A New Valve-Less Trocar for Urologic Laparoscopy: Initial Evaluation

被引:32
|
作者
Herati, Amin S. [1 ]
Atalla, Mohamed A. [1 ]
Rais-Bahrami, Soroush [1 ]
Andonian, Sero [1 ]
Vira, Manish A. [1 ]
Kavoussi, Louis R. [1 ]
机构
[1] Hofstra Univ, Sch Med, N Shore LIJ Hlth Syst, Smith Inst Urol, New Hyde Pk, NY 11040 USA
关键词
CARBON-DIOXIDE ABSORPTION; PNEUMOPERITONEUM; CHOLECYSTECTOMY; RETROPERITONEAL; INSUFFLATION; SURGERY;
D O I
10.1089/end.2009.0376
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Laparoscopic trocars typically maintain pneumoperitoneum using trap door valves and silicone seals. However, valves and seals hinder passage of instruments, cause lens smudging, trap specimens and needles being removed from the abdominal cavity, and lose their seal with repeated instrument exchange. Aim: The aim of the present study was to evaluate the feasibility of a newly designed valve-less trocar. Methods: The valve-less trocar system creates a curtain of forced gas to maintain pneumoperitoneum. A separate unit filters smoke and recirculates captured escaping gas. The valve-less trocar was trialed in consecutive laparoscopic renal procedures of a single surgeon. Perioperative parameters and outcomes were collected and analyzed. The system's safety, advantages, and disadvantages were evaluated. Insufflation gas usage, elimination, and absorption were also measured. Results: Twenty-five patients underwent laparoscopic renal procedures using the valve-less trocar system. The procedures included laparoscopic partial, radical, and donor nephrectomy. The mean patient age was 58.26 years. The mean operative time was 125 minutes and the mean drop in Hb for the cohort was 2.34 g/dL (range 0.4-5.4). Two patients developed subcutaneous emphysema and of the two patients, one developed clinically insignificant pneumomediastinum postoperatively. There were no postoperative complications. The surgeon noted that the use of a valve-less trocar decreased smudging of laparoscopes, expeditiously evacuated smoke during cauterization leading to improved visualization, maintained pneumoperitoneum even while suctioning, and resulted in easy extraction of specimens and needles. It was noted that insufflation gas consumption was low and CO2 elimination was not impaired. Conclusion: Use of a valve-less trocar is safe. Decreased laparoscope smudging may translate into decreased operative times and reduced gas consumption may equate to cost savings. Additionally, its use brings several advantages and convenience to the operating surgeon. However, the system should be compared with conventional trocars prospectively to demonstrate clinical and economic benefit.
引用
收藏
页码:1535 / 1539
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF A NEW VALVE-LESS TROCAR FOR UROLOGIC LAPAROSCOPY
    Atalla, M.
    Herati, A.
    Andonian, S.
    Rais-bahrami, S.
    Kavoussi, L.
    [J]. JOURNAL OF ENDOUROLOGY, 2009, 23 : A245 - A245
  • [2] VALVE-LESS TROCAR REDUCES CARBON DIOXIDE ABSORPTION DURING LAPAROSCOPY COMPARED TO CONVENTIONAL TROCARS
    Herati, A.
    Andonian, S.
    Rais-bahrami, S.
    Srinivasan, A. K.
    Richstone, L.
    Kavoussi, L. R.
    [J]. JOURNAL OF ENDOUROLOGY, 2009, 23 : A93 - A93
  • [3] The dynamic characteristics of a valve-less micropump
    Jiang, Dan
    Li, Song-Jing
    [J]. CHINESE PHYSICS B, 2012, 21 (07)
  • [4] The dynamic characteristics of a valve-less micropump
    蒋丹
    李松晶
    [J]. Chinese Physics B, 2012, 21 (07) : 363 - 371
  • [5] The impact of the AirSeal® valve-less trocar system in robotic colorectal surgery: a single-surgeon retrospective review
    Jessie Osborne Paull
    Salvatore A. Parsacandola
    Ada Graham
    Salini Hota
    Natalie Pudalov
    Vincent Obias
    [J]. Journal of Robotic Surgery, 2021, 15 : 87 - 92
  • [6] The first valve-less diffuser gas pump
    Olsson, A
    Stemme, G
    Stemme, E
    [J]. MEMS 97, PROCEEDINGS - IEEE THE TENTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND ROBOTS, 1997, : 108 - 113
  • [7] Principle and experimental verification of valve-less pump
    Zhao, Li-Qing
    Ji, Jing
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (12): : 2639 - 2649
  • [8] Piezoelectric analysis and testing of valve-less micropump
    [J]. Guan, Y.-F. (sgyffg@126.com), 2013, Shanghai Jiaotong University (47):
  • [9] Valve-less scroll compressor eliminates vibration
    不详
    [J]. HYDRAULICS & PNEUMATICS, 2000, 53 (04) : 10 - +
  • [10] The impact of the AirSeal(R) valve-less trocar system in robotic colorectal surgery: a single-surgeon retrospective review
    Paull, Jessie Osborne
    Parsacandola, Salvatore A.
    Graham, Ada
    Hota, Salini
    Pudalov, Natalie
    Obias, Vincent
    [J]. JOURNAL OF ROBOTIC SURGERY, 2021, 15 (01) : 87 - 92