kainoa
    Bullis, Carli
    Fulkerson, Daniel H.
    NEUROSURGERY, 2012, 71 (02) : E567 - E567
  • [45] Usefulness of Electromyography Compared to Computed Tomography Scans in Pedicle Screw Placement
    Duffy, Michael F.
    Phillips, Jonathan H.
    Knapp, Dennis R.
    Herrera-Soto, Jose Antonio
    SPINE, 2010, 35 (02) : E43 - E48
  • [46] Pedicle screw insertion: computed tomography versus fluoroscopic image guidance
    Tsai-Sheng Fu
    Chak-Bor Wong
    Tsung-Ting Tsai
    Yen-Chiu Liang
    Lih-Huei Chen
    Wen-Jer Chen
    International Orthopaedics, 2008, 32 : 517 - 521
  • [47] Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle
    Sakamoto, T
    Neo, M
    Nakamura, T
    SPINE, 2004, 29 (22) : 2510 - 2514
  • [48] Triggered electromyographic threshold for accuracy of thoracic pedicle screw placement in a porcine model
    Lewis, SJ
    Lenke, LG
    Raynor, B
    Long, J
    Bridwell, KH
    Padberg, A
    SPINE, 2001, 26 (22) : 2485 - 2489
  • [49] Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: A proposed systematic approach to improve accuracy of interpretation
    Learch, TJ
    Massie, JB
    Pathria, MN
    Ahlgren, BA
    Garfin, SR
    SPINE, 2004, 29 (07) : 767 - 773
  • [50] Accuracy of Subaxial Cervical Pedicle Screw Placement Using Direct Visualization Versus Computed Tomography-Based Navigation
    Farber, S. Harrison
    Godzik, Jakub
    Hlubek, Randall J.
    Zhou, James J.
    Walker, Corey T.
    Kakarla, U. Kumar
    Uribe, Juan S.
    Turner, Jay D.
    CLINICAL SPINE SURGERY, 2022, 35 (01): : E104 - E110