A New Valve-Less Trocar for Urologic Laparoscopy: Initial Evaluation

被引:32
|
作者
Herati, Amin S. [1 ]
Atalla, Mohamed A. [1 ]
Rais-Bahrami, Soroush [1 ]
Andonian, Sero [1 ]
Vira, Manish A. [1 ]
Kavoussi, Louis R. [1 ]
机构
[1] Hofstra Univ, Sch Med, N Shore LIJ Hlth Syst, Smith Inst Urol, New Hyde Pk, NY 11040 USA
关键词
CARBON-DIOXIDE ABSORPTION; PNEUMOPERITONEUM; CHOLECYSTECTOMY; RETROPERITONEAL; INSUFFLATION; SURGERY;
D O I
10.1089/end.2009.0376
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Laparoscopic trocars typically maintain pneumoperitoneum using trap door valves and silicone seals. However, valves and seals hinder passage of instruments, cause lens smudging, trap specimens and needles being removed from the abdominal cavity, and lose their seal with repeated instrument exchange. Aim: The aim of the present study was to evaluate the feasibility of a newly designed valve-less trocar. Methods: The valve-less trocar system creates a curtain of forced gas to maintain pneumoperitoneum. A separate unit filters smoke and recirculates captured escaping gas. The valve-less trocar was trialed in consecutive laparoscopic renal procedures of a single surgeon. Perioperative parameters and outcomes were collected and analyzed. The system's safety, advantages, and disadvantages were evaluated. Insufflation gas usage, elimination, and absorption were also measured. Results: Twenty-five patients underwent laparoscopic renal procedures using the valve-less trocar system. The procedures included laparoscopic partial, radical, and donor nephrectomy. The mean patient age was 58.26 years. The mean operative time was 125 minutes and the mean drop in Hb for the cohort was 2.34 g/dL (range 0.4-5.4). Two patients developed subcutaneous emphysema and of the two patients, one developed clinically insignificant pneumomediastinum postoperatively. There were no postoperative complications. The surgeon noted that the use of a valve-less trocar decreased smudging of laparoscopes, expeditiously evacuated smoke during cauterization leading to improved visualization, maintained pneumoperitoneum even while suctioning, and resulted in easy extraction of specimens and needles. It was noted that insufflation gas consumption was low and CO2 elimination was not impaired. Conclusion: Use of a valve-less trocar is safe. Decreased laparoscope smudging may translate into decreased operative times and reduced gas consumption may equate to cost savings. Additionally, its use brings several advantages and convenience to the operating surgeon. However, the system should be compared with conventional trocars prospectively to demonstrate clinical and economic benefit.
引用
收藏
页码:1535 / 1539
页数:5
相关论文
共 50 条
  • [41] The piezoelectric valve-less pump-improved dynamic model
    Ullmann, A
    Fono, I
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2002, 11 (06) : 655 - 664
  • [42] PUMP HEAD IMPROVEMENT OF DIFFUSER/NOZZLE VALVE-LESS MICROPUMP
    Tanaka, Seiichi
    Miyazaki, Koji
    Fujiwara, Seiji
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2013, 2013,
  • [43] New bi-directional valve-less silicon micro pump controlled by driving waveform
    Hayamizu, S
    Higashino, K
    Fujii, Y
    Sando, Y
    Yamamoto, K
    [J]. FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, : 113 - 116
  • [44] A new technique of primary trocar insertion for laparoscopy
    Kadar, N
    [J]. JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 1997, 4 (04): : 485 - 489
  • [45] A VALVE-LESS PLANAR FLUID PUMP WITH 2 PUMP CHAMBERS
    OLSSON, A
    STEMME, G
    STEMME, E
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1995, 47 (1-3) : 549 - 556
  • [46] A VALVE-LESS RECTIFICATION MINIPUMP BASED ON DYNAMIC RECTIFYING GEOMETRIES
    Fadl, Ahmed
    Demming, Stefanie
    Zhang, Zongqin
    Buettgenbach, Stephanus
    Krafczyk, Mannfred
    Meyer, Donna M. L.
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS, 2010, PTS A AND B, 2011, : 1151 - 1153
  • [47] An electrostatically driven valve-less peristaltic micropump with a stepwise chamber
    Lee, Ki Sung
    Kim, Bonghwan
    Shannon, Mark A.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2012, 187 : 183 - 189
  • [48] Valve-less piezoelectric pump with unsymmetrical slope chamber bottom
    Xia, Qi-Xiao
    Zhang, Jian-Hui
    Li, Hong
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2006, 14 (04): : 641 - 647
  • [49] Multi-physics coupling analysis and experiment of the valve-less micropump
    [J]. Guan, Y.-F. (sgyffg@126.com), 1600, Tsinghua University (30):
  • [50] Fabrication of components for a valve-less micropump or microejector by multilevel electroforming technology
    Chen, S. C.
    Cheng, C. H.
    Lin, Y. C.
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2007, 13 (5-6): : 455 - 463