Influence of wall luminance and uniformity on preferred task illuminance

被引:24
|
作者
Chraibi, Sanae [1 ,2 ]
Crommentuijn, Lisan [1 ]
van Loenen, Evert [2 ,3 ]
Rosemann, Alexander [2 ]
机构
[1] Philips Lighting, High Tech Campus 7, NL-5656 AE Eindhoven, Netherlands
[2] Eindhoven Univ Technol, Eindhoven, Netherlands
[3] Royal Philips, Eindhoven, Netherlands
关键词
Lighting; Open office; Personal control; Brightness perception; LAMP SPECTRUM; OFFICES; PERFORMANCE; ENVIRONMENT; BRIGHTNESS; APPRAISAL;
D O I
10.1016/j.buildenv.2017.02.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Literature suggests an influence of the luminance from non-horizontal surfaces in our visual field on our visual and psychological assessments of an office space. These assessments are believed to directly relate to our expressed preferred task illuminances. This paper describes an evaluation in a mock-up office, wherein wall conditions with a non-uniform and a more uniform light distribution of 3 different average luminance levels have been evaluated regarding their effect on users' preferred task illuminance. Each condition is evaluated starting from three different initial desk illuminances. For all test conditions, a wall with a non-uniformly distributed average luminance of 200 cd/m(2) lead to significantly lower selected desk illuminances than a uniformly lit wall with the same average luminance level. In all cases, preferred task illuminances set were significantly lower when offering the lowest starting level for dimming of 300 lx. The range of preferred illuminance levels between subjects was also found to be smaller for dimming with the starting level of 300 lx at desk level. The study suggests that when providing users with personal control they will control the total perceived brightness in their visual field, even though they are only directly affecting their task illuminance level. Triggering the selection of lower preferred illuminance levels due to a personal control starting level of 300 lx, will positively influence the energy used for lighting. The smaller range of preferred illuminance levels between subjects at the starting of 300 lx could reduce the risk of lighting preference related conflict between people. However, more research is needed to confirm that these smaller differences are also perceivable by users. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:24 / 35
页数:12
相关论文
共 50 条
  • [41] Study of illuminance uniformity for LED illumination light field
    Harbin Normal University, Harbin 150025, China
    不详
    Guangxue Jishu, 2007, SUPPL. (327-328):
  • [42] Simulation and Analysis of Uniformity of Illuminance in Indoor VLC System
    Priyanka
    Singh, Maninder Lal
    2018 6TH EDITION OF INTERNATIONAL CONFERENCE ON WIRELESS NETWORKS & EMBEDDED SYSTEMS (WECON), 2018, : 142 - 147
  • [43] EFFECT OF ABERRATIONS OF OPTICAL ILLUMINATION SYSTEMS ON THE ILLUMINANCE UNIFORMITY
    RODIONOV, SA
    SHEKHONIN, AA
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1990, 57 (01): : 27 - 29
  • [44] ASSESSING UNIFORMITY OF ILLUMINANCE BASED ON A LED TUNABLE SYSTEM
    Hu, Y.
    Luo, M. R.
    Yang, Y.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 247 - 252
  • [45] INFLUENCE OF VESTIBULAR STIMULATION AND DISPLAY LUMINANCE ON PERFORMANCE OF A COMPENSATORY TRACKING TASK
    GILSON, RD
    GUEDRY, FE
    BENSON, AJ
    AEROSPACE MEDICINE, 1970, 41 (11): : 1231 - &
  • [46] Method for Evaluating the Uniformity of Projector Luminance Distribution
    Sakai, Naoki
    Kishi, Yumiko
    Suino, Tom
    Hino, Makoto
    THIRTEENTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION 2017, 2017, 10338
  • [47] The relationship between luminance uniformity and brightness perception
    Ngai, PY
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 2000, 29 (01): : 41 - +
  • [48] DESIGN OF ROAD LIGHTING FOR GIVEN LUMINANCE AND UNIFORMITY
    VERMEULEN, J
    KNUDSEN, B
    PHILIPS TECHNICAL REVIEW, 1968, 29 (10): : 299 - +
  • [49] Luminance Uniformity of Integrating Sphere Light Source
    Liu, Liying
    Zheng, Feng
    Zhu, Lingxi
    Li, Ye
    Huan, Kewei
    Shi, Xiaoguang
    Liu, Guojun
    2015 INTERNATIONAL CONFERENCE ON OPTOELECTRONICS AND MICROELECTRONICS (ICOM), 2015, : 265 - 268
  • [50] A new method for testing luminance uniformity of OLED
    Changchun Institute of Optics, Fine Mechanics and Physics, Changchun 130033, China
    不详
    不详
    Guangxue Jishu, 2007, 1 (41-43+47): : 41 - 43