Shear Wave Elastography and Shear Wave Dispersion Imaging in the Assessment of Liver Disease in Alpha1-Antitrypsin Deficiency

被引:3
|
作者
Schulz, Marten [1 ,2 ]
Kleinjans, Moritz [3 ,4 ,5 ]
Strnad, Pavel [3 ,4 ,5 ]
Demir, Muenevver [1 ,2 ]
Holtmann, Theresa M. [1 ,2 ]
Tacke, Frank [1 ,2 ]
Wree, Alexander [1 ,2 ]
机构
[1] Charite Univ Med Berlin, Dept Hepatol & Gastroenterol, Campus Virchow Klinikum CVK, D-13353 Berlin, Germany
[2] Charite Univ Med Berlin, Campus Charite Mitte CCM, D-13353 Berlin, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Gastroenterol Metab Dis & Intens Care, Med Clin 3, D-52074 Aachen, Germany
[4] European Reference Network ERN Rare Liver, Coordinating Ctr Alpha1 Antitrypsin Deficiency Re, D-52074 Aachen, Germany
[5] European Assoc Study Liver EASL, Registry Grp Alpha1 Liver, D-52074 Aachen, Germany
关键词
alpha1-antitrypsin deficiency (AATD); shear wave elastography (SWE); shear wave dispersion (SWD);
D O I
10.3390/diagnostics11040629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Liver affection of Alpha1-antitrypsin deficiency (AATD) can lead to cirrhosis and hepatocellular carcinoma (HCC). A noninvasive severity assessment of liver disease in AATD is urgently needed since laboratory parameters may not accurately reflect the extent of liver involvement. Preliminary data exist on two-dimensional shear wave elastography (2D-SWE) being a suitable method for liver fibrosis measurement in AATD. AATD patients without HCC were examined using 2D-SWE, shear wave dispersion imaging (SWD) and transient elastography (TE). Furthermore, liver steatosis was assessed using the controlled attenuation parameter (CAP) and compared to the new method of attenuation imaging (ATI). 29 AATD patients were enrolled, of which 18 had the PiZZ genotype, eight had PiMZ, two had PiSZ and one had a PiZP-Lowell genotype. 2D-SWE (median 1.42 m/S, range 1.14-1.83 m/S) and TE (median 4.8 kPa, range 2.8-24.6 kPa) values displayed a significant correlation (R = 0.475, p < 0.05). 2D-SWE, ATI (median 0.56 dB/cm/MHz, range 0.43-0.96 dB/cm/MHz) and CAP (median 249.5 dB/m, range 156-347 dB/m) values were higher in PiZZ when compared to other AATD genotypes. This study provides evidence that 2D-SWE is a suitable method for the assessment of liver disease in AATD. The newer methods of SWD and ATI require further evaluation in the context of AATD.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] LUNG DISEASE AND ALPHA1-ANTITRYPSIN DEFICIENCY
    PEDERSEN, JT
    WEEKE, B
    GEORG, J
    DANISH MEDICAL BULLETIN, 1969, 16 (09): : 283 - &
  • [42] Shear Wave Elastography for Evaluation of Liver Fibrosis
    Ferraioli, Giovanna
    Parekh, Parth
    Levitov, Alexander B.
    Filice, Carlo
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) : 197 - 203
  • [43] COMPARISON OF 2-D SHEAR WAVE ELASTOGRAPHY AND POINT SHEAR WAVE ELASTOGRAPHY FOR ASSESSING LIVER FIBROSIS
    Zhou, Xiaozhuan
    Rao, Jiawei
    Wu, Xukun
    Deng, Ronghai
    Ma, Yi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03): : 408 - 427
  • [44] Multisample Ultrasound Point Shear Wave Elastography of the Liver Repeatability and Agreement With Conventional Point Shear Wave Elastography
    Dillman, Jonathan R.
    Trout, Andrew T.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (12) : 2749 - 2756
  • [45] CHARACTERIZATION OF ALPHA1-ANTITRYPSIN IN INCLUSION-BODIES FROM LIVER IN ALPHA1-ANTITRYPSIN DEFICIENCY
    JEPPSSON, JO
    LARSSON, C
    ERIKSSON, S
    NEW ENGLAND JOURNAL OF MEDICINE, 1975, 293 (12): : 576 - 579
  • [46] Shear wave elastography and dispersion imaging in intestinal ultrasound in the setting of chronic diarrhea
    Ustuner, Evren
    JOURNAL OF CLINICAL ULTRASOUND, 2024, 52 (02) : 176 - 177
  • [47] Assessment of liver stiffness with shear wave elastography for hepatic AL amyloidosis
    Miki, Hirokazu
    Nakamura, Shingen
    Nakamura, Masafumi
    Sumitani, Ryohei
    Oura, Masahiro
    Sogabe, Kimiko
    Takahashi, Mamiko
    Maruhashi, Tomoko
    Harada, Takeshi
    Fujii, Shiro
    Nishio, Susumu
    Tomonari, Tetsu
    Abe, Masahiro
    CLINICAL LYMPHOMA MYELOMA & LEUKEMIA, 2021, 21 : S52 - S52
  • [48] Doppler ultrasound compared to shear wave elastography for assessment of liver cirrhosis
    Ellaban, Heba Said
    Afify, Sameh Abdel Mawgoud
    Abdelgawad, Mohamed Saied
    EGYPTIAN JOURNAL OF INTERNAL MEDICINE, 2024, 36 (01):
  • [49] The assessment of the applicability of shear wave elastography in modelling of the mechanical parameters of the liver
    Zmudzinska, Matylda
    Inglot, Marcin
    Zaleska-Dorobisz, Urszula
    Jankowski, Ludomir
    Swiatek-Najwer, Ewelina
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) : 59 - 64
  • [50] AUTOMATIC ASSESSMENT OF SHEAR WAVE ELASTOGRAPHY QUALITY AND MEASUREMENT RELIABILITY IN THE LIVER
    Pellot-Barakat, Claire
    Lefort, Muriel
    Chami, Linda
    Labit, Ymickael
    Frouin, Frederique
    Lucidarme, Olivier
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (04): : 936 - 943