摘要
Objective: Transpedicular instrumentation of the thoracic spine is potentially dangerous because of the close proximity of vital structures and the morphologic variability seen. Computed tomography has become the gold standard in evaluating the position of thoracic pedicle screws in vivo. Unfortunately, despite its common use, the accuracy of computed tomography has not been adequately investigated. The objective of this work was to evaluate the accuracy of computed tomography in evaluating the position of thoracic pedicle screws. Methods: One hundred ninety-four thoracic pedicles in nine cadaveric specimens were instrumented and evaluated postoperatively with computed tomography and open dissection. Computed tomography films were assessed by three blinded observers who noted the position of each pedicle screw on two separate occasions. These data were subsequently compared with the open dissection data. Results: Computed tomography was found to be 76 +/- 16% sensitive and 75 +/- 13% specific when compared with open dissection. Overall accuracy was 76 +/- 8%. Intraobserver accuracy was 79 +/- 5% in assessing thoracic pedicle screws by computed tomography. Fair to moderate degree of agreement was demonstrated for both interobserver and intraobserver data using kappa values. Conclusions: Computed tomography was found to be relatively insensitive in assessing thoracic pedicle screw position. In the face of postoperative complications, surgical exploration and hardware removal may still be necessary despite negative computed tomography.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [31] Pedicle screw malposition following spinal lumbar injury
    Akhaddar, Ali
    Atmane, El Mehdi
    PAN AFRICAN MEDICAL JOURNAL, 2014, 17
  • [32] Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement
    Rao, G
    Brodke, DS
    Rondina, M
    Dailey, AT
    JOURNAL OF NEUROSURGERY, 2002, 97 (02) : 223 - 226
  • [33] Accuracy of 837 pedicle screw positions in degenerative lumbar spine with conventional open surgery evaluated by computed tomography
    Ilkka Saarenpää
    Timo Laine
    Jussi Hirvonen
    Saija Hurme
    Esa Kotilainen
    Jaakko Rinne
    Katariina Korhonen
    Janek Frantzén
    Acta Neurochirurgica, 2017, 159 : 2011 - 2017
  • [34] Accuracy Assessment of Percutaneous Pedicle Screw Placement Using Cone Beam Computed Tomography with Metal Artifact Reduction
    Charles, Yann Philippe
    Al Ansari, Rawan
    Collinet, Arnaud
    De Marini, Pierre
    Schwartz, Jean
    Nachabe, Rami
    Schafer, Dirk
    Brendel, Bernhard
    Gangi, Afshin
    Cazzato, Roberto Luigi
    SENSORS, 2022, 22 (12)
  • [35] Accuracy of 837 pedicle screw positions in degenerative lumbar spine with conventional open surgery evaluated by computed tomography
    Saarenpaa, Ilkka
    Laine, Timo
    Hirvonen, Jussi
    Hurme, Saija
    Kotilainen, Esa
    Rinne, Jaakko
    Korhonen, Katariina
    Frantzen, Janek
    ACTA NEUROCHIRURGICA, 2017, 159 (10) : 2011 - 2017
  • [36] ACCURACY OF PEDICLE SCREW FIXATION IN LUMBAR SPINE BY FREE HAND TECHNIQUE STUDIED POST OPERATIVELY BY COMPUTED TOMOGRAPHY
    Kulkarni, R.
    Mesare, V.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2022, 34 (SUPPL 1) : S392 - S392
  • [37] Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations
    Yoshida, Go
    Sato, Koji
    Kanemura, Tokumi
    Iwase, Toshiki
    Togawa, Daisuke
    Matsuyama, Yukihiro
    ASIAN SPINE JOURNAL, 2016, 10 (04) : 630 - 638
  • [38] A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
    Tsai, Tai-Hsin
    Wu, Dong-Syuan
    Su, Yu-Feng
    Wu, Chieh-Hsin
    Lin, Chih-Lung
    MEDICINE, 2016, 95 (38)
  • [39] Computed Tomography-Based Prediction of Lumbar Pedicle Screw Loosening
    Shu, Li
    Wang, Xiaoyuan
    Li, Lei
    Aili, Abudunaibi
    Zhang, Rui
    Liu, Wenge
    Muheremu, Aikeremujiang
    BIOMED RESEARCH INTERNATIONAL, 2023, 2023
  • [40] Pedicle screw insertion: computed tomography versus fluoroscopic image guidance
    Fu, Tsai-Sheng
    Wong, Chak-Bor
    Tsai, Tsung-Ting
    Liang, Yen-Chiu
    Chen, Lih-Huei
    Chen, Wen-Jer
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (04) : 517 - 521