An up to 5-year clinical evaluation of posterior in-ceram CAD/CAM core crowns

被引:0
|
作者
Bindl, A [1 ]
Mörmann, WH [1 ]
机构
[1] Univ Zurich, Clin Div Aesthet & Comp Restorat, Dept Prevent Dent Periodontol & Cariol, Ctr Dent & Oral Med, CH-8006 Zurich, Switzerland
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the clinical performance of posterior CAD/CAM-generated In-Ceram Alumina and In-Ceram Spinell core crowns. Materials and Methods: Nineteen InCeram Spinell core crowns (four premolars and 15 molars) and 24 In-Ceram Alumina core crowns (two premolars and 22 molars) in 21 patients were examined using modified USPHS criteria at baseline and after a mean service time of 39 +/- 11 months. The crown copings were machined from Vitablocs In-Ceram Alumina and Vitablocs In-Ceram Spinell using the Cerec 2 CAD/CAM system. Results: Two molar In-Ceram Alumina core crowns fractured after respective service times of 14 and 17 months in the same patient. The Kaplan-Meier survival rate regarding fracture of the ceramic was 92% for In-Ceram Alumina and 100% for In-Ceram Spinell. At the follow-up examination, 80% alpha ratings and 18% beta ratings for In-Ceram Alumina core crowns and 84% alpha ratings and 15% beta ratings for In-Ceram Spinell core crowns were recorded. Conclusion: Despite the two fractures, the clinical quality of CAD/CAM-generated In-Ceram Alumina and In-Ceram Spinell posterior crowns was excellent. Within the limitations of this study, both types of crowns appeared to be feasible.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [31] Clinical Outcomes of Monolithic Zirconia Crowns with CAD/CAM Technology. A 1-Year Follow-Up Prospective Clinical Study of 65 Patients
    Konstantinidis, Ioannis
    Trikka, Dimitra
    Gasparatos, Spyridon
    Mitsias, Miltiadis E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (11)
  • [33] Clinical Evaluation of Three Types of CAD/CAM Inlay/Onlay Materials After 1-Year Clinical Follow Up
    Aslan, Yilmaz Umut
    Coskun, Elif
    Ozkan, Yasemin
    Dard, Michel
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2019, 27 (03): : 131 - 140
  • [34] Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD-CAM systems
    Ahn, Jong-Ju
    Bae, Eun-Bin
    Lee, Jin-Ju
    Choi, Jae-Won
    Jeon, Young-Chan
    Jeong, Chang-Mo
    Yun, Mi-Jung
    Lee, So-Hyoun
    Lee, Kyu-Bok
    Huh, Jung-Bo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 239 - 247
  • [35] Clinical performance of two different CAD/CAM-fabricated ceramic crowns: 2-Year results
    Seydler, Bodo
    Schmitter, Marc
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (02): : 212 - 216
  • [36] SINGLE CROWNS WITH CAD/CAM-FABRICATED COPINGS FROM TITANIUM: 6-YEAR CLINICAL RESULTS
    Hey, Jeremias d
    Beuer, Florian
    Bensel, Tobias
    Boeckler, Arne F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02): : 150 - 154
  • [37] Five-year clinical evaluation of CAD-CAM ceramic restorations
    Essig, ME
    Isenberg, BP
    Leinfelder, KF
    Liu, PR
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1201 - 1201
  • [38] Ten-year clinical evaluation of 109 Cad/Cam inlays.
    Cerutti, A
    Venturi, G
    Giaconelli, G
    Putignano, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B236 - B236
  • [39] Zirconia crowns cemented on titanium bars using CAD/CAM: a five-year follow-up prospective clinical study of 9 patients
    Antonio Scarano
    Marco Stoppaccioli
    Tommaso Casolino
    BMC Oral Health, 19
  • [40] Clinical evaluation of CAD/CAM ceramic restorations: 6-year report
    Pallesen, U
    CAD/CIM IN AESTHETIC DENTISTRY, 1996, : 241 - 253