Stability of the xoft Axxent® X-ray source during simulated APBI

被引:0
|
作者
Burnside, R. [1 ]
La, Q. [1 ]
Mihaylov, J. [1 ]
Rusch, T. [1 ]
Axelrod, S. [1 ]
机构
[1] Xoft Inc, Fremont, CA USA
关键词
D O I
10.1118/1.2761108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the x‐ray output stability of the Xoft Axxent® Electronic Brachytherapy System while delivering fractionated doses to a phantom. Method and Materials: A balloon applicator was inflated in a 4.4 cm diameter spherical simulated lumpectomy cavity within an acrylic “breast” on a supine female full‐body phantom. Radiation treatments for 5 “patients” were delivered in 10 fractions BID for 5 days using one x‐ray source per patient. Per the usual procedure, the air kerma strength for each source was measured prior to each fraction with a calibrated well chamber then dose delivery time was automatically adjusted to account for this source strength. During each fraction, exposure rate was monitored using a calibrated Victoreen Model 451B ion chamber survey meter positioned approximately 10 cm below the phantom. Readings were downloaded at 1 second intervals to a spreadsheet. These data were then analyzed for stability and reproducibility. Results: Fifty fractions were delivered during the five days of simulated treatment. Average treatment time for each fraction was 11 minutes so each source had cumulative operating time of approximately 120 minutes including turn‐on and calibration time. Exposure rate measurements increased with decreased source‐to‐meter distance and with less intervening absorbing material. Exposure rates ranged from 0.1 to 0.55 R/h. The standard deviations from average exposure rates varied from 0.5% to 2.9% with an average over 50 fractions of 0.9%. Conclusions: The Axxent® Electronic Brachytherapy System performed well in five simulated APBI treatments. X‐ray source output and system stability were demonstrated to be within 3% for all treatment fractions. Research sponsored by Xoft, Inc. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2490 / 2490
页数:1
相关论文
共 50 条
  • [41] X-Ray Transmission of Vaginal Cylinders for Use with the Axxent r Electronic Brachytherapy System
    Hausen, H.
    Kelley, L.
    Lovoi, T.
    Mantese, L.
    Rusch, T.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2736 - +
  • [42] Characteristics of a molybdenum X-pinch X-ray source as a probe source for X-ray diffraction studies
    Zucchini, F.
    Bland, S. N.
    Chauvin, C.
    Combes, P.
    Sol, D.
    Loyen, A.
    Roques, B.
    Grunenwald, J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (03):
  • [43] X-ray high frequency pulse emission characteristic and application of CNT cold cathode x-ray source cathode x-ray source
    Lai, Sheng
    Tang, Xiaobin
    Liu, Yunpeng
    Mu, Junxu
    Feng, Zhaopeng
    Miao, Kai
    [J]. NANOTECHNOLOGY, 2022, 33 (07)
  • [44] A PLASMA X-RAY SOURCE FOR X-RAY-LITHOGRAPHY
    OKADA, I
    SAITOH, Y
    ITABASHI, S
    YOSHIHARA, H
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1986, 4 (01): : 243 - 247
  • [45] X pinch as a source for X-ray radiography
    Pikuz, SA
    Shelkovenko, TA
    Romanova, VM
    Sinars, DB
    Hammer, DA
    Bland, SN
    Lebedev, SV
    [J]. NUKLEONIKA, 2001, 46 (01) : 21 - 25
  • [46] X-ray imaging using a tunable coherent X-ray source based on parametric X-ray radiation
    Hayakawa, Y.
    Takahashi, Y.
    Kuwada, T.
    Sakae, T.
    Tanaka, T.
    Nakao, K.
    Nogami, K.
    Inagaki, M.
    Hayakawa, K.
    Sato, I.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8
  • [47] X-ray reflectivity imager with 15 W power X-ray source
    Jiang, Jinxing
    Sakurai, Kenji
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (09):
  • [48] Microfocus X-Ray Tubes with a Silicon Autoemission Nanocathode as an X-Ray Source
    Dyuzhev, N. A.
    Demin, G. D.
    Gryazneva, T. A.
    Pestov, A. E.
    Salashchenko, N. N.
    Chkhalo, N. I.
    Pudonin, F. A.
    [J]. BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2018, 45 (01) : 1 - 5
  • [49] Laboratory X-ray microscopy with a nano-focus X-ray source
    Nachtrab, Frank
    Ebensperger, Thomas
    Schummer, Bernhard
    Sukowski, Frank
    Hanke, Randolf
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6
  • [50] Development of an X-ray photoelectron microscopic system with a compact X-ray source
    Fujikawa, C
    Yamaguchi, N
    Ohchi, T
    Hara, T
    Watanabe, K
    Tanaka, I
    Taguchi, M
    [J]. LASER AND PARTICLE BEAMS, 2002, 20 (01) : 39 - 42