Influence of wall luminance and uniformity on preferred task illuminance

被引:24
|
作者
Chraibi, Sanae [1 ,2 ]
Crommentuijn, Lisan [1 ]
van Loenen, Evert [2 ,3 ]
Rosemann, Alexander [2 ]
机构
[1] Philips Lighting, High Tech Campus 7, NL-5656 AE Eindhoven, Netherlands
[2] Eindhoven Univ Technol, Eindhoven, Netherlands
[3] Royal Philips, Eindhoven, Netherlands
关键词
Lighting; Open office; Personal control; Brightness perception; LAMP SPECTRUM; OFFICES; PERFORMANCE; ENVIRONMENT; BRIGHTNESS; APPRAISAL;
D O I
10.1016/j.buildenv.2017.02.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Literature suggests an influence of the luminance from non-horizontal surfaces in our visual field on our visual and psychological assessments of an office space. These assessments are believed to directly relate to our expressed preferred task illuminances. This paper describes an evaluation in a mock-up office, wherein wall conditions with a non-uniform and a more uniform light distribution of 3 different average luminance levels have been evaluated regarding their effect on users' preferred task illuminance. Each condition is evaluated starting from three different initial desk illuminances. For all test conditions, a wall with a non-uniformly distributed average luminance of 200 cd/m(2) lead to significantly lower selected desk illuminances than a uniformly lit wall with the same average luminance level. In all cases, preferred task illuminances set were significantly lower when offering the lowest starting level for dimming of 300 lx. The range of preferred illuminance levels between subjects was also found to be smaller for dimming with the starting level of 300 lx at desk level. The study suggests that when providing users with personal control they will control the total perceived brightness in their visual field, even though they are only directly affecting their task illuminance level. Triggering the selection of lower preferred illuminance levels due to a personal control starting level of 300 lx, will positively influence the energy used for lighting. The smaller range of preferred illuminance levels between subjects at the starting of 300 lx could reduce the risk of lighting preference related conflict between people. However, more research is needed to confirm that these smaller differences are also perceivable by users. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:24 / 35
页数:12
相关论文
共 50 条
  • [31] REFERENCE LIGHT-SOURCE FOR LUMINANCE AND ILLUMINANCE PHOTOMETRY
    NILSSON, TH
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1981, 13 (01): : 18 - 19
  • [32] Illuminance uniformity in obstructed LED surgical lighting
    Zhou, H.
    Ding, R.
    Qin, J.
    Pan, Y.
    Wang, M.
    LIGHTING RESEARCH & TECHNOLOGY, 2022, 54 (08) : 819 - 828
  • [33] Preferred Illuminance and Color Temperature in Creative Works
    Taniguchi, Yuka
    Miki, Mitsunori
    Hiroyasu, Tomoyuki
    Yoshimi, Masato
    2011 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2011, : 3255 - 3260
  • [34] Preference for luminance uniformity of refrigerator lighting
    Jeong, Kyeong Ah
    You, Chanyang
    Suk, Hyeon-Jeong
    COLOR RESEARCH AND APPLICATION, 2021, 46 (01): : 146 - 154
  • [35] Research on the Preferred Illuminance in Office Environments Based on EEG
    Tong, Li
    Liu, Nian
    Hu, Songtao
    Lu, Mingli
    Zheng, Yuxi
    Ma, Xiaohui
    BUILDINGS, 2023, 13 (02)
  • [36] Adaptive display luminance for viewing smartphones under low illuminance
    Na, Nooree
    Suk, Hyeon-Jeong
    OPTICS EXPRESS, 2015, 23 (13): : 16912 - 16920
  • [37] Reference luminous solar constant and solar luminance for illuminance calculations
    Darula, S
    Kittler, R
    Gueymard, CA
    SOLAR ENERGY, 2005, 79 (05) : 559 - 565
  • [38] Luminance and illuminance analysis of roads using image processing technique
    Kayakus, Mehmet
    Uncu, Ismail Serkan
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (10): : 283 - 285
  • [39] Exploring Horizontal and Vertical Illuminance Daylighting Uniformity Metrics
    Rogers, Zack
    Clevenger, Caroline
    Zivkovich, Brik
    Abdallah, Moatassem
    CONSTRUCTION RESEARCH CONGRESS 2016: OLD AND NEW CONSTRUCTION TECHNOLOGIES CONVERGE IN HISTORIC SAN JUAN, 2016, : 2382 - 2391
  • [40] The retinal illuminance in trolands caused by luminance and color of PC monitors
    Suaste-Gómez, E
    Zúñiga-López, A
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1734 - 1735