A New Valve-Less Trocar for Urologic Laparoscopy: Initial Evaluation

被引:32
|
作者
Herati, Amin S. [1 ]
Atalla, Mohamed A. [1 ]
Rais-Bahrami, Soroush [1 ]
Andonian, Sero [1 ]
Vira, Manish A. [1 ]
Kavoussi, Louis R. [1 ]
机构
[1] Hofstra Univ, Sch Med, N Shore LIJ Hlth Syst, Smith Inst Urol, New Hyde Pk, NY 11040 USA
关键词
CARBON-DIOXIDE ABSORPTION; PNEUMOPERITONEUM; CHOLECYSTECTOMY; RETROPERITONEAL; INSUFFLATION; SURGERY;
D O I
10.1089/end.2009.0376
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Laparoscopic trocars typically maintain pneumoperitoneum using trap door valves and silicone seals. However, valves and seals hinder passage of instruments, cause lens smudging, trap specimens and needles being removed from the abdominal cavity, and lose their seal with repeated instrument exchange. Aim: The aim of the present study was to evaluate the feasibility of a newly designed valve-less trocar. Methods: The valve-less trocar system creates a curtain of forced gas to maintain pneumoperitoneum. A separate unit filters smoke and recirculates captured escaping gas. The valve-less trocar was trialed in consecutive laparoscopic renal procedures of a single surgeon. Perioperative parameters and outcomes were collected and analyzed. The system's safety, advantages, and disadvantages were evaluated. Insufflation gas usage, elimination, and absorption were also measured. Results: Twenty-five patients underwent laparoscopic renal procedures using the valve-less trocar system. The procedures included laparoscopic partial, radical, and donor nephrectomy. The mean patient age was 58.26 years. The mean operative time was 125 minutes and the mean drop in Hb for the cohort was 2.34 g/dL (range 0.4-5.4). Two patients developed subcutaneous emphysema and of the two patients, one developed clinically insignificant pneumomediastinum postoperatively. There were no postoperative complications. The surgeon noted that the use of a valve-less trocar decreased smudging of laparoscopes, expeditiously evacuated smoke during cauterization leading to improved visualization, maintained pneumoperitoneum even while suctioning, and resulted in easy extraction of specimens and needles. It was noted that insufflation gas consumption was low and CO2 elimination was not impaired. Conclusion: Use of a valve-less trocar is safe. Decreased laparoscope smudging may translate into decreased operative times and reduced gas consumption may equate to cost savings. Additionally, its use brings several advantages and convenience to the operating surgeon. However, the system should be compared with conventional trocars prospectively to demonstrate clinical and economic benefit.
引用
收藏
页码:1535 / 1539
页数:5
相关论文
共 50 条
  • [31] Characteristics of the diffuser/nozzle valve-less micro-pump
    Tanaka, Seiichi
    Tsukamoto, Hiroshi
    Miyazaki, Koji
    [J]. FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT AMSE/JSME FLUIDS ENGINEERING SUMMER CONFERENCE VOL 1, PTS A AND B, 2007, : 1135 - 1142
  • [32] EVALUATION OF THE DIRECT TROCAR INSERTION TECHNIQUE AT LAPAROSCOPY
    BYRON, JW
    FUJIYOSHI, CA
    MIYAZAWA, K
    [J]. OBSTETRICS AND GYNECOLOGY, 1989, 74 (03): : 423 - 425
  • [33] Dynamic analysis of a new micro-machined valve-less micro-injector
    Rahman, MA
    Zhao, Y
    Gong, TH
    [J]. MICROFLUIDIC DEVICES AND SYSTEMS II, 1999, 3877 : 54 - 65
  • [34] Valve-less diffuser micropumps fabricated using thermoplastic replication
    Olsson, A
    Larsson, O
    Holm, J
    Lundbladh, L
    Ohman, O
    Stemme, G
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1998, 64 (01) : 63 - 68
  • [35] Development of valve-less tube type micropump with PZT actuator
    Tsuchiya, Kazuyoshi
    Morishima, Akifumi
    Takamata, Atsushi
    Uetsuji, Yasutomo
    Nakamachi, Eiji
    [J]. BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING IV AND COMPLEX SYSTEMS, 2008, 7270
  • [36] Development of bi-directional valve-less micropump for liquid
    Matsumoto, S
    Klein, A
    Maeda, R
    [J]. MEMS '99: TWELFTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 1999, : 141 - 146
  • [37] A novel valve-less piezoelectric micropump generating recirculating flow
    Chen, Xiaosheng
    Chen, Zhenlin
    Gui, Zhenzhen
    Zhang, Fan
    Zhang, Weirong
    Zhou, Xiaosi
    Huang, Xi
    Zhang, Jianhui
    [J]. ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2021, 15 (01) : 1473 - 1490
  • [38] Diffuser-element design investigation for valve-less pumps
    Olsson, A
    Stemme, G
    Stemme, E
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1996, 57 (02) : 137 - 143
  • [39] Valve-less diffuser micropumps fabricated using thermoplastic replication
    Olsson, A
    Larsson, O
    Holm, J
    Lundbladh, L
    Ohman, O
    Stemme, G
    [J]. MEMS 97, PROCEEDINGS - IEEE THE TENTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND ROBOTS, 1997, : 305 - 310
  • [40] THE EFFECT OF MATERIAL PROPERTIES ON THE EFFICIENCY OF VALVE-LESS RECTIFICATION MICROPUMPS
    Fadl, Ahmed
    Demming, Stefanie
    Zhang, Zongqin
    Hoxhold, Bjoern
    Buettgenbach, Stephanus
    Krafczyk, Mannfred
    Meyer, Donna M. L.