Shear Wave Elastography and Shear Wave Dispersion Imaging in the Assessment of Liver Disease in Alpha1-Antitrypsin Deficiency

被引:3
|
作者
Schulz, Marten [1 ,2 ]
Kleinjans, Moritz [3 ,4 ,5 ]
Strnad, Pavel [3 ,4 ,5 ]
Demir, Muenevver [1 ,2 ]
Holtmann, Theresa M. [1 ,2 ]
Tacke, Frank [1 ,2 ]
Wree, Alexander [1 ,2 ]
机构
[1] Charite Univ Med Berlin, Dept Hepatol & Gastroenterol, Campus Virchow Klinikum CVK, D-13353 Berlin, Germany
[2] Charite Univ Med Berlin, Campus Charite Mitte CCM, D-13353 Berlin, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Gastroenterol Metab Dis & Intens Care, Med Clin 3, D-52074 Aachen, Germany
[4] European Reference Network ERN Rare Liver, Coordinating Ctr Alpha1 Antitrypsin Deficiency Re, D-52074 Aachen, Germany
[5] European Assoc Study Liver EASL, Registry Grp Alpha1 Liver, D-52074 Aachen, Germany
关键词
alpha1-antitrypsin deficiency (AATD); shear wave elastography (SWE); shear wave dispersion (SWD);
D O I
10.3390/diagnostics11040629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Liver affection of Alpha1-antitrypsin deficiency (AATD) can lead to cirrhosis and hepatocellular carcinoma (HCC). A noninvasive severity assessment of liver disease in AATD is urgently needed since laboratory parameters may not accurately reflect the extent of liver involvement. Preliminary data exist on two-dimensional shear wave elastography (2D-SWE) being a suitable method for liver fibrosis measurement in AATD. AATD patients without HCC were examined using 2D-SWE, shear wave dispersion imaging (SWD) and transient elastography (TE). Furthermore, liver steatosis was assessed using the controlled attenuation parameter (CAP) and compared to the new method of attenuation imaging (ATI). 29 AATD patients were enrolled, of which 18 had the PiZZ genotype, eight had PiMZ, two had PiSZ and one had a PiZP-Lowell genotype. 2D-SWE (median 1.42 m/S, range 1.14-1.83 m/S) and TE (median 4.8 kPa, range 2.8-24.6 kPa) values displayed a significant correlation (R = 0.475, p < 0.05). 2D-SWE, ATI (median 0.56 dB/cm/MHz, range 0.43-0.96 dB/cm/MHz) and CAP (median 249.5 dB/m, range 156-347 dB/m) values were higher in PiZZ when compared to other AATD genotypes. This study provides evidence that 2D-SWE is a suitable method for the assessment of liver disease in AATD. The newer methods of SWD and ATI require further evaluation in the context of AATD.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Alpha1-Antitrypsin Deficiency A Cause of Chronic Liver Disease
    Manne, Vignan
    Kowdley, Kris, V
    CLINICS IN LIVER DISEASE, 2020, 24 (03) : 483 - +
  • [22] Shear Wave Imaging of Breast Tissue by Color Doppler Shear Wave Elastography
    Yamakoshi, Yoshiki
    Nakajima, Takahito
    Kasahara, Toshihiro
    Yamazaki, Mayuko
    Koda, Ren
    Sunaguchi, Naoki
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (02) : 340 - 348
  • [23] Assessment of Liver Stiffness by Shear Wave Elastography in Liver Transplant Recipients
    Senkerikova, Renata
    Gottfriedova, Halima
    Sticova, Eva
    Frankova, Sona
    Fronek, Jiri
    Trunecka, Pavel
    Spicak, Julius
    Sperl, Jan
    GASTROENTEROLOGY, 2015, 148 (04) : S1005 - S1005
  • [24] ENDOSCOPIC ULTRASOUND SHEAR WAVE ELASTOGRAPHY FOR LIVER FIBROSIS ASSESSMENT
    Chin, Jerry Yung-Lun
    Vargas, Eric
    Abu Dayyeh, Barham
    Garimella, Vishal
    Storm, Andrew
    Law, Ryan
    Levy, Michael
    Chandrasekhara, Vinay
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB833 - AB834
  • [25] ASSESSMENT OF LIVER STIFFNESS BY SHEAR WAVE ELASTOGRAPHY IN LIVER TRANSPLANT RECIPIENTS
    Gottfriedova, Halima
    Senkerikova, Renata
    Sticova, Eva
    Frankova, Sona
    Fronek, Jiri
    Trunecka, Pavel
    Spicak, Julius
    Sperl, Jan
    TRANSPLANT INTERNATIONAL, 2015, 28 : 139 - 139
  • [26] Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow-up of pediatric liver grafts
    Cetinic, Ivan
    de Lange, Charlotte
    Bostroem, Hakan
    Ekvall, Nils
    Bennet, William
    Lagerstrand, Kerstin
    Hebelka, Hanna
    PEDIATRIC TRANSPLANTATION, 2023, 27 (07)
  • [27] LIVER REPLACEMENT FOR ALPHA1-ANTITRYPSIN DEFICIENCY
    PUTNAM, CW
    PORTER, KA
    PETERS, RL
    ASHCAVAI, M
    REDEKER, AG
    STARZL, TE
    SURGERY, 1977, 81 (03) : 258 - 261
  • [28] Liver stiffness by shear-wave elastography in Alcoholic Liver Disease
    Vonghia, Luisa
    Verlinden, Wim
    Cauwenberghs, Laura
    Steinhauser, Anton
    Van Dongen, Jurgen L.
    Van Marck, Veerle
    Pelckmans, Paul A.
    Michielsen, Peter P.
    Francque, Sven M.
    HEPATOLOGY, 2013, 58 : 958A - 958A
  • [29] What is the role of measuring shear wave dispersion using shear wave elastography in pancreatic parenchyma?
    Suzuki, Hirotaka
    Kawashima, Hiroki
    Ohno, Eizaburo
    Ishikawa, Takuya
    Hashimoto, Senju
    Nakamura, Masanao
    Miyahara, Ryoji
    Ishigami, Masatoshi
    Hirooka, Yoshiki
    Fujishiro, Mitsuhiro
    JOURNAL OF MEDICAL ULTRASONICS, 2020, 47 (04) : 575 - 581
  • [30] What is the role of measuring shear wave dispersion using shear wave elastography in pancreatic parenchyma?
    Hirotaka Suzuki
    Hiroki Kawashima
    Eizaburo Ohno
    Takuya Ishikawa
    Senju Hashimoto
    Masanao Nakamura
    Ryoji Miyahara
    Masatoshi Ishigami
    Yoshiki Hirooka
    Mitsuhiro Fujishiro
    Journal of Medical Ultrasonics, 2020, 47 : 575 - 581