An up to 5-year clinical evaluation of posterior in-ceram CAD/CAM core crowns

被引:0
|
作者
Bindl, A [1 ]
Mörmann, WH [1 ]
机构
[1] Univ Zurich, Clin Div Aesthet & Comp Restorat, Dept Prevent Dent Periodontol & Cariol, Ctr Dent & Oral Med, CH-8006 Zurich, Switzerland
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the clinical performance of posterior CAD/CAM-generated In-Ceram Alumina and In-Ceram Spinell core crowns. Materials and Methods: Nineteen InCeram Spinell core crowns (four premolars and 15 molars) and 24 In-Ceram Alumina core crowns (two premolars and 22 molars) in 21 patients were examined using modified USPHS criteria at baseline and after a mean service time of 39 +/- 11 months. The crown copings were machined from Vitablocs In-Ceram Alumina and Vitablocs In-Ceram Spinell using the Cerec 2 CAD/CAM system. Results: Two molar In-Ceram Alumina core crowns fractured after respective service times of 14 and 17 months in the same patient. The Kaplan-Meier survival rate regarding fracture of the ceramic was 92% for In-Ceram Alumina and 100% for In-Ceram Spinell. At the follow-up examination, 80% alpha ratings and 18% beta ratings for In-Ceram Alumina core crowns and 84% alpha ratings and 15% beta ratings for In-Ceram Spinell core crowns were recorded. Conclusion: Despite the two fractures, the clinical quality of CAD/CAM-generated In-Ceram Alumina and In-Ceram Spinell posterior crowns was excellent. Within the limitations of this study, both types of crowns appeared to be feasible.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [41] Eight-year clinical evaluation of 109 Cad/Cam inlays.
    Cerutti, A
    Venturi, G
    Putignano, A
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 335 - 335
  • [42] THE CAD HIP-ARTHROPLASTY - 5-YEAR TO 10-YEAR FOLLOW-UP
    THOMAS, BJ
    SALVATI, EA
    SMALL, RD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05): : 640 - 646
  • [43] Frictional Telescopic Crowns in Severely Reduced Dentitions: A 5-Year Clinical Outcome Study
    Szentpetery, Viola
    Lautenschlaeger, Christine
    Setz, Juergen M.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (03) : 217 - 220
  • [44] Zirconia crowns cemented on titanium bars using CAD/CAM: a five-year follow-up prospective clinical study of 9 patients
    Scarano, Antonio
    Stoppaccioli, Marco
    Casolino, Tommaso
    BMC ORAL HEALTH, 2019, 19 (01)
  • [45] 5-YEAR CLINICAL-STUDY OF COMPOSITE RESINS IN POSTERIOR TEETH
    HEYMANN, HO
    LEONARD, RH
    WILDER, AD
    MAY, KN
    JOURNAL OF DENTAL RESEARCH, 1987, 66 : 166 - 166
  • [46] Evaluation of the survival rate of short implants placed in the posterior atrophic mandible: 5-year clinical study
    Hakobyan, Gagik
    Jilavyan, Ashot
    Khachatryan, Gagik
    Tunyan, Gekham
    Mathevosyan, Davit
    Ghambaryan, Naira
    QUINTESSENCE INTERNATIONAL, 2022, 53 (08): : 690 - 696
  • [47] CAD/CAM-fabricated ceramic implant-supported single crowns made from lithium disilicate: Final results of a 5-year prospective cohort study
    Spies, Benedikt Christopher
    Pieralli, Stefano
    Vach, Kirstin
    Kohal, Ralf-Joachim
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 876 - 883
  • [48] A 5-year clinical evaluation of Norplant® implants in Senegal
    Ba, MG
    Moreau, JC
    Sokal, D
    Dunson, R
    Dao, B
    Kouedou, D
    Diadhiou, F
    CONTRACEPTION, 1999, 59 (06) : 377 - 381
  • [49] TRICHINOSIS - 5-YEAR SEROLOGIC AND CLINICAL FOLLOW-UP
    COX, PM
    SCHULTZ, MG
    KAGAN, IG
    PREIZLER, J
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 1969, 89 (06) : 651 - &
  • [50] A 3-Year Clinical Evaluation of Endodontically Treated Posterior Teeth Restored with Resin Nanoceramic Computer-Aided Design/Computer-Aided Manufacture (CAD/CAM)-Fabricated Partial Crowns
    Zhang, Lei
    Hou, Xiao-Xia
    Aishan, Maihefuzi
    Tian, Meng-Ting
    He, Hui-Yu
    MEDICAL SCIENCE MONITOR, 2022, 28